The KITOZER 250kW central solar inverter is a three-phase, transformerless grid-tie inverter designed for utility-scale ground-mount and large commercial rooftop PV plants. It accepts the DC output of a 1000V or 1500V PV array from a combiner box and delivers clean 400V AC to a step-up transformer. The cabinet is built for outdoor installation and can be paralleled up to dozens of units on a common MV feeder, making it a cost-effective choice for 5MW to 50MW solar farms.
Table of Contents
ToggleProduct Overview
KITOZER designs the 250kW central inverter around a three-level NPC topology with LCL output filtering, achieving 98.7 percent maximum efficiency. Two independent MPPTs accept the output of two array sections, and the integrated DC switch, DC SPD, AC SPD, and AC breaker remove the need for a separate AC and DC distribution cabinet. The controller follows the local grid code for voltage and frequency ride-through, reactive power support, and power factor control. A local HMI and a web server give operators live access to power, energy, and fault logs, and the Modbus TCP or IEC 61850 port integrates the inverter into the plant SCADA.
Technical Specifications
Rated output 250kW, three phase 400V. PV input max 300kW, 2 MPPTs, MPPT range 500 to 1500V. Max input voltage 1500V. Max input current 400A. Maximum efficiency 98.7 percent, European efficiency 98.5 percent. THD less than 3 percent. Power factor 0.9 adjustable. Protection IP54 outdoor. Cooling redundant smart fans. Communication Modbus TCP, IEC 61850, optional fiber. Dimensions 1400 x 900 x 2000 millimeters, weight 950 kilograms. Certifications IEC 62109, CE, GB/T 19964, IEEE 1547, VDE 4110. KITOZER five-year warranty, extendable to ten years.
Application Scenarios
The 250kW central inverter is used in 5MW to 50MW utility solar farms, in large warehouse rooftop arrays, and in solar-plus-storage plants that need a single point of DC to AC conversion. It pairs with a 1250kVA or 2500kVA step-up transformer on the same skid, delivering a compact MV skid to the site. Independent power producers choose central inverters over string inverters for large sites because the balance of system cost per watt is lower when fewer conversion points are needed.
Key Advantages
Centralized topology reduces the number of conversion points and the associated cabling, which lowers balance of system cost on large sites. The 1500V DC support matches the latest bifacial module and tracker generation, reducing line losses. Integrated DC and AC switchgear removes the need for a separate distribution cabinet, saving skid space and commissioning time. Redundant fans keep the inverter running even if one fan fails, which matters on remote sites where a service truck takes days to reach.
Installation and Maintenance
Lift the cabinet with the dedicated top lugs and anchor it to a reinforced concrete plinth with four M16 bolts. Leave 1000 millimeters on the hinge side for door opening and 500 millimeters on the exhaust side. Commissioning requires a KITOZER engineer for the first unit to tune the grid code and the protection settings. Annual service includes filter cleaning, fan bearing check, and a thermal scan of the busbar joints. Keep spare fuses and a spare communication board on site to minimize downtime during the warranty period.
Quality, Warranty and Delivery
KITOZER burns in each 250kW central inverter for six hours at rated power, cycles the redundant fans, and runs a full grid-code test on a regenerative grid simulator before release. The cabinet ships on a steel skid with a wooden crate, a moisture barrier, and desiccant, and includes a factory test report, a signed protection settings sheet, a spare communication board, and a USB recovery drive. For multi-megawatt plants, KITOZER offers factory witness testing and a staged shipment schedule so units arrive in the order they will be commissioned. The five-year warranty covers the power stage, controller, and cooling, and can be extended to ten years with a 48-hour on-site response guarantee. KITOZER keeps a spare 250kW unit on call at each regional hub, so a total failure can be swapped out within a week and the plant avoids availability penalties. Spare fuses and fan filters are stocked on site at large plants as part of the recommended O and M package.
Configuration and Ordering. KITOZER supplies each unit with the options specified at order placement, including the communication protocol, protection level, mounting orientation, and labeling language. Optional accessories such as external disconnect switches, surge protection kits, spare fuse sets, wall brackets, and remote monitoring gateways are available at a discount when ordered together with the main unit. The factory provides a final dimension and wiring drawing for customer approval before production starts, and the approved drawing becomes the manufacturing specification. Standard packaging is suitable for sea freight, and KITOZER can arrange air freight for urgent replacement orders on request. Every unit ships with a factory test report, a quick-start guide, and a bag of spare cable glands.
Price
From $18,800 per unit. Contact KITOZER for multi-megawatt project pricing and extended warranty terms.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com