Table of Contents
ToggleProduct Overview
The KITOZER 250kW liquid cooled PCS is a utility grade power conversion cabinet for grid scale battery energy storage plants. Liquid cooling keeps IGBT junction temperatures tight, which allows the cabinet to deliver 250 kW continuously at 50 degrees ambient without derating. The PCS supports both grid following and grid forming control modes, and it can provide virtual synchronous generator inertia to weak grids. A 10 inch touch screen and redundant communication ports make the unit ready for SCADA integration from day one.
Technical Specifications
AC side: three phase 400 V, 50 or 60 Hz, 250 kW continuous. DC side: 600 to 1500 Vdc battery, 400 A maximum. Efficiency 98.5 percent peak, 98 percent European. THDi less than 2 percent, power factor adjustable 0.8 to 0.8. Islanding and anti-islanding compliant with IEEE 1547, VDE 0126, GB/T. Communication: dual Ethernet, CAN, Modbus TCP, IEC 61850, optional 4G. Cooling: liquid cooled with redundant coolant loop. Protection: DC over voltage, AC over voltage, islanding, over temperature, arc fault, smoke detection. Enclosure IP54, weight 850 kg, dimensions 1200 by 900 by 2000 mm. Standards CE, IEC 62109, KITOZER 5 year warranty.
Application Scenarios
The 250 kW PCS is the standard building block for 20 ft containerized storage systems rated at 1 MWh, where four PCS units pair with a 4 MWh battery array. It is also deployed at utility scale solar plus storage plants, wind farm firming installations, and industrial parks that need multi megawatt peak shaving. The liquid cooled design is preferred in desert and tropical climates where air cooled PCS units would derate significantly.
Advantages and Features
Liquid cooling improves power density by 30 percent compared with air cooled alternatives and reduces acoustic noise to below 75 dB(A), which matters in urban installations. The grid forming function provides synthetic inertia, frequency response, and voltage support, making the PCS eligible for ancillary service markets. Redundant coolant loops and communication ports ensure the unit stays online even if one loop or port fails. A built in battery management interface supports all mainstream lithium iron phosphate rack vendors.
Installation and Maintenance
The cabinet requires a 400 V feeder with a 630 A MCCB and a separate earth electrode. Connect the DC side to the battery array via a 600 A DC breaker, and the communication cable to the SCADA master. Check coolant level monthly and top up with the specified glycol mixture only. Annual maintenance includes heat exchanger cleaning, IGBT torque check, and firmware update. Keep one spare coolant pump on site.
Price
From $18,800 per unit. Contact plus 86 13922289957 for 1 MWh container bundle pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com