KITOZER 250kW Open Frame Diesel Generator For Industrial Plant

The KITOZER 250 kW open frame diesel generator is a heavy industrial standby unit delivering 312.5 kVA for manufacturing plants, large warehouses, shopping malls, and district water pumping stations. Powered by a six-cylinder or eight-cylinder turbocharged aftercooled diesel engine and matched to a Class H brushless alternator with permanent magnet excitation, the set handles large motor starting, welding transformer loads, and non-linear UPS loads with stable voltage. The reinforced skid includes forklift pockets and lifting eyes, and supports an optional integrated 800 L sub-base fuel tank for half a day of runtime without external supply.

Technical Specifications

Standby 275 kW (343.75 kVA), prime 250 kW (312.5 kVA), 400V 50Hz three-phase, power factor 0.8. Engine: water-cooled, turbocharged, aftercooled, 1500 rpm, electronic fuel injection. Alternator: brushless, PMG excitation, AVR, class H, IP23, 2/3 pitch winding for harmonic suppression. Controller: deep-sea DSE8610 or ComAp IntiVision, color LCD, Modbus TCP, SNMP, event log. Circuit breaker: 630A air circuit breaker. Battery 24V 200Ah. Dimensions approximately 3600 x 1200 x 1800 mm, dry weight 4500 to 5200 kg. Fuel consumption at 75 percent load around 55 L per hour.

Key Advantages

With PMG excitation, the alternator sustains 300 percent short-circuit current for 10 seconds, allowing upstream breakers to trip reliably during fault conditions. The 2/3 pitch winding reduces neutral current and harmonic distortion caused by VFDs and UPS systems, making the set suitable for modern factories with high electronic load content. The engine is equipped with a crankcase breather, fuel-water separator with sensor, and dual fuel filter for long service intervals. The control panel supports paralleling signals, so the unit can later be tied into a multi-generator plant without replacing the controller.

Applications

The 250 kW class is a standard choice for automotive component plants, pharmaceutical factories, food and beverage processing lines, cold storage warehouses, and medium-sized shopping malls. It powers HVAC chillers, sprinkler pumps, lifts, emergency lighting, and selected production lines during extended grid outages. Water treatment plants, sewage pumping stations, and mining sites in remote regions use the set as prime power, running 12 to 24 hours per day. Large office blocks and hospitals also specify this rating for life-safety loads plus a portion of normal occupancy loads.

Installation and Maintenance

Foundation design must account for the 5 tonne mass and dynamic reaction from the engine. Use a reinforced concrete plinth at least 300 mm thick and 400 mm larger than the skid on all sides, with spring-type anti-vibration mounts sized for 1.5 times the static weight. Generator room ventilation must remove approximately 25000 kJ per minute of heat; size inlet louvers and outlet fans accordingly. The exhaust system uses a 6-inch insulated pipe, industrial-grade flexible bellows, and an optional spark arrestor. Fuel supply should come from an external day tank mounted above the generator, with a return line and leak detection.

Maintenance intervals: engine oil and filter every 250 hours, fuel filter every 500 hours, air filter every 1000 hours, coolant every 2 years, valve adjustment every 3000 hours. Conduct a full load bank test annually at 100 percent load for 2 hours to confirm exhaust temperature, oil pressure, and voltage regulation remain within factory limits. Inspect the alternator brushes (if any), AVR connections, and power cable terminals for tightness every 6 months. KITOZER recommends signing a yearly service contract for critical sites, including two preventive visits and 24/7 telephone support.

Packaging and Shipping

The open frame generator is wrapped in stretch film, protected with foam on gauges and alternator, and strapped to a fumigated steel skid with lifting eyes. KITOZER factory-load-banks every unit and provides a performance certificate before shipment. Export documents include CE certificate, factory test report, commercial invoice, packing list, and origin certificate. KITOZER can arrange container loading, CIF delivery, and engineer commissioning on site.

Quality Assurance and Warranty

Every KITOZER product undergoes a strict factory inspection process before shipment. The engine is run in and load-tested, the alternator winding resistance and insulation are measured, the control panel is functionally checked, and the complete set is operated under load bank for at least one hour. KITOZER provides a 12-month warranty from shipment or 1000 running hours, whichever comes first, covering manufacturing defects in engine, alternator, and control panel. Spare parts, filters, belts, and fuses are stocked for rapid dispatch. The KITOZER technical team provides remote troubleshooting support over email, WeChat, or WhatsApp, and can dispatch an engineer to site for critical projects.

KITOZER engineering can tailor the set to specific site conditions: cold climate kits with jacket water heater, oil pan heater, and battery blankets; tropical kits with larger radiator and desert-grade air filters; coastal kits with C5-M paint and anti-corrosion anodes; and emission-compliant kits for regulated markets. The factory also offers extended warranty, annual service contracts, and remote monitoring subscriptions that stream runtime, fuel level, and alarms to a cloud dashboard.

Price

From $38,000 per unit for the 250 kW open frame set. Contact KITOZER for engine brand selection, alternator brand, AMF cabinet, and fuel tank options. Tel/WeChat: +86 13922289957.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com