The KITOZER 250kW utility string inverter is a high power three phase inverter for utility scale ground mount solar plants. With twelve MPPT channels and a 1500 Vdc design, it supports up to 375 kWp of photovoltaic modules per unit. The inverter is housed in a weatherproof cabinet with forced air cooling, a 10 inch touch screen, and redundant communication ports. Multiple units are paralleled at the LV switchboard to form plants from 1 MW to hundreds of MW. The cabinet includes a built in DC switch, type 2 surge protection, and arc fault detection.
Technical Specifications
Input: three phase 400 V, 50 or 60 Hz. Output: 250 kW continuous. DC side: twelve MPPT, 500 to 1500 Vdc, 26 A per MPPT. Maximum DC input 375 kW. Efficiency 98.7 percent peak, 98.3 percent European. THDi less than 2 percent, power factor adjustable 0.8 to 0.8. Islanding compliant with VDE 0126, G99, EN 50549, IEEE 1547. Communication: dual Ethernet, Modbus TCP, IEC 61850, optional 4G. Protection: DC switch, type 2 surge, arc fault. Enclosure IP65, weight 280 kg, dimensions 1000 by 800 by 1800 mm. Operating temperature minus 25 to plus 60 degrees. Noise level below 65 dB(A). Standards CE, IEC 62109, KITOZER 5 year warranty.
Application Scenarios
The 250 kW string inverter is the standard building block for utility scale ground mount solar plants from 1 MW to 100 MW. It is also used at floating solar plants, agrivoltaics, and solar plus storage installations. The 1500 Vdc design reduces cable losses and combiner box count, which is critical for large ground mount arrays spanning tens of hectares. It is also specified at utility scale solar farms, at utility owned distributed generation sites, and at large industrial campuses that want to generate their own power.
Advantages and Features
Twelve MPPT channels handle complex string layouts and partial shading from terrain. The 1500 Vdc design reduces balance of system cost by up to 20 percent compared with 1000 V systems. Redundant fans and communication ports ensure high availability. The cloud portal shows per string yield and supports automated SCADA integration. The inverter provides reactive power support and frequency response, making it eligible for grid service revenue. The dual Ethernet ports support redundant communication.
Installation and Maintenance
Place the inverter on a level concrete plinth in a ventilated outdoor enclosure. Connect the DC strings via the integrated DC switch, and the AC side to the LV switchboard via a 630 A three phase MCCB. Connect the dual Ethernet to the plant SCADA network. Maintenance includes cleaning air filters every six months and inspecting DC connectors annually. Fans are field replaceable. The unit carries a 5 year warranty.
Reliability and Quality
Each inverter is burned in for 24 hours at full load. The enclosure passes salt spray and vibration tests. The redundant fans are rated for 50,000 hours. The KITOZER cloud portal stores per string yield and fault logs for twelve months. Regional service partners provide on site support within 48 hours. The unit carries a 5 year warranty with a 10 year extension available.
Price
From $12,800 per unit. Contact plus 86 13922289957 for utility scale project pricing. Lead time 30 days.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com