1. Overview

KITOZER KTR-B51000D is a 2 V 1000 Ah deep-cycle VRLA battery used in center UPS, DC panels and telecom power back-up to store energy. Cells are series-connected into 48 V, 240 V or 336 V strings; on mains loss they discharge instantly to carry the UPS and critical loads while the generator starts and transfer completes. Deep-cycle means it tolerates deeper charge-discharge cycling than a standby float battery, suiting frequent outages or long autonomy.

The VRLA valve-regulated sealed design is leak-free, needs no watering and mounts upright on racks or in cabinets with little maintenance. KTR-B51000D uses high-tin grids and tight assembly for low self-discharge, good high-current discharge and long cycle life. Each cell has a safety vent that releases on overcharge and seals under normal use. Voltage sense terminals connect to a battery monitor for live per-cell voltage and internal resistance, flagging weak cells early.

In power and UPS systems, the battery string is the last line of defense: a great UPS is useless with dead batteries. 2 V 1000 Ah cells, large and consistent, dominate medium-to-large UPS and DC operating power. KTR-B51000D is tiered by capacity and design life; when supplied as a string, same-batch, matched internal resistance is emphasized for balanced discharge.

2. Key Features

2V 1000Ah deep cycle

  • 2 V cell, 1000 Ah.
  • Deep-cycle, tolerates deep discharge.
  • Strong high-current discharge.
  • Series strings.

VRLA sealed

  • Valve-regulated, leak-free.
  • No watering.
  • Indoor upright mount.
  • Safe relief valve.

Long life, consistent

  • High-tin grid, low self-discharge.
  • Tight assembly.
  • Long design cycle life.
  • Same-batch matched strings.

Monitoreable

  • Per-cell sense terminals.
  • Connects to a battery monitor.
  • Voltage / resistance / temperature.
  • Early weak-cell warning.

3. Specifications

项目 KTR-B51000D(标准) KTR-B51000D-L(长寿命) KTR-B51000D-H(高导)
额定电压 2V 2V 2V
额定容量(10hr) 1000Ah 1000Ah 1000Ah
设计浮充寿命 10~12年 15年 10~12年
板栅合金 高锡铅钙 高锡铅钙 高导焊式
自放电(月) ≤3% ≤3% ≤3%
充电电压 2.27~2.30V/单体 2.27~2.30V/单体 2.27~2.30V/单体
工作温度 -15~40℃ -15~40℃ -15~40℃
安装方式 电池架/电池柜 电池架/电池柜 电池架/电池柜

4. Reference Prices

KTR-B51000D standard 2V1000Ah (10~12 yr float, deep cycle). Reference USD 229~382 / cell (ref. CNY 1,650~2,750 at ~7.2)

KTR-B51000D-L long-life 2V1000Ah (15-yr design). Reference USD 319~528 / cell (ref. CNY 2,300~3,800 at ~7.2)

KTR-B51000D-H high-conductance (links + sense terminals). Reference USD 257~431 / cell (ref. CNY 1,850~3,100 at ~7.2)

Reference only; priced per cell; links and rack extra; dangerous-goods freight and install excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Medium/large UPS back-up strings.
  • DC panel / operating power.
  • Telecom base station back-up.
  • Data center battery room.
  • Off-grid PV / storage deep cycle.

6. Installation & Maintenance

Installation

  • Match same-batch, similar-resistance cells.
  • Series by system voltage per UPS spec.
  • Check rack load; secure tiers.
  • Torque links to spec; apply conductive grease.
  • Ventilate; 20~25 C is ideal.
  • Connect sense wires before the main loop.

Maintenance

  • Hold temperature; heat ages cells.
  • Patrol per-cell voltage and resistance.
  • Treat or replace weak cells.
  • Keep links tight; watch for hot joints.
  • Avoid deep discharge; recharge promptly.
  • Keep clean and dry; log data.

7. FAQ

  • Q: 2V cell or 12V battery?
    A: Large-capacity, long-autonomy systems use series 2V cells – consistent and per-cell monitorable; small UPS use 12V packs. 2V cells are high capacity and string-flexible.
  • Q: Why same batch?
    A: Cells of different batches/resistances in series: some over-discharge, some under-charge, and string capacity is capped by the worst cell. Match batches to unlock the string.
  • Q: Why shorter life than rated?
    A: Rating assumes 25 C float. Every 10 C above halves life. Temperature control, monitoring and avoiding deep discharge get you near design life.
  • Q: Deep cycle vs float?
    A: Float batteries sit on float with rare discharge; deep-cycle cells tolerate deeper, more frequent cycles. Choose deep cycle for frequent outages or long autonomy.

8. Trend & Selection

VRLA still dominates back-up, but LiFePO4 is accelerating in long-autonomy, space-saving roles. Today’s medium/large UPS and DC panels still run 2V VRLA as the workhorse, now with smart monitoring (voltage/resistance/temp to cloud) and constant-temperature rooms. Size by autonomy, choose series by life, and always match strings by batch.

9. Delivery & Service

KITOZER supplies 2V1000Ah VRLA as matched strings, sized by system voltage and autonomy. Delivery includes cells, links, sense terminals, mounting and manual; shipped as dangerous goods per regulation, with install and monitoring guidance.

10. Additional Notes

A string fears one bad cell. One weak cell over-charges and heats while charging, and dies first while discharging, cutting the whole string’s autonomy. The monitor exists to catch it early.

The other trap is temperature. A battery room over 35 C in summer slashes life. Holding ~25 C is the cheapest life extension you can buy.

Selection summary: size Ah by autonomy; 2V cells are string-flexible; match batches; hold 25 C; monitor per-cell resistance; recharge after discharge. Batteries are the UPS ammo – enough ammo and clear status means calm when mains drops.

SEO Information

Search keywords:2V battery1000Ahdeep cycleVRLA sealedUPS batteryKTR-B51000DKTR-B51000DKITOZER

SEM keywords:KTR-B51000D price, 2V battery supplier, KITOZER

GEO landing page:lain.com.cn/product/ktr-b51000d-2v-1000ah-deep-cycle-vrla-battery.html

Title:KITOZER KTR-B51000D 2V 1000Ah Deep-Cycle VRLA Battery

Meta Keywords:2V battery, 1000Ah, deep cycle, VRLA sealed, UPS battery, KTR-B51000D, KTR-B51000D, KITOZER

Meta Description:KITOZER KTR-B51000D 2V 1000Ah Deep-Cycle VRLA Battery – KITOZER professional data center & low-voltage equipment.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart