KITOZER
KITOZER

KITOZER 3 phase 380V SPD box

KITOZER KTR-3PSPD Three-Phase 380V Surge Protection Box for Data Center

Brand: KITOZER Series: KTR-3PSPD Category: Power Distribution / Surge Protection

3-phase 380V40~100kAremote alarm4+0 wiringKTR-3PSPD

KITOZER KTR-3PSPD Three-Phase 380V Surge Protection Box for Data Center

1. Overview

Room power comes from an outdoor HV transformer; during thunderstorms surges ride the line into the room, reaching thousands of volts and punching through UPS, server PSUs and switches. A surge protective device (SPD) sits between lines and PE: high-impedance normally, instant low-impedance on a surge to divert current to earth and clamp voltage to ≤2.5 kV. A 380 V three-phase room needs a three-phase SPD box with B+C two-stage protection.

The KITOZER KTR-3PSPD uses 35 mm DIN-rail modules (or wall-mount box), wired 3+1 or 4+0 (TN-S uses 4+0, one SPD across L1/L2/L3/N). Ratings: Iimp (10/350 µs) 15~25 kA, In (8/20 µs) 40 kA, Imax 100 kA, Up ≤1.8 kV. Each module has a green/red failure window and optional dry-contact remote alarm to the environment host. The box includes a main switch and (on some models) a surge counter.

Selection: class — B at the transformer LV side (10/350 µs, Iimp ≥15 kA), C at the room distribution (8/20 µs, In ≥20 kA), with ≥10 m between stages or a decoupler; wiring — TT uses 3+1, TN-S uses 4+0, and the N-PE module is mandatory; and current capacity — general rooms pick C In 40 kA/Imax 100 kA, high-lightning regions (south/east coastal) pick In 60 kA. SPDs are consumables; swap the module, not the box.

2. Key Features

Current capacity

  • In 40 kA (8/20 µs)
  • Imax 100 kA
  • Iimp 15 kA (10/350 µs)
  • Up ≤1.8 kV

Wiring

  • 3-phase 380 V 4+0
  • 35 mm DIN modules
  • Wall-mount box option
  • Failure window

Alarm

  • Dry-contact remote
  • Failure remote alarm
  • Surge counter (opt.)
  • Overcurrent disconnector

3. Specifications

Item KTR-3PSPD-S1 KTR-3PSPD-S2 KTR-3PSPD-S3
型号 KTR-3PSPD-C40 KTR-3PSPD-C60 KTR-3PSPD-B100
防护等级 C级 C级(加强) B级(一级)
In(8/20μs) 40kA 60kA 100kA
Imax 100kA 120kA 150kA
Iimp(10/350) — — 25kA
电压保护Up ≤1.8kV ≤1.8kV ≤2.0kV
接线 4+0 4+0 3+1
遥信 标配 标配 标配+计数

4. Reference Prices

KTR-3PSPD-C40 3-phase C-class (In 40 kA, 4+0): Reference USD 94~153 / pc (ref. CNY 680~1100 at ~7.2)

KTR-3PSPD-C60 3-phase C-class reinforced (In 60 kA): Reference USD 136~222 / pc (ref. CNY 980~1600 at ~7.2)

KTR-3PSPD-B100 3-phase B-class (Iimp 25 kA): Reference USD 250~389 / pc (ref. CNY 1800~2800 at ~7.2)

Spare SPD module (single pole, 20~40 kA): Reference USD 11~21 / pc (ref. CNY 80~150 at ~7.2)

Reference only; priced by class and current capacity. 1-year warranty. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room distribution C-class SPD.
  • Transformer LV side B-class SPD.
  • UPS input surge protection.
  • Outdoor equipment distribution.
  • Surveillance/fire system power SPD.

6. Deployment & Implementation

Installation

  • Parallel across L/N and PE
  • Leads ≤0.5 m
  • B/C spacing ≥10 m or decoupler
  • Ground resistance ≤4 Ω

Operations

  • Check failure window quarterly
  • Wire remote alarm to environment host
  • Inspect modules after a strike
  • Replace whole set every 3~5 years

7. FAQ

  • Q: B vs C class?
    A: B (stage 1) at the transformer LV side diverts large energy (10/350 µs, Iimp ≥15 kA); C (stage 2) at the room distribution clamps residual surges (8/20 µs, In ≥20 kA). Two stages work together; one alone is not enough.
  • Q: How do I know a module failed?
    A: Window turns red; the dry contact triggers and the environment host alarms. Once failed, the SPD no longer protects — replace the spare module promptly.
  • Q: Ground resistance?
    A: Combined room ground ≤1 Ω for critical rooms, ≤4 Ω for general. SPD ground leads should be as short as possible, ≤0.5 m — longer leads add inductance and raise clamping voltage.
  • Q: SPD lifespan?
    A: Normal life 5~10 years, but every strike consumes capacity. In high-lightning areas, check every 2~3 years and replace when the window turns red. Do not wait for failure.

8. Trend & Selection

SPDs are moving from pure protection to protection plus monitoring — smart SPDs with leakage current, surge count and temperature upload to the environment platform for life prediction. High-current (≥100 kA) modular SPDs grow with PV and wind grid ties. Integrated boxes (SPD + isolation transformer + surge counter) spread in small rooms.

9. Delivery & Service

KITOZER supplies KTR-3PSPD by class (B/C), current capacity (40/60/100 kA), wiring (3+1/4+0) and alarm (dry contact/counter). Ships with box, SPD modules, DIN rail and manual. Factory test report included. 1-year warranty; batch projects can add ground bars, arresters and decouplers.

10. Additional Notes

The #1 mistake is C-class only, no B-class. The room distribution has a C SPD but the transformer LV side lacks B, so large energy hits the undersized C stage, destroying it in one strike and taking downstream gear with it. B+C together are complete.

The second pitfall is SPD leads over 1 m. Lead inductance lifts clamping from 1.8 kV to over 3 kV and equipment still gets hit. Keep leads ≤0.5 m, straight, no loops.

The third blunder is not swapping failed modules. A red window unnoticed means the SPD is open-circuit and surges pass straight through. Wire the remote dry contact to the environment host for automatic alarm.

Selection summary: B at the transformer, C at the room, leads ≤0.5 m, ground ≤4 Ω, remote alarm to host. The SPD box is the power system’s lightning arrestor — it idles daily but saves the day in a storm.

SEO Information

Search keywords:KTR-3PSPDKITOZERThree-Phase 380V Surge Protection Box for Data Center

SEM keywords:three phase SPD box,380V surge protector,power lightning protection,data center SPD,KTR-3PSPD,KITOZER

GEO landing page:lain.com.cn/product/ktr-3pspd-3ph_spd_box.html

Title:KITOZER KTR-3PSPD Three-Phase 380V Surge Protection Box for Data Center

Meta Keywords:three phase SPD box,380V surge protector,power lightning protection,data center SPD,KTR-3PSPD,KITOZER

Meta Description:KITOZER KTR-3PSPD three-phase 380V surge protection box, 40~100 kA, dry-contact remote alarm, 4+0 wiring for room distribution.

Anchor: KITOZER by Guangzhou Laian · Three-Phase 380V Surge Protection Box for Data Center

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart