ToggleProduct Overview
The KITOZER 30kW air-cooled in-row air conditioner is a rack-height cooling unit designed to sit directly between server racks in hot-aisle or cold-aisle containment. By placing cooling close to the heat source, the in-row unit eliminates long duct runs and hot-spot formation that often plague traditional room-level precision air conditioners in high-density halls. The cabinet matches a standard 19 inch rack footprint, drawing warm exhaust air from the hot aisle and discharging cool air into the cold aisle. A single inverter compressor, EC plug fan, electronic expansion valve, and humidifier deliver tight control at partial load.
Technical Specifications
Nominal cooling capacity is 30kW sensible at 27 degrees Celsius entering air and 50 percent relative humidity. The unit runs on three phase 400V 50Hz with a maximum power draw of 11kW. Supply airflow is 7000 cubic meters per hour against 70 Pa external static pressure. Refrigerant R410A is piped to an outdoor V-type air-cooled condenser up to 30 meters away. Humidification is 4kg per hour steam. Dimensions are 600mm wide by 1200mm deep by 2000mm high, matching a standard rack bay. Weight is 320kg. Noise is 66 dBA at 3 meters. The controller supports Modbus TCP, BACnet IP, and SNMP.
Application Scenarios
This 30kW in-row unit is ideal for high-density server racks of 8 to 15kW per rack, AI training clusters, GPU compute nodes, storage area networks, and high-frequency trading cages. It is equally at home in edge computing facilities, 5G core node rooms, and retrofit projects where raised floors are absent. Hot-aisle containment paired with in-row cooling is the dominant architecture for modern data centers targeting PUE below 1.3.
Advantages and Features
Proximity to IT equipment eliminates hot-aisle recirculation and cold-aisle bypass, raising cooling efficiency. The inverter compressor modulates from 20 to 100 percent capacity, avoiding the on-off cycling that wastes energy in fixed-speed units. EC fans communicate over 0 to 10V control and can be tied to rack inlet temperature sensors. The controller supports group sequencing across multiple in-row units, with automatic duty rotation and alarm escalation. Front-to-front airflow orientation simplifies aisle containment installation. The cabinet is painted with scratch-resistant powder coat and uses tool-less filter access.
Installation and Maintenance Recommendations
The unit bolts directly to the floor or rack rail using standard mounting hardware. Refrigerant lines should be sized to minimize pressure drop, with isolation valves at the outdoor condenser. Power and communication cables route through the bottom cable tray. Filters are G4 and should be inspected every 90 days. The condenser coil should be washed annually in dusty environments. Compressor and fan vibration should be checked annually. Keep spare filters, fuses, and a humidifier cylinder on site to minimize mean time to repair.
Price
From $9,980 per unit including outdoor condenser. Contact plus 86 13922289957 for in-row AC quotation and containment layout.