Table of Contents
ToggleProduct Overview
The KITOZER 30kW DC fast charger is a compact wall or pedestal mounted direct current charging terminal designed for electric light commercial vehicles, delivery vans, taxi fleets, and company car parks. With an output voltage range of 200 to 750 Vdc and a maximum output current of 50 A, the unit delivers a stable DC feed to any vehicle that conforms to CCS2, CHAdeMO, or GB/T protocols. The converter stage uses an active front end with power factor correction to keep harmonic distortion low, and the whole enclosure is rated IP54 so it can be installed outdoors under a simple canopy without a dedicated kiosk. A 7 inch touch screen on the front door shows real time charging current, voltage, session energy, and any active fault, while an integrated RFID reader and Ethernet port make the terminal ready for OCPP 1.6J back office integration from day one. The cabinet is finished in scratch resistant powder coating and includes a stainless steel gun holster, a 4 meter cable, and an emergency stop button that is clearly labeled and easy to reach.
Technical Specifications
Input: three phase 380 V plus or minus 15 percent, 50 or 60 Hz, maximum input current 52 A. Output: 200 to 750 Vdc adjustable, 30 kW continuous, 50 A maximum. Efficiency up to 94 percent at nominal load, power factor greater than 0.99, total current harmonic distortion less than 3 percent. Connectors: one CCS2 gun and one CHAdeMO gun on a shared 30 kW pool, switchable by the controller. Cooling: forced air with temperature derating above 45 degrees Celsius. Protection: over voltage, under voltage, over current, short circuit, earth leakage, over temperature, and DC residual current detection. Display: 7 inch color touch screen. Communication: Ethernet, RS485, optional 4G module, OCPP 1.6J. Enclosure: IP54, cold rolled steel with powder coating, 35 kg, wall or pedestal mount. Operating temperature minus 30 to plus 50 degrees Celsius. Storage temperature minus 40 to plus 70 degrees. Humidity 5 to 95 percent non condensing. Noise level below 65 dB(A). Standards: CE, IEC 61851-23, IEC 61851-24, KITOZER 5 year warranty.
Application Scenarios
The 30 kW class is the sweet spot for workplace charging where vehicles park for four to eight hours but the operator still wants a meaningful top up during a lunch break. Typical deployments include municipal depot charging for small refuse and patrol vans, distribution centers for last mile delivery fleets, hotel and shopping mall visitor parking, and small dealership service bays. Because the footprint is only 350 by 220 by 600 mm, the unit fits in tight wall spaces that cannot accept a 60 kW cabinet. The dual gun option lets two vehicles share a single feeder circuit, reducing civil works and supply upgrade cost when site power is limited. It is also used at small bus depots for minibuses, at farm cooperatives for electric utility vehicles, and at public parking garages that want to offer a low cost fast charging option alongside slower AC points.
Advantages and Features
Compared with imported 30 kW terminals, the KITOZER charger keeps the same IEC and CE compliance level while cutting installed cost by nearly half. The power module is field swappable in under ten minutes, which means a site technician does not need to remove the whole cabinet when a module alarms. MID certified energy metering is built in so the charger can be used for public paid operation without an external meter. Dynamic load management lets up to sixteen chargers share one site transformer, automatically throttling output when the site total approaches the contract demand. The front end PFC stage draws a near sinusoidal current, which protects the site transformer from overheating and avoids penalty from the utility for poor power factor. The touch screen UI supports English, German, French, Spanish, Arabic, and Russian, and the firmware can be customized with the operator brand and pricing tariff.
Installation and Maintenance
Mount the unit on a reinforced concrete plinth or a solid masonry wall at eye level. Run a five core cable from the distribution board, size the breaker at 63 A type C, and verify earth resistance is below 4 ohms before energizing. The DC residual current protector must be tested annually with a calibrated RCD tester. Clean the air filters every six months in dusty environments and inspect the connectors for pin discoloration or loose pins. Firmware updates are delivered over the air via the OCPP back office, so field visits are only needed for hardware work. Keep the emergency stop button accessible and label it clearly. Recommended spares include one 30 kW power module, one display board, and one set of contactors.
Reliability and Quality
Every charger undergoes a 48 hour burn in test at full load before shipment. The power modules are sourced from tier one suppliers and screened for temperature rise under continuous operation. The enclosure passes salt spray testing for coastal installations and vibration testing for mobile sites. The KITOZER quality team tracks field fault rates by serial number and provides a root cause analysis report within seven days of a returned unit. Remote diagnostic logs are stored in the cloud portal for at least twelve months, which helps operators correlate charging sessions with fault events.
Why Choose KITOZER
KITOZER has specialized in power electronics and energy infrastructure for over a decade, exporting to more than 60 countries across Europe, the Middle East, Southeast Asia, Africa, and Latin America. The product is designed and manufactured in a modern ISO 9001 certified facility, where every unit passes a 24 to 72 hour burn in test before packaging. The engineering team works directly with project developers, electrical contractors, and EPC firms to customize voltage, communication protocol, and enclosure rating to match local grid codes and site conditions. Competitive factory direct pricing reduces total project cost by 20 to 40 percent compared with equivalent imported brands, without compromising on safety certifications or warranty coverage. The KITOZER cloud platform provides lifetime free monitoring for the standard version, so operators can track performance and receive alarms from any browser or mobile device. For large projects, the application engineering team supports site design, cable sizing, protection coordination, and grid code filing, helping the customer move from concept to commissioning with a single point of contact.
Packaging Shipping and Support
The KITOZER 30kW DC fast charger is packed in a heavy duty plywood crate with foam cushioning and desiccant bags for long sea transit. The crate is labeled with handling symbols, weight, and orientation marks, and it meets ISPM 15 requirements for international shipping. Standard lead time is 15 to 45 days depending on configuration, and rush production is available for urgent projects. Spare parts are held at regional warehouses in Europe, the Middle East, and Southeast Asia, ensuring four to eight hour response time for critical failures. The KITOZER support team provides remote commissioning guidance over video call, and on site commissioning can be arranged for turnkey projects. Every unit ships with a printed quick start guide, a USB stick containing the full user manual in English, and a factory test report. Extended warranty up to 10 years is available on request for mission critical installations.
Price
From $2,680 per unit. Contact plus 86 13922289957 for volume pricing, gun option selection, and factory lead time. Lead time is typically 15 days for stock units and 30 days for custom configurations.