KITOZER Glycol Low Temperature Air Conditioner: 30kW Minus 30C

Product Overview

The KITOZER 30 kW glycol low-temperature air conditioner is engineered for indoor equipment rooms located in cold climates where outdoor condensers must operate reliably down to minus 30 degrees Celsius. A glycol-water solution circulates between the indoor unit and an outdoor dry cooler, absorbing heat and rejecting it to ambient air without relying on an on-site chiller. The indoor unit contains the refrigeration compressor, evaporator coil, EC supply fans, and humidifier, while the outdoor dry cooler uses EC axial fans and a glycol pump skid. This configuration prevents refrigerant migration and oil return problems that plague standard air-cooled condensers in extreme cold.

Technical Specifications

Rated cooling capacity is 30 kW sensible at 23 degrees Celsius indoor and 35 degree Celsius outdoor dry cooler ambient. The glycol loop uses 35 percent ethylene glycol solution, rated to minus 35 degrees Celsius freeze protection. Glycol flow is 6 liters per second. Indoor power supply is three phase 400 V 50 Hz with 11 kW full load. Outdoor dry cooler fans draw 2.2 kW. Supply airflow is 7500 cubic meters per hour against 150 Pa. Humidification output is 5 kg per hour. Dimensions are 1800 mm wide by 900 mm deep by 2000 mm high indoors. The outdoor dry cooler is V-type with EC fans. Operating ambient range is minus 30 to 45 degrees Celsius.

Application Scenarios

Typical installations include data centers in northern China, Mongolia, Russia, Scandinavia, Canada, and northern United States. The system is used for telecom base station shelters, outdoor battery energy storage containers, ice-rink support rooms, and high-altitude research stations where ambient temperatures regularly drop below minus 20 degrees Celsius. It is also used for railway signaling equipment rooms and remote wind farm control cabins.

Advantages and Features

Glycol loop design eliminates long refrigerant lines, reducing refrigerant charge by up to 70 percent versus direct air-cooled systems. In cold seasons the dry cooler alone can absorb the entire IT load through free cooling, turning off the compressor completely and saving energy. The controller stages glycol pump speed and fan speed based on return glycol temperature. Electric trace heating protects piping in unheated corridors. Crankcase heaters and refrigerant cycle protection ensure reliable startup after long cold spells.

Installation and Maintenance Recommendations

Pipework must be insulated with closed-cell foam rated for low temperatures. Glycol concentration must be tested annually and adjusted for the design freeze point. The dry cooler coil should be flushed and treated with corrosion inhibitor every two years. Filters are inspected quarterly. The glycol pump pressure and expansion tank pre-charge are verified annually. Keep spare glycol concentrate and a pump mechanical seal on site. Commissioning should include a freeze-point test and a free-cooling mode test at low ambient temperature.

Energy and Environmental Performance

Because the dry cooler can run the compressor off for much of the winter, energy use in cold climates can be 50 percent lower than a conventional air-cooled precision unit. The glycol loop uses no ozone-depleting refrigerant in the outdoor circuit. The EC fans on the dry cooler modulate speed based on return glycol temperature, further saving energy. The unit qualifies for cold-climate green-building incentives.

Configuration Options and Warranty

The system is offered in multiple cooling capacities and with different glycol concentrations to match local winter minima. Optional extras include a glycol pump redundant standby, a 4G remote monitoring gateway, and a heated indoor sump for freeze protection. The standard warranty covers the compressor for 3 years and the dry cooler for 2 years, with extended coverage up to 5 years available. A preventive maintenance package with annual glycol analysis is recommended.

Price

From $18,500 per system including indoor unit, outdoor dry cooler, pump skid, and glycol charge. Contact plus 86 13922289957 for cold-climate precision AC quotation.