KITOZER
KITOZER

KITOZER 3150kVA High Capacity Cast Resin Dry Type Transformer

Product Overview

The KITOZER 3150 kVA cast resin dry type transformer is a heavy duty indoor unit engineered for large industrial substations, mining plant substations, data center bulk transformation, and shipyard heavy load workshops. The 3150 kVA rating steps 10 kV medium voltage down to 0.4 kV and delivers over 4500 A on the secondary busbar, enough to power a full manufacturing line or a large data center row. Copper winding is standard on this rating to keep conduction loss low and withstand repetitive inrush from large motor starts. Vacuum cast epoxy, F class insulation, and forced air cooling as standard allow cyclic overload operation in demanding environments.

Technical Specifications

Rated 3150 kVA, HV 10 kV plus or minus 2 times 2.5 percent, LV 0.4 kV, Dyn11, impedance 6.0 percent. No load loss 2.7 kW, load loss at 120 degrees 21.5 kW, no load current 0.4 percent. Insulation class F, temperature rise 100 K. Cooling AN with AF fans standard, AF output 1.4 times rated. Partial discharge below 10 pC. Enclosure IP20 standard, IP31 optional. Secondary copper busbar rated 5000 A, HV cable box with dual cable entries. Temperature controller with multi channel PT100, event log, Modbus RTU, alarm and trip relays. Core is step lap grain oriented steel with tied down frame. Noise below 68 dB with anti vibration pads. Weight approximately 6500 kg. CE, IEC 60076, GB/T 1094.11.

Application Scenarios

The 3150 kVA rating serves large automotive press shops, steel rolling mills, mining hoist substations, pulp and paper machine rooms, large data center bulk transformers, and port container crane power. Because it is dry and flame retardant, it is placed in indoor substation rooms adjacent to production. The AF cooling supports cyclic load such as crane duty or press cycle where short peak currents exceed rating. IP31 enclosure is used in dusty cement, mining, or wood processing plants. Parallel operation of two or three units provides redundancy for continuous process industries such as glass, chemical, and semiconductor fabs.

Advantages

Copper winding gives low resistance and high short time overload capacity. Forced air fans as standard avoid derating during peak load. The multi channel temperature controller provides winding, core, and ambient monitoring with event history for root cause analysis. Modbus RTU connects directly to SCADA or energy management systems. The unit is designed for short circuit level up to 50 kA for 1 second on the LV side, matched with downstream main breakers. Standardized busbar arrangement allows easy parallel operation with identical KITOZER units. Five year warranty covers winding, core, and cooling fan assembly.

Installation and Maintenance

Install on a reinforced concrete plinth engineered for over 7000 kg dynamic weight. Maintain 1.8 m front clearance for busbar access and 1.2 m sides for cooling air. Use shielded 12 kV cables rated for short circuit and terminate with heat shrink kits. Connect LV via flexible laminated busbar to absorb thermal expansion. Commissioning includes tap selection, phase rotation check, insulation measurement at 5000 V, and short circuit impedance test. After one month of operation, re torque all busbar bolts. Annual maintenance: clean core with dry compressed air, test fan bearings, calibrate PT100, check Modbus communication. Every five years: partial discharge test, dissipation factor measurement, and enclosure gasket replacement. Keep substation room temperature below 40 degrees C and avoid blocked airflow.

Price

From $52,000 per piece with copper winding, IP20 enclosure, AF fans, and Modbus temperature controller. Higher impedance, IP31 enclosure, and parallel operation kits are optional.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top