KITOZER
KITOZER

KITOZER 3150kVA Dry Type Transformer 10kV for Heavy Industry

Product Overview

The KITOZER 3150kVA dry type transformer is a high capacity cast resin distribution unit designed for heavy industrial loads including arc furnaces, rolling mills, large HVAC plants, and municipal infrastructure. Stepping 10kV to 400V, the unit combines a robust silicon steel core, encapsulated copper windings, and redundant forced air cooling to deliver continuous duty with low audible noise. KITOZER builds each transformer to order, with options for parallel operation, special impedance, and harmonic mitigating winding to support severe nonlinear load profiles. The unit is engineered for 30 year service in tough industrial environments and is supplied with a full protection and monitoring package.

Technical Specifications

Rated 3150kVA, 10kV primary, 400V secondary, 50Hz. Vector group Dyn11. Impedance 6 percent or 8 percent on request. Insulation class F, 100K rise. Cooling AN with AF fans providing 140 percent rating. Off circuit tap changer plus or minus 2 by 2.5 percent. Partial discharge less than 10pC. Sound level below 68dB. Protection enclosure IP20 standard, IP23 optional. Temperature controller with PT100, four stage alarm, fan control, trip contact. Routine tests: induced voltage 72kV for 60 seconds, applied voltage 28kV for 60 seconds, impulse 75kVpeak. Weight approximately 12500kg, dimensions 3100mm by 1900mm by 3100mm. Standards IEC 60076, GB/T 1094, CE. The LV busbar is sized for 5000A continuous current.

Application Scenarios

This unit is used in steel processing plants, aluminum smelters, large water treatment pumping stations, stadiums, convention centers, and hospital central plants. It supplies main LV switchboards feeding large motor control centers, VFD driven pumps, and UPS backed critical systems. The dry type construction is accepted in indoor substations and urban power distribution where oil is restricted. In large industrial complexes, two or more 3150kVA units are paralleled on a common LV bus to support growing production load.

Advantages and Features

High short circuit withstand capacity protects through system faults. Redundant cooling fans ensure continued operation after a single fan failure. The heavy duty frame and bracing withstand electrodynamic forces during through faults. KITOZER offers a harmonic mitigating winding to reduce 5th and 7th harmonic currents from VFDs. Optional stainless steel enclosure suits coastal or chemical environments. Factory witness testing and on site commissioning support are available. The unit is designed for parallel operation with identical units on a common LV busbar.

Installation and Maintenance

Requires a 15 ton rated concrete foundation. Use lifting beams on the four corner lifting points. Maintain 1200mm service clearance. Ensure forced ventilation supplies at least 12000 cubic meters per hour of cool air. Torque HV and LV bus bolts to specification after first year in service. Test insulation resistance annually. Clean winding surfaces with dry compressed air. KITOZER recommends thermal imaging during peak load and a five year major inspection including core earth bond check and cooling fan bearing replacement.

Construction and Quality Assurance

The 3150kVA unit uses a heavy duty welded steel frame and bracing designed to withstand through fault electrodynamic forces up to 31.5kA. The LV windings are wound with copper foil to improve short circuit strength, while the HV winding is layered for better voltage distribution. The core is built from premium grain oriented steel with step lap construction. KITOZER performs a full type test including temperature rise, short circuit withstand, and impulse test. The redundant cooling fan system includes N plus 1 fans with independent circuits. Each unit is supplied with a complete test certificate, foundation drawing, and lifting plan. The factory can provide a site commissioning engineer for large industrial projects.

Packaging and After Sales Support

The heavy duty 3150kVA unit is shipped on a custom steel skid with the enclosure fitted. KITOZER provides a lifting plan and can support on site installation and commissioning. The 5 year warranty covers core, windings, and cooling fans. Spare parts including PT100 sensors, fan motors, and temperature controllers are held in stock. For continuous process plants, KITOZER offers a long term service agreement with annual thermal imaging and insulation resistance testing to maximize uptime.

For continuous process plants, KITOZER offers a parallel ready option that includes matched impedance and load sharing wiring, so two or more units can be connected on a common LV busbar without circulating current. This is commonly used in steel mills and large water treatment plants where N plus 1 redundancy is required. The unit can also be supplied with a built in power quality meter and harmonic analyzer to monitor loading health over time.

The 5 year warranty covers manufacturing defects in core, winding, and cooling system. KITOZER also offers extended warranty options up to 10 years for critical industrial installations.

Price

From $22,800/pc. Contact +86 13922289957 for heavy duty transformer quote.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com