KITOZER 3150kVA Dry Type Transformer 10kV for Heavy Industry

Product Overview

The KITOZER 3150kVA dry type transformer is a high capacity cast resin distribution unit designed for heavy industrial loads including arc furnaces, rolling mills, large HVAC plants, and municipal infrastructure. Stepping 10kV to 400V, the unit combines a robust silicon steel core, encapsulated copper windings, and redundant forced air cooling to deliver continuous duty with low audible noise. KITOZER builds each transformer to order, with options for parallel operation, special impedance, and harmonic mitigating winding to support severe nonlinear load profiles.

Technical Specifications

Rated 3150kVA, 10kV primary, 400V secondary, 50Hz. Vector group Dyn11. Impedance 6 percent or 8 percent on request. Insulation class F, 100K rise. Cooling AN with AF fans providing 140 percent rating. Off circuit tap changer plus or minus 2 by 2.5 percent. Partial discharge less than 10pC. Sound level below 68dB. Protection enclosure IP20 standard, IP23 optional. Temperature controller with PT100, four stage alarm, fan control, trip contact. Routine tests: induced voltage 72kV for 60 seconds, applied voltage 28kV for 60 seconds, impulse 75kVpeak. Weight approximately 12500kg, dimensions 3100mm by 1900mm by 3100mm. Standards IEC 60076, GB/T 1094, CE.

Application Scenarios

This unit is used in steel processing plants, aluminum smelters, large water treatment pumping stations, stadiums, convention centers, and hospital central plants. It supplies main LV switchboards feeding large motor control centers, VFD driven pumps, and UPS backed critical systems. The dry type construction is accepted in indoor substations and urban power distribution where oil is restricted.

Advantages and Features

High short circuit withstand capacity protects through system faults. Redundant cooling fans ensure continued operation after a single fan failure. The heavy duty frame and bracing withstands electrodynamic forces during through faults. KITOZER offers a harmonic mitigating winding to reduce 5th and 7th harmonic currents from VFDs. Optional stainless steel enclosure suits coastal or chemical environments. Factory witness testing and on site commissioning support are available.

Installation and Maintenance

Requires a 15 ton rated concrete foundation. Use lifting beams on the four corner lifting points. Maintain 1200mm service clearance. Ensure forced ventilation supplies at least 12000 cubic meters per hour of cool air. Torque HV and LV busbolts to specification after first year in service. Test insulation resistance annually. Clean winding surfaces with dry compressed air. KITOZER recommends thermal imaging during peak load and a five year major inspection including core earth bond check.

Price

From $22,800/pc. Contact +86 13922289957 for heavy duty transformer quote.