KITOZER Distribution Monitor: 36 Loop Power Monitoring Unit

Product Overview

The KITOZER 36 loop distribution power monitoring unit is a multi-circuit power metering and protection device designed for low voltage switchboards, rack power distribution units, and branch circuit panels in data centers, commercial buildings, and industrial plants. The unit measures voltage, current, power, energy, and power factor on up to 36 outgoing branch circuits simultaneously, and it reports the data over RS485 Modbus RTU or Ethernet Modbus TCP to a central monitoring platform. By replacing dozens of individual panel meters with a single compact unit, the KITOZER distribution monitor simplifies wiring, reduces panel space, and gives facility managers a consolidated view of every branch circuit load.

Technical Specifications

The main input is three phase four wire 400V nominal, 50 Hz or 60 Hz. The unit supports up to 36 branch channels, each measured through a current transformer with a standard 5A secondary, selectable from 5A to 630A primary rating. Per-channel measurement includes RMS current, voltage on adjacent phase, active power, reactive power, apparent power, power factor, and accumulated energy. Sampling rate is 32 samples per cycle, with measurement accuracy class 0.5 for current and voltage and class 1 for energy. The unit provides over-current, under-current, and over-temperature alarms on each channel, with threshold settings configurable per channel through the Modbus register map. Communication ports include two isolated RS485 ports and one Ethernet port supporting Modbus TCP. The unit also provides eight Form C alarm relay outputs and eight digital inputs. Power supply is universal 85V to 265V AC or DC, drawing less than 8W. Mounting is on a 35 mm DIN rail inside the distribution panel, or on a panel door with a remote display module. Operating temperature range is minus 10 to plus 55 degrees Celsius. CE marked.

Applications

The 36 loop monitoring unit is widely used in data center main switchboards, rack-level PDU distribution, office building floor distribution panels, factory machine tool power panels, and hospital critical outlet circuits. It is also deployed in commercial building energy management systems where every branch circuit must be separately billed or allocated to a tenant. Integrators use the unit when retrofitting existing switchboards with monitoring capability because it fits into the existing panel without adding a separate meter per feeder. The unit is also suitable for UPS output distribution panels, generator output panels, and busway tap-off monitoring.

Advantages and Features

The KITOZER 36 loop monitor consolidates 36 branch measurements into one DIN-rail device, reducing panel space and wiring cost compared with installing 36 individual meters. The high sampling rate captures load transients and inrush events that slower meters would miss. Per-channel alarm thresholds allow the system to warn maintenance teams before a branch circuit becomes overloaded, which is especially valuable in data centers where rack power demand grows over time. The dual RS485 and Ethernet ports support daisy-chaining multiple units on a single serial bus and simultaneous polling by a local SCADA and a remote DCIM platform. The remote display option allows the main unit to be installed inside the panel while the display sits on the door for local reading. The unit is firmware upgradable through the Modbus port, and KITOZER provides a free configuration tool for Windows that reads and writes all parameters. The device also supports demand management by recording the maximum demand on each branch over a configurable window, which helps facilities identify circuits that are approaching their rated capacity before they trip. Because the measurement is synchronized across all 36 channels, the reported total power matches the sum of branch powers within measurement error, which is important for energy accounting and tenant sub-billing. The unit also supports a built-in web HMI when the Ethernet option is fitted, so an operator can view live branch loads from a browser without logging into a separate head-end software. A free PC configuration tool allows the installer to read all 36 channels, set thresholds, and save configuration templates that can be copied to similar panels on other floors.

Installation and Maintenance Recommendations

DIN-rail mount the main unit inside the distribution panel, and install current transformers around each branch conductor. Use CTs with a 5A secondary and match the primary rating to the expected branch load. Keep the CT secondary wiring short and away from power conductors to minimize noise. Set the Modbus address, baud rate, and communication parameters before connecting to the upstream network. During commissioning, verify each channel reading against a calibrated clamp meter and confirm that per-channel alarms trigger correctly when thresholds are exceeded. The unit requires no scheduled maintenance, but the ventilation slots should be cleaned during routine panel inspection visits. Firmware updates are optional and only recommended when a new feature is required. KITOZER provides a three year warranty and technical support through the regional office.

Price

From $680 per piece including the main unit, CTs sold separately. Contact KITOZER for CT pricing, communication option pricing, and factory lead time.