The KITOZER 4-zone gas extinguishing control panel supervises up to four independent detection and release zones, making it suitable for larger installations with multiple protected rooms or multi-hazard pipe network systems. Each zone can have its own detection loop, pre-discharge alarm, abort station, and release circuit, all coordinated from one cabinet. The panel integrates with the building fire alarm system and provides remote status via relay outputs or optional Modbus.
Table of Contents
ToggleProduct Overview
The panel is housed in a steel enclosure with a front door containing an LCD, zone indicator LEDs, and push buttons. Inside, the main controller supervises four Class B detection loops, four release circuits, and programmable relay outputs. A built-in battery charger maintains sealed lead-acid batteries for standby operation. The panel supports cross-zone logic within each zone and interlocking between zones for selector valve systems.
Technical Specifications
Four supervised detection zones, Class B. Four release circuits at 24 volts DC, 1.5 amperes each. Pre-discharge alarm 0 to 60 seconds programmable. Abort timer programmable. Power input 100 to 240 volts AC. Battery backup 24 volts DC, 24 hours standby plus 5 minutes alarm. Relay outputs are six Form C at 2 amps. Optional Modbus or Ethernet. Operating temperature 0 to 40 degrees Celsius. Enclosure IP30 steel.
Application Scenarios
The 4-zone panel protects data centers with multiple server rooms, industrial plants with several switchgear enclosures, commercial buildings with multiple archive or treasury rooms, and marine vessels with multiple machinery spaces. In selector valve systems, one zone controls the detection and another controls the selector valve release, allowing coordinated protection of several hazards from a central cylinder bank.
Advantages
Four zones in one panel reduce cost versus multiple 2-zone panels. Independent release circuits allow different zones to discharge on their own logic. Cross-zone confirmation minimizes false release. Relay outputs integrate with building management. Battery backup ensures operation during power failure. The LCD provides clear per-zone diagnostics. Modbus option enables remote monitoring.
Installation and Maintenance
Mount the panel in the fire control room or near the cylinder bank. Route detection and release wiring in separate conduit. Commission each zone individually with a walk test. Test release logic with a dummy load. Inspect batteries annually and replace every 3 to 5 years. Test all functions quarterly. Keep firmware updated via the service port. Label each zone clearly on the fascia.
Engineering Notes
Mount the panel in the fire control room. Label each zone clearly on the fascia. Route detection and release wiring in separate conduit. Provide battery backup for 24 hours. Test all zones quarterly. Keep spare relay cards on site.
Code and Compliance
The panel must comply with local fire alarm and gas release standards. Submit the zone schedule and release logic for approval. Annual testing includes each zone. Keep a service log on site. Replace batteries every 3 to 5 years.
Warranty and Accessories
From $1,480 per 4-zone panel, excluding battery and detectors. The panel carries a two-year warranty. KITOZER supports zone design and networking. Spare batteries, relay cards, and display boards are held in stock. Contact +86 13922289957 for larger panels and networking options.
Detailed Application Examples
A 4-zone panel protects four server rooms in a data center. Each zone has its own detection loop and release circuit, and interlocks prevent simultaneous discharge. The LCD shows per-zone status, and Modbus reports to DCIM. Batteries are replaced every 4 years, and all zones are tested quarterly.
Long-term Operational Benefits
The 4-zone panel consolidates four release circuits in one cabinet, reducing wall space and wiring cost. Because each zone is independent, a fault in one does not disable the others. The LCD gives clear per-zone diagnostics without a laptop. Modbus integration allows remote monitoring. A two-year warranty covers the panel electronics.
System Integration
The 4-zone panel integrates with the building fire alarm system through relay contacts and optional Modbus. Each zone can be programmed independently, with its own pre-discharge delay and release logic. Interlocking between zones prevents simultaneous discharge. The LCD shows per-zone status, and the event log records every alarm, abort, and release. This makes the panel suitable for multi-zone data centers and industrial plants.
Price
From $1,480 per 4-zone panel, excluding battery and detectors. Contact +86 13922289957 for larger panels and networking options.