The KITOZER 400A automatic transfer switch (ATS) cabinet ensures seamless switching between utility mains and backup generator power for critical three-phase loads. Rated at 400A, 400V, the unit uses a heavy-duty mechanically interlocked contactor to prevent simultaneous connection of both sources. When utility voltage drops outside the programmable window, the ATS starts the generator, waits for stable voltage, then transfers the load. When utility returns, it re-transfers after an adjustable delay and stops the generator after cool-down. The cabinet is wall or floor mounted and suitable for commercial, industrial, and data center applications.

Product Overview

The ATS cabinet is a powder-coated steel enclosure rated IP32, housing the main changeover contactor, ATS controller, terminal blocks, and surge protection. The front panel has an LCD display showing source voltage, load current, and switch position. Push buttons allow manual operation and test mode. The controller provides programmable voltage windows, time delays, and event logging. A mechanical interlock prevents both sources from closing at once. Optional communication module provides Modbus RS485 for remote monitoring.

Technical Specifications

Rated current is 400A. Rated voltage is 400V three phase, 50 Hz. Rated short-time withstand is 30 kA for 1 second. Transfer time from generator to load is approximately 100 milliseconds. Utility sensing window is programmable, typically 180V to 260V per phase. Time delay on generator start is 0 to 60 seconds adjustable. Re-transfer delay is 0 to 300 seconds adjustable. Cool-down run-on time is 0 to 30 minutes. Mechanical interlock ensures break-before-make. Control supply is 230V. Dimensions are 800 mm wide, 1800 mm high, 500 mm deep. Weight is approximately 180 kg. Protection functions include over current, short circuit, phase loss, and phase sequence. Communication optional: RS485 Modbus. Compliance with IEC 60947-6-1.

Applications

The 400A ATS is used in small data centers, hospital labs, retail stores, office buildings, and manufacturing lines where uptime matters. It pairs naturally with a 250 to 350 kW diesel generator. In telecom base stations, it switches between grid and genset without operator intervention. In water treatment plants, it protects pumps and controls from utility interruption. The cabinet can be installed indoors or under eaves outdoors with optional weatherproof kit.

Key Advantages

Automatic transfer eliminates manual switching errors and downtime. The mechanical interlock guarantees source separation. The programmable delay prevents generator overload from large motor inrush. Event log records every transfer for compliance reporting. The compact cabinet fits in existing electrical rooms. Modbus integration ties the ATS into BMS and DCIM. The contactor is rated for millions of operations, far exceeding contactor life of older ATS designs.

Installation and Maintenance Advice

Mount the ATS downstream of both utility incomer and generator output, upstream of the main distribution panel. Verify phase rotation on both sources. Connect neutral and ground per local code. Set voltage windows and delays during commissioning. Test transfer by simulating utility failure. Inspect contactor contacts annually. Tighten power terminals every 2 years. Keep the cabinet door closed to prevent dust. Lubricate mechanical linkage every 2 years. Test emergency stop and manual override quarterly.

Price

From $3,800 per ATS cabinet, ex works. Contact us for matching generator and commissioning support.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com