Table of Contents
ToggleProduct Overview
The KITOZER 400kVA dry type transformer is a medium voltage to low voltage distribution unit engineered for industrial plants, manufacturing workshops, and commercial complexes requiring robust power conversion without oil fire risk. The vacuum cast epoxy resin windings offer excellent electrical insulation, mechanical strength, and resistance to moisture and pollution. The core uses step lap mitered silicon steel to minimize no load loss and audible noise. KITOZER supplies the transformer as a core coil assembly with IP00 protection or fully enclosed in a sheet steel IP23 cabinet with filtered ventilation, making it suitable for dusty factory environments and indoor substation rooms. The unit is designed for 24/7 continuous operation and can withstand the frequent load cycles typical of production plants, HVAC systems, and compressed air stations.
Technical Specifications
Rated capacity is 400kVA at 50Hz, primary voltage 10kV with plus or minus 2 by 2.5 percent off circuit taps, secondary voltage 400V. Vector group Dyn11, impedance voltage 6 percent, insulation class F with 100K rise. Cooling is AN standard with optional AF forced air fans enabling 140 percent load during peak periods. Protection enclosure IP23 as standard, optional IP00, IP21, IP31. Temperature control unit supports PT100 sensors, three stage alarm, fan auto start, and dry contact trip output. Sound level is below 58dB at one meter. Routine tests include induced over voltage withstand, applied voltage, partial discharge below 10pC, no load and load loss measurement. Weight is approximately 1950kg, dimensions 1600mm by 1000mm by 1650mm. Standards: IEC 60076, GB/T 1094, GB/T 6451, CE. The HV and LV bushings are of epoxy resin type for dry indoor use, and the neutral bar is sized for full load neutral current.
Application Scenarios
This 400kVA unit is suited for automotive factories, food and beverage processing lines, textile mills, electronics assembly plants, convention centers, airport terminals, and underground railway stations. It feeds LV motor control centers, distribution panels, HVAC systems, and lighting loads. Because it is dry type, it can be placed inside production areas or adjacent to load centers to reduce cable loss. The IP23 enclosure protects against vertical water spray and foreign objects larger than 12.5mm, making it acceptable in light industrial environments. It is also commonly used as a standby transformer in hospitals and data centers where a second 400kVA unit provides redundancy.
Advantages and Features
The encapsulated winding prevents dust and conductive contaminants from degrading insulation life. The low loss core meets Tier 2 efficiency, reducing annual transformer loss expenses. The Dyn11 connection suppresses triplen harmonics common in rectifier and LED lighting loads. The thermal controller can be wired to the plant SCADA via RS485 Modbus to monitor winding temperature, fan status, and alarm history. KITOZER offers optional space saving low noise variant for office adjacent installations and a stainless steel enclosure for coastal or chemical environments. Each transformer is factory tested and supplied with a test report, installation drawing, and operation manual. The modular enclosure allows the IP23 shell to be removed for internal inspection without lifting the core coil.
Installation and Maintenance
Site preparation requires a reinforced concrete plinth with vibration isolation pads. Maintain 800mm front and rear clearance for HV and LV cable termination. Ensure ambient temperature remains below 40 degrees Celsius and relative humidity below 95 percent. Connect grounding busbar to plant earth grid with less than 4 ohm resistance. Inspect annually: clean ventilation filters, torque HV and LV cable lugs, verify PT100 sensors, and record winding resistance. Reapply touch up paint if enclosure coating is damaged. KITOZER recommends a thermal imaging scan during peak load season to detect hot spots on busbars and connections. In coastal installations, inspect the enclosure for salt corrosion every six months and rinse with fresh water as needed.
Construction and Quality Assurance
KITOZER windings use oxygen free copper and are vacuum cast to eliminate internal voids. The step lap core is mitered and annealed to minimize no load loss and magnetostriction noise. Each unit passes a partial discharge test below 10pC, an induced over voltage test, and a full load loss measurement at rated current. The IP23 enclosure is fabricated from 2mm sheet steel, powder coated with polyester paint, and fitted with filtered ventilation louvers. KITOZER maintains ISO 9001 certified production and provides a complete test report with every shipment. The heavy duty steel base frame includes lifting lugs and fork lift pockets for safe installation.
Packaging and After Sales Support
KITOZER packs each transformer in a seaworthy plywood case with desiccant bags and a moisture indicator. The unit is strapped to a steel skid for container loading. After installation, KITOZER provides remote commissioning support and a 5 year warranty covering manufacturing defects. Spare parts including PT100 sensors, fan motors, and temperature controllers are held in stock for rapid dispatch.
Price
From $5,680/pc. Contact +86 13922289957 for detailed quotation.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com