KITOZER 40ft Container Data Center 120kW Liquid Cooled

Product Overview

The KITOZER 40ft container data center at 120kW IT load combines a high-density liquid cooling architecture with the familiar 40ft shipping container form factor. It is designed for organizations running GPU compute, artificial intelligence training, high-performance simulation, and storage-heavy workloads that exceed the practical limits of air-cooled racks. Inside the container, up to 24 racks can be arranged in two rows, with rear-door heat exchangers on dense racks and a central service aisle. The external plant includes an air-cooled chiller and an emergency dry-cooler for redundancy, ensuring continuous cooling even if one chiller is under maintenance.

Technical Specifications

Rated IT load is 120kW continuous, supporting per-rack densities up to 15kW with rear-door liquid cooling. The CDU delivers 40 percent propylene glycol at 35 degrees Celsius supply and 45 degrees return, with a total cooling capacity of 180kW and 100 percent redundant pumps. Air conditioning provides supplementary cooling at 25kW for the service corridor and control equipment. Power distribution includes a 400A three-phase mains inlet, 160kVA online UPS with 30 minutes battery autonomy, and busway distribution to racks. The KITOZER master controller monitors liquid flow, temperature delta, pump speed, leak detection, and electrical parameters, exporting via Modbus TCP, SNMP, and REST API. Operating ambient range is minus 25 to 50 degrees Celsius, IP55 enclosure.

Application Scenarios

This 120kW liquid-cooled container is deployed for AI model training clusters, media rendering farms, seismic data processing, automotive crash simulation, and scientific research computing. It is also suitable for edge locations near 5G core nodes that need low-latency GPU inference for computer vision and natural language workloads. Financial institutions use it as a quantitative trading compute module that can be relocated near exchange points. Healthcare organizations deploy it for medical imaging analysis and genomic sequencing processing in locations where building a traditional data hall is too slow or too expensive.

Advantages and Features

Liquid cooling allows 120kW of IT load in a 40ft footprint that would otherwise require nearly twice the space with air cooling. The target PUE is below 1.20 in moderate climates, reducing both electricity cost and carbon footprint. The CDU uses redundant pumps and modular heat exchangers, so any single component can be serviced without taking the container offline. Dry-break couplings on every rack loop eliminate spill risk during server installation or removal. The KITOZER monitoring platform provides real-time thermal mapping across all racks and integrates with third-party DCIM and energy management systems. Optional features include on-site battery energy storage, solar photovoltaic input, and hydrogen fuel cell backup for resilient off-grid operation.

Installation and Maintenance Recommendations

Site preparation requires a reinforced concrete pad, a 400A three-phase power feed, and a flat area for the external chiller with adequate airflow clearance. During commissioning, flush the liquid loop thoroughly, test the glycol concentration, and pressure-test all couplings before connecting racks. Routine maintenance includes quarterly filter changes on the CDU, semi-annual chiller condenser cleaning, annual coolant quality analysis, and UPS battery impedance testing. The KITOZER controller tracks pump run hours and filter pressure differential, generating predictive work orders before performance degrades. For winter operation in cold climates, ensure that external pipework is insulated and trace-heated, and that the dry-cooler antifreeze concentration meets local climate requirements.

Reliability and Quality Assurance

The 120kW liquid-cooled container undergoes extended factory testing including 72 hours of full thermal load, pressure decay tests on every liquid loop, and insulation resistance checks on all power circuits. The CDU pumps, heat exchangers, and dry-break couplings are pressure-rated to twice operating pressure, and every leak detection cable is continuity-tested before shipment. KITOZER provides complete as-built documentation with P&ID drawings, electrical schematics, test certificates, and spare part lists. The design service life is 20 years, with redundant pumps and N+1 cooling ensuring continuous operation. A five-year warranty covers manufacturing defects, and extended service contracts include annual coolant analysis and pump performance audits. Regional spare parts stocking ensures fast replacement of filters, pumps, and couplings, while the remote support team monitors CDU performance trends 24/7.

Sustainability and Environmental Responsibility

The liquid cooling architecture reduces overall energy consumption by cutting fan power and raising chilled water temperatures, contributing to a smaller carbon footprint. The container uses recyclable steel and insulation materials, and all electronic components are selected for compliance with RoHS directives. Waste heat from the process can optionally be recovered for space heating or hot water in adjacent buildings. KITOZER also offers on-site battery energy storage and solar PV integration, enabling the container to operate with a high share of renewable energy over its lifecycle. These measures help customers meet corporate sustainability targets and reduce exposure to volatile utility prices.

Price

From $118,000 per unit, including CDU, chiller, rear-door heat exchangers, 160kVA UPS, and factory FAT. Contact KITOZER for a detailed design based on rack density and climate.