Table of Contents
ToggleProduct Overview
The KITOZER 40ft container data center rated at 500kW IT load is a megascale compute module designed for hyperscale operators and large enterprise data centers that need to add capacity in weeks rather than years. Each container functions as an independent data hall with its own power, cooling, and monitoring systems, and can be clustered with dozens of identical units to build a multi-megawatt campus. The design emphasizes liquid cooling efficiency, resilience through redundancy, and standardized factory production to achieve predictable cost and schedule. Typical deployments include cloud provider expansion zones, high-density GPU training campuses, and government supercomputing sites that require rapid, scalable, and relocatable infrastructure.
Technical Specifications
Rated IT load is 500kW continuous, supporting up to 42 racks at average 12kW density, with peak support up to 20kW per rack via direct liquid cooling. The cooling system uses a 700kW central chiller plant with free cooling, N+1 pumps, and in-row CDU units inside the container. Power distribution includes a 1250A three-phase main switchboard, 500kVA modular UPS with 20 minutes battery autonomy, and brushless busway distribution with per-rack metering. The KITOZER master controller provides a 24-inch wall-mounted HMI, 256 monitoring points, and federated site management across multiple containers. Fire suppression uses pre-engineered gas suppression with aspirating detection. Enclosure is IP55, operating range minus 30 to 50 degrees Celsius, with C5-M anti-corrosion option.
Application Scenarios
This 500kW module is intended for hyperscale cloud campuses, high-density GPU training farms, large scientific computing installations, and national data center parks. It is also used as a temporary megawatt-scale capacity buffer during planned data center expansions, and as a permanent outdoor data hall in climates where building a traditional structure is expensive or slow. Utility companies deploy clusters of these modules behind solar farms to form renewable-powered compute hubs. Research institutions use them as relocatable supercomputer shelters for climate modeling, particle physics simulation, and genomic processing.
Advantages and Features
The 500kW module achieves a target PUE below 1.15 in temperate climates through comprehensive liquid cooling and free cooling, dramatically reducing energy cost and water usage. Standardized production at the KITOZER factory allows consistent quality and short lead times, even for multi-unit orders. The modular architecture means capacity can be added one container at a time, matching business growth and avoiding over-investment in unused space. Each container is fully self-contained, so a fault in one module does not propagate to others. KITOZER provides a unified DCIM platform that aggregates power usage, temperature maps, and alarm history across the entire campus, enabling energy optimization and capacity planning.
Installation and Maintenance Recommendations
Site preparation requires a reinforced concrete slab capable of supporting up to 20 tons per container, a medium-voltage utility connection with on-site transformer, and a network fiber ring. Containers are offloaded by gantry crane and positioned with millimeter accuracy. During commissioning, the medium-voltage switchgear, UPS battery systems, and chiller plant must be tested and synchronized before IT load is introduced. Routine maintenance follows a structured program: weekly filter inspection, monthly electrical torque checks, quarterly battery testing, semi-annual chiller overhaul, and annual fire suppression certification. KITOZER offers long-term service contracts with guaranteed response times and spare parts stocking, ensuring that high-availability workloads remain protected throughout the equipment lifecycle.
Reliability and Quality Assurance
The 500kW megascale module is factory-tested for 96 hours under full megawatt-scale load, with medium-voltage switchgear, UPS systems, chiller plant, and liquid cooling loops all verified before shipment. The container shell is load-tested for extreme wind and seismic conditions, and the IP55 seal is pressure-decay tested. Critical components carry internationally recognized certifications, and the entire assembly complies with CE, IEC, and ISO standards. KITOZER provides a comprehensive documentation package including as-built drawings, P&ID schematics, test reports, and spare part lists. The design service life is 20 years, with N+1 or 2N redundancy on all critical systems. A five-year warranty covers manufacturing defects, and extended service contracts include on-site spare parts storage and guaranteed response times. The remote support team monitors the federated DCIM around the clock, enabling predictive maintenance and rapid fault resolution across large campuses.
Sustainability and Environmental Responsibility
The comprehensive liquid cooling and free cooling design achieves a target PUE below 1.15, among the most efficient in the industry, dramatically reducing energy and water use. The 40ft container is built from fully recyclable corten steel, and all electronics meet RoHS standards. Waste heat can be recovered for district heating, and the unit integrates with solar farms and battery storage for renewable-powered operation. The standardized relocatable modules can be redeployed rather than demolished, reducing construction waste. These measures help hyperscale operators meet ambitious carbon reduction targets and qualify for green grid tariffs.
Price
From $485,000 per unit, including chiller plant, 500kVA UPS, busway, liquid cooling distribution, and factory FAT. Contact KITOZER for campus-level pricing and site master planning.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com