KITOZER
KITOZER

KITOZER 40ft Container Data Center 80kW Air Cooled Standard

Product Overview

The KITOZER 40ft container data center rated at 80kW IT load is a prefabricated, transportable data hall built inside a standard high-cube 40ft shipping container. It is engineered for organizations that need to expand compute capacity quickly without constructing a traditional building. The unit houses up to 20 server racks in a hot-aisle contained configuration, with integrated power, cooling, monitoring, fire suppression, and security systems pre-tested at the factory. Typical users include internet service providers, cloud infrastructure operators, government data bureaus, and large enterprises that need modular capacity for seasonal peaks or project-specific workloads.

Technical Specifications

The container supports 80kW of continuous IT load across 20 racks at 4kW average density. Cooling is provided by four 25kW precision air conditioners in N+1 redundancy, maintaining cold aisle temperature at 24 degrees Celsius and relative humidity between 40 and 60 percent. Power distribution includes a 250A three-phase mains incomer, 100kVA online UPS with 20 minutes of battery backup, and rack-level switched PDUs with current monitoring. The KITOZER master controller visualizes all electrical, thermal, and security parameters on a 15-inch touchscreen and exports data via Modbus TCP, SNMP, and REST API. Fire suppression uses gas-based clean agent with VESDA aspirating detection. Physical security includes biometric access, door contacts, and CCTV with local NVR storage. Operating temperature range is minus 20 to 55 degrees Celsius, enclosure IP55.

Application Scenarios

This 80kW 40ft container is commonly used as a rapid expansion module for colocation providers, as a secondary disaster recovery site for enterprises, and as a temporary data hall during renovation of existing computer rooms. It is also deployed at large sporting events, music festivals, and public safety operations where event infrastructure requires on-site processing of video, sensor, and communication data. Retail chains use the unit as a regional data node for inventory and point-of-sale systems, while universities deploy it as a temporary research compute cluster during campus expansion projects.

Advantages and Features

The factory-integrated design reduces on-site installation time to one week after pad preparation, compared with six to twelve months for a traditional brick-and-mortar data hall. The hot aisle containment architecture improves cooling efficiency and delivers a target PUE below 1.40 in temperate climates. All critical systems are N+1 redundant, so a single UPS module, air conditioner, or fan failure triggers an alarm without load interruption. The container can be delivered by standard truck, loaded by container crane, and relocated as business needs change. KITOZER provides remote management through a cloud portal that aggregates alarms, energy usage, and environmental data across multiple container sites.

Installation and Maintenance Recommendations

Site preparation includes a level reinforced concrete pad with drainage, a 250A three-phase power feed, and fiber network termination. The container must be anchored against wind uplift in exposed locations. During commissioning, verify that all rack PDUs are properly phased and that the UPS battery string floats within manufacturer voltage tolerance. Routine maintenance includes monthly filter changes on air conditioners, quarterly battery impedance tests, semi-annual calibration of temperature sensors, and annual fire suppression inspection. The KITOZER controller tracks component runtime and schedules predictive maintenance, reducing unplanned downtime. For coastal installations, inspect the external paint and zinc anodes annually and touch up scratches to prevent corrosion.

Price

From $68,500 per unit, including 100kVA UPS, N+1 cooling, 20 rack positions, and factory FAT. Contact KITOZER for volume pricing and customization options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com