KITOZER
KITOZER

KITOZER 40kA Type 2 Surge Protective Device For Power Panel

Product Overview

The KITOZER 40kA type 2 surge protective device (SPD) protects low voltage switchgear, UPS systems, and sensitive electronics from lightning induced surges and switching transients. The modular plug in design allows each surge module to be replaced without de energizing the panel, and a remote contact signals the building management system when a module needs replacement. The SPD mounts on a standard 35 mm DIN rail and fits easily into new or existing distribution boards.

Technical Specifications

Rated voltage: 230 V or 400 V three phase. Nominal discharge current In: 20 kA 8 by 20 microsecond. Maximum discharge current Imax: 40 kA. Voltage protection level Up: 1.5 kV. Response time less than 25 ns. Pole configuration: 1P, 1P plus N, 3P, 3P plus N, 4P. Remote contact: dry contact, 250 V 0.5 A. Operating temperature minus 40 to plus 85 degrees. Mounting: 35 mm DIN rail. Standards CE, IEC 61643-11, KITOZER 3 year warranty.

Application Scenarios

The type 2 SPD is installed at the main low voltage distribution panel of every commercial building, data center, and factory. It is also fitted at the input of UPS systems, precision air conditioners, and server racks. In lightning prone regions, a type 1 plus type 2 combination SPD is used at the service entrance, and this type 2 unit is installed at the sub distribution panel for additional protection.

Advantages and Features

The plug in module design allows replacement without shutting down the panel, which is critical for 24/7 facilities. The visual window on each module shows green when healthy and red when degraded, so maintenance staff can spot a failed SPD at a glance. The remote contact integrates with the building management system, triggering an alarm before a surge event causes downtime. The low voltage protection level of 1.5 kV ensures connected equipment sees only a small fraction of the incoming surge.

Installation and Maintenance

Mount the SPD base on the DIN rail near the main breaker, connect the line side to the incoming supply, and the load side to the protected busbar. The earth conductor should be as short as possible, ideally under 0.5 m, to minimize lead inductance. Verify the remote contact wiring during commissioning. Inspect the visual window annually and replace any module showing red. Replace all modules after a major surge event, even if the window still shows green.

Typical System Configuration

A complete KITOZER installation typically includes the main unit, a matching distribution or protection accessory, a surge protective device, and a remote monitoring gateway. The system can be extended in phases as the load grows, which allows the customer to start with a smaller footprint and add capacity later. The engineering team provides a single line diagram, a bill of materials, and a cable schedule with every project, so the electrical contractor can install the equipment without additional design work. Remote monitoring is available via web browser or mobile app, showing real time status, alarm history, and energy consumption trends. The system supports Modbus RTU, Modbus TCP, and SNMP for integration with building management or SCADA platforms. On site commissioning, operator training, and spare parts kits are available as optional services for turnkey projects.

Why Choose KITOZER

KITOZER has specialized in power electronics and energy infrastructure for over a decade, exporting to more than 60 countries across Europe, the Middle East, Southeast Asia, Africa, and Latin America. The product is designed and manufactured in a modern ISO 9001 certified facility, where every unit passes a 24 to 72 hour burn in test before packaging. The engineering team works directly with project developers, electrical contractors, and EPC firms to customize voltage, communication protocol, and enclosure rating to match local grid codes and site conditions. Competitive factory direct pricing reduces total project cost by 20 to 40 percent compared with equivalent imported brands, without compromising on safety certifications or warranty coverage. The KITOZER cloud platform provides lifetime free monitoring for the standard version, so operators can track performance and receive alarms from any browser or mobile device. For large projects, the application engineering team supports site design, cable sizing, protection coordination, and grid code filing, helping the customer move from concept to commissioning with a single point of contact.

Packaging Shipping and Support

The KITOZER 40kA type 2 surge protector is packed in a heavy duty plywood crate with foam cushioning and desiccant bags for long sea transit. The crate is labeled with handling symbols, weight, and orientation marks, and it meets ISPM 15 requirements for international shipping. Standard lead time is 15 to 45 days depending on configuration, and rush production is available for urgent projects. Spare parts are held at regional warehouses in Europe, the Middle East, and Southeast Asia, ensuring four to eight hour response time for critical failures. The KITOZER support team provides remote commissioning guidance over video call, and on site commissioning can be arranged for turnkey projects. Every unit ships with a printed quick start guide, a USB stick containing the full user manual in English, and a factory test report. Extended warranty up to 10 years is available on request for mission critical installations.

Price

From $35 per pole. Contact plus 86 13922289957 for three phase complete set pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart