KITOZER 40kA Type 2 Surge Protective Device For Power Panel

Product Overview

The KITOZER 40kA type 2 surge protective device (SPD) protects low voltage switchgear, UPS systems, and sensitive electronics from lightning induced surges and switching transients. The modular plug in design allows each surge module to be replaced without de energizing the panel, and a remote contact signals the building management system when a module needs replacement. The SPD mounts on a standard 35 mm DIN rail and fits easily into new or existing distribution boards.

Technical Specifications

Rated voltage: 230 V or 400 V three phase. Nominal discharge current In: 20 kA 8 by 20 microsecond. Maximum discharge current Imax: 40 kA. Voltage protection level Up: 1.5 kV. Response time less than 25 ns. Pole configuration: 1P, 1P plus N, 3P, 3P plus N, 4P. Remote contact: dry contact, 250 V 0.5 A. Operating temperature minus 40 to plus 85 degrees. Mounting: 35 mm DIN rail. Standards CE, IEC 61643-11, KITOZER 3 year warranty.

Application Scenarios

The type 2 SPD is installed at the main low voltage distribution panel of every commercial building, data center, and factory. It is also fitted at the input of UPS systems, precision air conditioners, and server racks. In lightning prone regions, a type 1 plus type 2 combination SPD is used at the service entrance, and this type 2 unit is installed at the sub distribution panel for additional protection.

Advantages and Features

The plug in module design allows replacement without shutting down the panel, which is critical for 24/7 facilities. The visual window on each module shows green when healthy and red when degraded, so maintenance staff can spot a failed SPD at a glance. The remote contact integrates with the building management system, triggering an alarm before a surge event causes downtime. The low voltage protection level of 1.5 kV ensures connected equipment sees only a small fraction of the incoming surge.

Installation and Maintenance

Mount the SPD base on the DIN rail near the main breaker, connect the line side to the incoming supply, and the load side to the protected busbar. The earth conductor should be as short as possible, ideally under 0.5 m, to minimize lead inductance. Verify the remote contact wiring during commissioning. Inspect the visual window annually and replace any module showing red. Replace all modules after a major surge event, even if the window still shows green.

Price

From $35 per pole. Contact plus 86 13922289957 for three phase complete set pricing.