Table of Contents
ToggleProduct Overview
The KITOZER 40kW upflow water-cooled precision air conditioner is designed for medium-sized data centers, enterprise computer rooms, and industrial process cooling where a chilled water or condenser water loop is already available. By rejecting heat through a water-cooled condenser, the unit eliminates the need for outdoor air-cooled condensers and the long refrigerant piping runs that accompany them. Upflow discharge pushes conditioned air into the ceiling plenum, returning warm air through front or bottom return grilles. The unit combines a brazed-plate water-cooled condenser, heretic scroll compressor, electronic expansion valve, EC supply fans, and a steam humidifier into a single floor-standing cabinet.
Technical Specifications
Nominal cooling capacity is 40kW at 23 degrees Celsius and 50 percent relative humidity, with sensible cooling ratio above 0.95. The unit operates on three phase 400V 50Hz and consumes 13.5kW under full load. Condenser water flow is 8.5 liters per second at 30 degrees Celsius inlet, with a maximum inlet temperature of 40 degrees Celsius. Supply airflow is 9500 cubic meters per hour against 150 Pa external static pressure. Humidification output is 8kg per hour steam. Refrigerant R410A charge is factory set. Dimensions are 1800mm wide by 900mm deep by 2000mm high. Noise level is 68 dBA at 3 meters. The controller supports BACnet, Modbus TCP, and SNMP.
Application Scenarios
This 40kW unit is ideal for 20 to 30 rack server halls, financial core computer rooms, call center data rooms, manufacturing execution system control rooms, and hospital central equipment rooms. It is particularly well suited to buildings where outdoor space is limited, rooftop loading is constrained, or noise regulations forbid large air-cooled condensers. When paired with a cooling tower and dry cooler, the system achieves high energy efficiency during cool seasons through free cooling.
Advantages and Features
Water-cooled design eliminates long refrigerant lines, reducing refrigerant charge and leakage risk. The upflow configuration simplifies ceiling-ducted installations and avoids raised-floor construction constraints. Variable speed EC fans and a digital scroll compressor deliver part-load efficiency exceeding IE4 standards. The intelligent controller rotates compressors across paired units, equalizes run hours, and alarms on filter loading, condenser water temperature drift, and compressor faults. Cascaded alarms can be forwarded to mobile phones via optional communication gateways. The cabinet uses double-skin galvanized steel with 50mm injection foam insulation, preventing condensation on external surfaces.
Installation and Maintenance Recommendations
Piping design should include isolating ball valves, Y-strainers, flexible connectors, pressure and temperature gauges, and a calibrated balancing valve on each unit. Water treatment must be managed to prevent scaling and biological growth in the condenser circuit. A 5 micron filter must be installed upstream of the brazed-plate condenser. Routine maintenance includes monthly visual inspection of condensate drains, quarterly filter pressure differential checks, semi-annual cleaning of the water-side condenser with approved descaling agent, and annual refrigerant leak testing. The humidifier cylinder should be descaled every 6 months in hard water regions.
Price
From $12,600 per unit. Contact plus 86 13922289957 for water-cooled precision AC quotation and drawing package.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com