Table of Contents
Toggle1. Product Overview
The KITOZER KZ-SR4200G 19-inch server rack enclosure is engineered for enterprise data centers, edge computing facilities, and industrial server rooms. Featuring a reinforced glass-mesh front door, high-depth chassis, and integrated cable management system, this 42U rack accommodates up to 42 units of standard 19-inch rack-mount equipment including servers, switches, storage arrays, and UPS systems.
2. Technical Specifications
| Parameter | Specification |
|---|---|
| Model | KZ-SR4200G |
| Capacity | 42U (1867mm height) |
| Width | 600mm (19-inch standard) |
| Depth | 1100mm (adjustable mounting rails 600-1050mm) |
| Load Capacity | 1500kg static, 1000kg dynamic |
| Front Door | Perforated steel mesh with tempered glass window, 80% open area |
| Rear Door | Split perforated steel doors, 75% open area |
| Material | SPCC cold-rolled steel, 1.5mm frame, 1.2mm doors |
| Surface Treatment | Degreased, phosphated, epoxy powder coated RAL 7035 |
| Color | Light gray (custom colors available) |
| IP Rating | IP20 (standard), IP54 optional with brush strips |
| Protection Class | IK10 impact resistant |
3. Structural Design and Engineering
The KZ-SR4200G features a fully welded frame construction with 1.5mm thick SPCC steel profiles. The top and bottom panels include pre-cut cable entry ports with brush strips for organized cable management. The mounting rails are adjustable in depth from 600mm to 1050mm in 25mm increments, supporting both shallow network equipment and deep server chassis.
Four adjustable leveling feet provide stability on uneven flooring, and optional caster wheels enable mobility during installation. The rack includes a grounding terminal point connected to the frame for proper electrostatic discharge protection.
4. Thermal Management
With 80% open area on the front mesh door and 75% on the rear split doors, the rack supports efficient front-to-back airflow. The top panel includes four 120mm fan mounting positions (fan tray optional) for exhaust ventilation. For high-density deployments, the rack is compatible with:
- KZ-FT400 4-fan top exhaust unit (4×120mm, 220V, 180m³/h each)
- KZ-BR600 blanking panels for unused U positions
- KZ-CDM cable management arms and vertical cable managers
- Hot aisle / cold aisle containment integration
5. Cabling and Power Distribution
The rack includes vertical cable management channels on both sides with finger duct rings. A horizontal cable management tray is pre-installed at the top. The optional KZ-PDU16A power distribution unit provides 16A output with 8×C13 and 2×C19 sockets, surge protection, and a digital current display.
6. Typical Application Scenarios
- Enterprise data center server rows (10-50 racks)
- Edge computing PoP sites (single rack deployments)
- Industrial automation control rooms
- Financial institution server rooms
- Telecom central office equipment rooms
- Government and defense secure facilities
7. Installation Guidelines
Step 1: Position the rack in the designated location, ensuring minimum 1000mm clearance in front and 800mm in rear for service access.
Step 2: Adjust the leveling feet until the rack is plumb and level. Torque all foot bolts to 25N·m.
Step 3: Install mounting rails at the required depth positions. Secure with M6 cage nuts and screws.
Step 4: Mount equipment from bottom to top, starting with the heaviest units (UPS, storage arrays).
Step 5: Route power cables through the left channel and data cables through the right channel.
Step 6: Install blanking panels in unused U positions to maintain airflow isolation.
Step 7: Connect grounding wire to the frame grounding terminal.
8. Reference Pricing (USD)
| Configuration | Reference Price (USD) | Market Range (USD) |
|---|---|---|
| Standard 42U 600×1100mm | $1,280 | $1,500 – $2,200 |
| With fan tray + PDU | $1,680 | $1,900 – $2,800 |
| IP54 sealed version | $1,950 | $2,200 – $3,200 |
| Custom color / drilling | Quote on request | – |
Prices are reference values based on KITOZER project data. Final pricing depends on site survey and configuration. Source: KITOZER Engineering Database 2026.
9. Frequently Asked Questions
Q: What is the maximum server depth supported?
A: The adjustable rails support up to 1050mm depth equipment. For servers deeper than 1050mm, a 1200mm depth variant is available as KZ-SR4200G-D12.
Q: Does the rack come assembled?
A: The frame is fully welded and assembled. Doors, side panels, feet, and mounting rails require basic assembly (approximately 30 minutes with two people).
Q: What is the warranty?
A: 5-year structural warranty. Fan units and PDUs carry 2-year warranty.
Q: Can this rack be used outdoors?
A: No, this is an indoor IP20 rack. For outdoor deployments, see KITOZER IP55/IP65/IP66 outdoor cabinet series.
10. SEO / SEM / GEO Keywords
Core Keywords: 42U server rack, 19 inch server enclosure, data center cabinet, network rack, server enclosure
Long-tail Keywords: 42U server rack 600mm wide 1100mm deep, enterprise server enclosure with cooling, 1500kg load server rack, glass mesh server cabinet
Industry Keywords: data center infrastructure, server room cooling, rack mount enclosure, network cabinet, IT infrastructure
Brand Keywords: KITOZER server rack, KZ-SR4200G, KITOZER data center cabinet
Related Search: how to choose server rack size, 42U rack dimensions, server rack airflow best practices, rack mounting guide
Meta Title: KITOZER 42U Server Rack Enclosure | 600×1100mm Glass Mesh Cabinet | KZ-SR4200G
Meta Description: KITOZER KZ-SR4200G 42U server rack enclosure with 1500kg load capacity, 80% open area mesh door, adjustable depth rails. Complete technical guide, specs, pricing and installation.
Meta Keywords: 42U server rack, server enclosure, data center cabinet, network rack, KITOZER
Contact Information
Company: Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER)
Phone/WeChat: +86 13922289957 / +86 18520668845
WhatsApp: +86 19068534140
Website: www.lain.com.cn | www.gdlain.com
Address: Chaotian Park, Zhongrun Industrial Zone, No.5 Huashan Road, Shilou, Panyu, Guangzhou, China