Table of Contents
ToggleProduct Overview
The KITOZER 47U server cabinet in 800 mm width and 1200 mm depth is engineered for high-density data halls where blade servers, storage arrays, and heavy network clusters must be housed in a single bay. The wider 800 mm frame creates room for two vertical cable management ducts, each wide enough for hundreds of patch cords, while the 1200 mm depth accommodates deep chassis, rear door heat exchangers, and extended cable arms. The fully welded steel chassis carries up to 1500 kg of static load, making it suitable for dense storage nodes and large UPS battery packs. Front and rear perforated doors pair with optional roof-mounted fan trays to drive high CFM airflow through the enclosure. The cabinet is designed to interlock side-to-side, so banks of cabinets can be joined into a continuous row with a flat front line. All U positions are numbered on both rails for fast installation, and the frame is grounded at multiple points for reliable safety bonding.
Technical Specifications
Unit height 47U, outer dimensions 2280 x 800 x 1200 mm (H x W x D), 19-inch EIA rails front and rear, rail adjustment depth range up to 1100 mm. Static load capacity 1500 kg, dynamic load 900 kg. Front and rear door perforation 75 percent, lockable with 3-point handle. IP20 standard, IP55 front seal optional. Roof fan tray supports up to six 120 mm fans with thermostat control. Side panels removable and lockable. Bottom entry with four cable glands and brush strips. Top entry with brush plate. Included accessories: leveling feet, heavy-duty swivel casters with brakes, M6 cage nuts and screws, two vertical cable managers, two 1U horizontal lacing bars, ground bolt set. Operating temperature 5 to 40 degrees Celsius, humidity 5 to 95 percent non-condensing. Finish: matte RAL 7035 or RAL 9005, 60 micron powder coat. CE, RoHS tested. Shipping weight 145 kg net.
Application Scenarios
The 800×1200 mm 47U cabinet is the standard enclosure for high-density compute racks in colocation data centers, cloud provider pods, enterprise private cloud halls, and large storage area network rooms. It is the right choice when a single rack must hold blade servers, SAN disk enclosures, top-of-rack switches, and a UPS module in one footprint. The extra width is also preferred by network teams that need to dress hundreds of fiber and copper patch cords without choking airflow. It is commonly used in hot-aisle cold-aisle containment layouts and can be fitted with a rear-door heat exchanger for liquid-assisted cooling. The cabinet also supports GPU compute racks where dual power cords and dense cabling demand the wider duct space.
Key Advantages
The 1500 kg load rating means technicians can fully populate the rack without worrying about frame deflection. The dual vertical cable ducts keep power and data cabling tidy and allow future adds without opening the side panels. The 75 percent perforation ratio minimizes airflow resistance, reducing fan energy use compared with solid-door enclosures. The 3-point locking handles improve physical security and door sealing. The cabinet is designed to interlock side-to-side, so banks of cabinets can be joined into a continuous row with a flat front line. All mounting hardware is included, and the rails are marked with U-position numbers for fast installation. The reinforced base supports heavy concentrated loads from storage shelves. The cabinet is compatible with rear-door heat exchangers and water-cooled manifolds, allowing a smooth path to liquid cooling as density grows.
Installation and Maintenance Recommendations
Because the cabinet weighs over 120 kg when empty, plan floor loading carefully and use a raised floor with rated panels or a concrete plinth. Always bolt adjacent cabinets together into a row before loading equipment. Place the heaviest storage and UPS units on the lowest 10U, distribute network gear evenly, and use ball-bearing sliding rails for any device heavier than 30 kg. Connect the ground bolt to the room grounding bar before energizing equipment. When running power, use one vertical duct for the PDU feed and the opposite duct for data; keep the two bundles at least 50 mm apart. Inspect fan tray brushes every quarter, clean or replace filters, and verify the door gaskets remain intact if the cabinet is used in containment. Re-torque mounting screws after the first 90 days and annually thereafter. Do not exceed 12 kW IT load per rack without adding a rear-door heat exchanger. Keep the containment doors closed to preserve airflow direction.
Price
From $1,180/pc, including casters, leveling feet, cage nuts, and cable managers. Contact +86 13922289957 for volume pricing, rear-door heat exchanger options, and containment integration.