The KITOZER 48V 1kVA communication UPS is a compact line-interactive uninterruptible power supply designed to protect small telecom equipment, network switches, and edge computing nodes from mains outages and power fluctuations. It bridges the gap between simple battery backup and full online double-conversion UPS with a cost-effective, wall-mountable form factor.
Table of Contents
ToggleProduct Overview
The unit integrates a built-in 48V battery pack, a DC-AC inverter, an automatic voltage regulator, and a monitoring controller into a single enclosure. During normal operation, the load runs from regulated mains through the AVR; when mains fails, the inverter switches to battery power in under 10 milliseconds. The front LCD displays input voltage, output load, battery capacity, and runtime estimate.
Technical Specifications
Rated capacity is 1kVA at 0.9 power factor, delivering 900W continuous. Input is 220 VAC single phase, 45 to 65 Hz, with tolerance plus or minus 25 percent. Output is 220 VAC plus or minus 5 percent, pure sine wave, with transfer time under 10 ms. Built-in battery is 48V 7Ah sealed lead-acid, providing 10 to 20 minutes of backup at half load. Communication ports include USB, RS232, and optional SNMP card. Operating temperature is 0 to 40 degrees Celsius. Protection includes overload, short circuit, deep discharge, and overtemperature.
Applications
This UPS protects small 4G and 5G pico base stations, office network switches, CCTV DVR racks, point-of-sale terminals, small server rooms, and industrial control panels. It is also suitable for emergency communication cabinets, retail network closets, and small medical equipment rooms where short outages must be bridged before generator startup.
Advantages and Features
Pure sine wave output safely powers sensitive electronics. AVR compensates voltage sags and surges without draining the battery, extending battery life. Hot-swappable internal battery allows on-site replacement. The monitoring software provides graceful shutdown for connected servers. Compact wall-mount design saves floor space. Low noise operation fits office environments.
Installation and Maintenance
Place the UPS on a flat, ventilated surface or wall-mount it using the supplied bracket. Connect the load to the protected outlets, plug into mains, and charge for 8 hours before first use. Calibrate the battery by running a full discharge test every six months. Replace the internal battery every three to five years. Keep the ambient temperature below 25 degrees Celsius to maximize battery life.