The KITOZER 48V 3kVA online double-conversion UPS delivers premium power protection for telecom racks, small data cabinets, and industrial communication equipment. With continuous AC-DC-AC conversion, the load sees a clean, regulated output regardless of mains disturbances.
Table of Contents
ToggleProduct Overview
The UPS uses a fully digital DSP-controlled double-conversion topology. The rectifier charges the internal battery and supplies the inverter simultaneously, so the load is never exposed to mains switching. A bypass path automatically takes over in case of overload or internal fault. The unit supports parallel redundancy and external battery cabinets for extended runtime.
Technical Specifications
Rated capacity is 3kVA at 0.9 power factor, 2700W continuous. Input is 220 or 380 VAC single or three phase, 45 to 65 Hz, with wide tolerance. Output is 220 VAC plus or minus 1 percent, pure sine wave, with zero transfer time. Efficiency reaches 95 percent online. Internal battery is 48V battery bank supporting 10 to 30 minutes at full load; external cabinets extend to several hours. Communication includes RS232, USB, SNMP card slot, and dry contacts. Operating temperature is 0 to 40 degrees Celsius. Protection includes overload, short circuit, overvoltage, overtemperature, and battery deep discharge.
Applications
This UPS protects 5G base station AC distribution, small data center server racks, network core switches, industrial communication controllers, broadcast transmission equipment, and medical communication devices. It is also used for edge computing nodes, campus network core rooms, and satellite earth station power systems.
Advantages and Features
Double-conversion topology eliminates all mains disturbances including spikes, sags, and harmonics. High efficiency reduces energy waste. Parallel redundancy allows up to three units for N plus 1 protection. The color LCD shows real-time power quality metrics. SNMP integration supports remote monitoring. Hot-swappable bypass switch simplifies service.
Installation and Maintenance
Install on a level floor or standard 19 inch rack, connect protective earth first, then AC input and protected output. Configure battery runtime and alarm thresholds through the front panel. Perform monthly battery checks, quarterly load tests, and annual internal inspection. Replace batteries every three to five years. Keep ventilation gaps on both sides.
Price
From $1,280 per unit, including internal battery. Contact the sales team for extended runtime cabinets.