Table of Contents
ToggleProduct Overview
The KITOZER 500kW central PV inverter is a skid mounted three phase inverter for utility scale solar plants. Housed in a 20 ft outdoor rated container with a built in step up transformer, the skid delivers 500 kW at 10 kV or 35 kV medium voltage. The central inverter topology achieves 99 percent peak efficiency, which is higher than parallel string alternatives. A central control screen shows real time yield, DC voltage, and grid parameters across the whole skid.
Technical Specifications
AC side: three phase 400 V LV, 50 or 60 Hz, 500 kW continuous, with built in 630 kVA step up transformer to 10 kV or 35 kV MV. DC side: two MPPT, 500 to 1500 Vdc, 800 A maximum. Maximum DC input 750 kW. Efficiency 99 percent peak. THDi less than 1.5 percent, power factor adjustable 0.8 to 0.8. Islanding compliant with VDE 0126, IEEE 1547. Communication: dual Ethernet, Modbus TCP, IEC 61850, DNP3. Protection: DC switch, type 2 surge, arc fault, MV protection relay. Enclosure IP54, weight 6500 kg, dimensions 6058 by 2438 by 2896 mm 20 ft container. Standards CE, IEC 62109, KITOZER 5 year warranty.
Application Scenarios
The 500 kW central inverter skid is used at utility scale solar plants from 1 MW to 100 MW, where multiple skids are paralleled at the MV substation. It is also specified at solar plus storage plants, floating solar, and large agrivoltaic installations. The built in MV transformer and switchgear reduce on site engineering to a single MV cable termination, which cuts installation time from months to weeks.
Advantages and Features
Central inverter topology achieves 99 percent peak efficiency, which is 0.3 to 0.5 percent higher than parallel string alternatives. Over a 25 year plant life this translates to millions of kWh of additional yield. The built in MV transformer and switchgear reduce civil works. The skid is precommissioned at the factory, so on site commissioning takes only days. The cloud portal shows per skid yield and supports automated SCADA integration.
Installation and Maintenance
Place the skid on a reinforced concrete pad with crane access. Terminate the MV cable at the built in switchgear, and connect the DC side to the array combiner boxes via a 1000 A DC bus duct. Commissioning requires a factory engineer. Monthly checks cover coolant level, MV insulation, and surge counter readings. Annual service includes heat exchanger cleaning, MV transformer oil test, and firmware update.
Price
From $38,000 per skid including MV transformer. Contact plus 86 13922289957 for multi MW plant EPC pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com