KITOZER 500kW Diesel Generator Parallel Cabinet with Synchronizing Control

Product Overview

The KITOZER 500kW diesel generator parallel cabinet is a synchronizing and load sharing switchboard designed to connect multiple generator sets in parallel for standby or prime power operation. The cabinet houses a dedicated synchronizing controller, generator circuit breakers, main bus ties, and protection relays. KITOZER builds the panel with sections sized for N plus 1 redundancy in data centers, hospitals, factories, and telecom sites. The automatic synchronizing function closes breakers only when voltage, frequency, and phase angle match, preventing mechanical stress on engines and alternators.

Technical Specifications

Rated capacity 500kW per genset, 400V three phase four wire, 50Hz. Synchronizing controller with automatic voltage matching, frequency matching, phase angle check, and close pulse within 5 degrees. Generator breakers 1000A, 3 pole MCCB or ACB with shunt trip and undervoltage release. Main bus 2000A copper, 100kA short time rating for 1 second. Protection: overcurrent, short circuit, earth fault, reverse power, over voltage, under voltage, over frequency, under frequency. Load sharing via analog load share line or digital CAN bus. Communication: Modbus TCP, SNMP, dry contact alarms. Panel IP30, floor standing. Standards IEC 61439, GB 7251, CE.

Application Scenarios

This parallel cabinet is used in data center backup power plants, hospital emergency power, hotel and casino standby, industrial cogeneration, and telecom base station clusters. It also supports peak shaving contracts where generators run in parallel with the grid. N plus 1 configuration allows one generator to be taken offline for maintenance without interrupting critical loads.

For data center and hospital customers, the N plus 1 architecture means that any one generator can be taken offline for scheduled maintenance while the remaining units carry the full critical load. The controller automatically sheds non critical loads if total generation capacity drops below a set threshold, protecting UPS battery runtime. The event log records every start, stop, parallel, and trip with timestamp, which is required for Tier certification audits.

The panel also supports peak shaving contracts where generators run in parallel with the grid during tariff peak hours, reducing demand charges. The controller can be programmed to start generators when grid power exceeds a set threshold and stop them when load drops.

Advantages and Features

Automatic synchronizing eliminates human error and reduces parallelization time to under 5 seconds. Isochronous load sharing distributes kW and kVAr evenly across engines, preventing overload on any single unit. The controller supports base load, peak shaving, and mains failover modes. KITOZER offers options including a 10 inch HMI touchscreen, Web based remote monitoring, and a utility intertie breaker with synchronism check. The panel is prewired and factory tested with simulated generator signals before shipment.

Installation and Maintenance

Place the cabinet on a flat concrete floor with cable entry from bottom. Connect generator power cables, control cables, and battery sensing wires per the schematic. Ensure each generator has its own 4 to 20 mA load share signal. After installation, perform a synchronizing test with two generators at no load, then step load to 25, 50, 75, and 100 percent. Annual maintenance includes breaker mechanical operation test, protection relay secondary injection, and control battery voltage check. KITOZER recommends updating controller firmware during routine service.

Construction and Quality Assurance

The KITOZER parallel cabinet is fabricated from 2mm sheet steel with a powder coated finish. The copper busbar is silver plated at joints and rated for 100kA short time withstand. The synchronizing controller is mounted on a hinged door with a 4.3 inch LCD and push buttons. Every panel undergoes a factory simulated test using a signal generator to simulate generator voltage, frequency, and phase angle. KITOZER provides a FAT report, wiring diagram, and SCADA point list. The panel is prewired and fully tested before shipment, reducing on site commissioning to cable connection.

Packaging and After Sales

The cabinet is shipped in a plywood case with desiccant. KITOZER provides on site commissioning support and operator training. The 2 year warranty covers controller, breakers, and busbar. Spare controllers, breakers, and contactors are stocked. For data center customers, KITOZER offers a 24 hour on site response service contract.

KITOZER offers a range of controller options including base load mode, peak shaving mode, and mains failover mode. In peak shaving mode, the generators run in parallel with the grid and supplement the utility during tariff peak hours, reducing demand charges. In mains failover mode, the generators start automatically on utility failure and take the load within 15 seconds. The controller also supports scheduled weekly exercise testing. The panel can be integrated with a building management system via Modbus TCP or SNMP, allowing remote status monitoring and alarm management.

The 2 year warranty covers controller, breakers, and busbar. Extended warranty up to 5 years is available for critical infrastructure customers.