KITOZER 500kW Diesel Generator Parallel Cabinet with Synchronizing Control

Product Overview

The KITOZER 500kW diesel generator parallel cabinet is a synchronizing and load sharing switchboard designed to connect multiple generator sets in parallel for standby or prime power operation. The cabinet houses a dedicated synchronizing controller, generator circuit breakers, main bus ties, and protection relays. KITOZER builds the panel with sections sized for N plus 1 redundancy in data centers, hospitals, factories, and telecom sites. The automatic synchronizing function closes breakers only when voltage, frequency, and phase angle match, preventing mechanical stress on engines and alternators.

Technical Specifications

Rated capacity 500kW per genset, 400V three phase four wire, 50Hz. Synchronizing controller with automatic voltage matching, frequency matching, phase angle check, and close pulse within 5 degrees. Generator breakers 1000A, 3 pole MCCB or ACB with shunt trip and undervoltage release. Main bus 2000A copper, 100kA short time rating for 1 second. Protection: overcurrent, short circuit, earth fault, reverse power, over voltage, under voltage, over frequency, under frequency. Load sharing via analog load share line or digital CAN bus. Communication: Modbus TCP, SNMP, dry contact alarms. Panel IP30, floor standing. Standards IEC 61439, GB 7251, CE.

Application Scenarios

This parallel cabinet is used in data center backup power plants, hospital emergency power, hotel and casino standby, industrial cogeneration, and telecom base station clusters. It also supports peak shaving contracts where generators run in parallel with the grid. N plus 1 configuration allows one generator to be taken offline for maintenance without interrupting critical loads.

Advantages and Features

Automatic synchronizing eliminates human error and reduces parallelization time to under 5 seconds. Isochronous load sharing distributes kW and kVAr evenly across engines, preventing overload on any single unit. The controller supports base load, peak shaving, and mains failover modes. KITOZER offers options including a 10 inch HMI touchscreen, Web based remote monitoring, and a utility intertie breaker with synchronism check. The panel is prewired and factory tested with simulated generator signals before shipment.

Installation and Maintenance

Place the cabinet on a flat concrete floor with cable entry from bottom. Connect generator power cables, control cables, and battery sensing wires per the schematic. Ensure each generator has its own 4 to 20 mA load share signal. After installation, perform a synchronizing test with two generators at no load, then step load to 25, 50, 75, and 100 percent. Annual maintenance includes breaker mechanical operation test, protection relay secondary injection, and control battery voltage check. KITOZER recommends updating controller firmware during routine service.

Price

From $8,800/pc. Contact +86 13922289957 for parallel panel pricing.