KITOZER
KITOZER

KITOZER Dual Cooling Source Air Conditioner: 50kW Main Standby Switchover

Product Overview

The KITOZER 50 kW dual-cooling-source precision air conditioner combines a direct-expansion refrigeration circuit with a chilled-water coil in a single cabinet. The primary cooling source is the on-board compressor, while the backup source is building chilled water. The controller monitors the primary compressor continuously and automatically switches to chilled-water mode within seconds if a compressor fault, high discharge temperature, or power interruption on the compressor circuit occurs. This design provides true fault-tolerant cooling without buying a fully redundant precision air conditioner, making it popular in tier-2 and tier-3 data halls.

Technical Specifications

DX cooling capacity is 50 kW sensible at 23 degrees Celsius and 50 percent relative humidity. Chilled-water backup capacity is 50 kW at 12 degree Celsius entering water. The unit runs on three phase 400 V 50 Hz with a full-load power draw of 18 kW. Supply airflow is 12,000 cubic meters per hour against 200 Pa. The water coil is a 6-row copper tube aluminum-fin unit rated to 1.6 MPa. Humidifier output is 6 kg per hour steam. Dimensions are 2000 mm wide by 1100 mm deep by 2000 mm high. Weight is 720 kg. The controller supports Modbus TCP, BACnet IP, and SNMP.

Application Scenarios

This dual-source unit is deployed in enterprise data centers, hospital IT rooms, financial back-office computer rooms, and broadcast playout centers where a chiller plant already exists but 24/7 cooling must survive a compressor failure. It is also used in seismic or remote sites where on-site spare parts availability is limited and a second cooling source buys time for maintenance crews to arrive. The unit is equally suited to university research computing rooms and manufacturing execution system control floors. It is also used in offshore platform control rooms and remote telecom sites where on-site spares are scarce and a second cooling source buys time for maintenance crews to arrive.

Advantages and Features

Automatic switchover between sources happens in under 10 seconds, avoiding room temperature excursion. The controller logs every source change, including timestamp and reason. When the chiller plant is running, the unit can be forced into water-only mode to save compressor energy. A motorized ball valve isolates the water coil when not in use. The cabinet uses double-skin construction with 50 mm foam insulation to prevent external condensation. The front door is hinged for tool-less filter and coil access. The controller also supports scheduled start-stop based on building occupancy, avoiding unnecessary cooling during unoccupied hours. A built-in web server exposes live trends and alarm history to any authorized browser on the local network.

Installation and Maintenance Recommendations

Provide both a dedicated power supply for the compressor and a normal power supply for fans and controls. Water piping must include isolation valves, Y-strainer, flexible connector, and balancing valve. Test switchover logic during commissioning by deliberately simulating a compressor fault. Quarterly filter inspection, semi-annual valve actuator calibration, and annual refrigerant leak test are required. Keep a spare modulating valve actuator on site. Operators should be trained on how to force the unit into water-only mode during planned compressor maintenance. A remote alarm forwarding module can send fault messages to a dedicated phone line or email address, so the site team is paged before a small issue becomes a room-temperature excursion. The controller also logs filter differential pressure trends, helping maintenance teams plan replacements during scheduled windows.

Energy and Environmental Performance

Because the chilled-water backup uses no compressor power during normal operation, the unit can run for long periods on water-only mode when the chiller plant is healthy. R410A refrigerant has no ozone depletion potential. The cabinet uses CFC-free foam insulation and is fully recyclable at end of life. The modulating control valve also reduces pump energy by avoiding over-flow at part load. Over a year, the energy savings compared with two fully redundant compressors can be substantial, because the chilled-water backup uses only fan power. The controller also records energy use by mode, so sustainability teams can report annual compressor-off hours.

Configuration Options and Warranty

The unit is offered in multiple airflow sizes and with either R410A or R32 refrigerant where local regulations favor lower GWP fluids. Optional extras include a humidifier, a 4G remote monitoring gateway, a stainless-steel cabinet for coastal sites, and a high-static fan option. The standard warranty covers the compressor for 3 years and the cabinet for 1 year, with extended coverage up to 5 years available. A preventive maintenance package with quarterly visits is available for mission-critical installations. The package includes a filter change, a valve actuator calibration, and a switchover logic test every quarter, ensuring the standby source is always ready.

Price

From $19,800 per unit. Contact plus 86 13922289957 for dual-source precision AC quotation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top