The KITOZER 50 kW open frame diesel generator bridges the gap between small portable units and full industrial gensets, delivering 62.5 kVA standby output for light manufacturing, food processing, hotels, and mid-sized commercial buildings. Mounted on a heavy-duty tubular steel base with integral lifting eyes, the set pairs a turbocharged diesel engine with a Stamford-type or Mecc Alte brushless alternator to produce clean three-phase 400V power suitable for motors, pumps, and electronic loads. The open skid design keeps initial cost down and allows easy fitment of customer-specific fuel tanks, battery chargers, and connection to an upstream ATS panel. It is a popular choice for projects where the generator room is already enclosed and acoustic treatment is handled locally.
Table of Contents
ToggleTechnical Specifications
Standby 55 kW (68.75 kVA), prime 50 kW (62.5 kVA), 400V 50Hz three-phase four-wire, voltage regulation plus or minus 1 percent. Engine: water-cooled, four-stroke, turbocharged, direct injection, 1500 rpm at 50 Hz. Alternator: brushless, self-excited, AVR, class H, IP23. Control panel: digital deep-sea or ComAp equivalent with LCD, USB programming, Modbus RS485. Sub-base fuel tank 180 L to 250 L, autonomy at 75 percent load around 10 to 14 hours. Circuit breaker: 125A three-phase MCCB. Battery 12V 100Ah. Dimensions approximately 2000 x 850 x 1200 mm, dry weight 1100 to 1400 kg. Noise 90 to 95 dB(A) at 7 m open.
Key Advantages
The 50 kW class is one of KITOZER best-selling configurations because it balances fuel economy, footprint, and price. The electronic engine governor holds frequency within plus or minus 1 percent during step loads of up to 50 percent, protecting sensitive equipment such as PLCs, CNC controllers, and POS networks. The digital controller records up to 100 event logs and can be configured for remote start via dry contact or MODBUS, making it compatible with building management systems and IoT monitoring platforms. Engineers can select a Chinese engine for budget-sensitive markets, a Japanese engine for long-life prime power duty, or a European engine for emission-regulated regions.
Applications
Common installations include auto repair shops running compressors and exhaust fans, small bakeries and restaurants with refrigerated display cases, hotels with 50 to 80 rooms, supermarkets supporting lighting and checkout systems, and agricultural irrigation pumping stations. Construction contractors use the set to power tower cranes, site offices, and concrete batching plants during grid interruptions. The 50 kW rating is also well matched to small data closets, security systems, and water treatment plants in residential developments. Because the open frame allows easy connection, it is frequently installed inside a purpose-built generator room with its own ventilation, fuel tank, and acoustic enclosure built by the local contractor.
Installation and Maintenance
Foundation should be a reinforced concrete plinth sized to at least 1.2 times the generator footprint and 200 mm thick, with anti-vibration mounts inserted between the skid and the plinth. Air inlet and outlet openings must be sized for at least 12 m2 per 100 kW of engine cooling capacity. Exhaust piping should be insulated and supported independently to avoid stress on the turbocharger. Fuel lines use seamless steel hose with a flexible section at the engine connection. For ATS operation, wire the start stop terminals and the common alarm contact to the transfer panel; KITOZER provides a terminal diagram with every unit.
Routine maintenance includes oil and filter change at 250 hours, fuel filter at 500 hours, coolant analysis annually, and valve clearance check at 2000 hours. Exercise the set weekly under 30 percent load for 30 minutes, and perform an annual load bank test at 100 percent rated power for one hour to confirm capacity. Keep a logbook of running hours, fuel consumption, and fault events. KITOZER recommends storing a spare set of filters, belts, glow plugs, and fuses on site for critical standby sites.
Packaging and Shipping
The open frame generator is wrapped in stretch film, protected with foam on gauges and alternator, and strapped to a fumigated steel skid with lifting eyes. KITOZER factory-load-banks every unit and provides a performance certificate before shipment. Export documents include CE certificate, factory test report, commercial invoice, packing list, and origin certificate. KITOZER can arrange container loading, CIF delivery, and engineer commissioning on site.
Quality Assurance and Warranty
Every KITOZER product undergoes a strict factory inspection process before shipment. The engine is run in and load-tested, the alternator winding resistance and insulation are measured, the control panel is functionally checked, and the complete set is operated under load bank for at least one hour. KITOZER provides a 12-month warranty from shipment or 1000 running hours, whichever comes first, covering manufacturing defects in engine, alternator, and control panel. Spare parts, filters, belts, and fuses are stocked for rapid dispatch. The KITOZER technical team provides remote troubleshooting support over email, WeChat, or WhatsApp, and can dispatch an engineer to site for critical projects.
KITOZER engineering can tailor the set to specific site conditions: cold climate kits with jacket water heater, oil pan heater, and battery blankets; tropical kits with larger radiator and desert-grade air filters; coastal kits with C5-M paint and anti-corrosion anodes; and emission-compliant kits for regulated markets. The factory also offers extended warranty, annual service contracts, and remote monitoring subscriptions that stream runtime, fuel level, and alarms to a cloud dashboard.
Price
From $9,800 per unit for the 50 kW open frame set. Contact KITOZER for engine brand selection, alternator options, control panel upgrade, and export CIF pricing. Tel/WeChat: +86 13922289957.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com