The KITOZER 50kWh lithium iron phosphate battery cabinet is a plug-and-play energy storage unit for residential, small commercial, and solar self-consumption systems. It integrates LFP battery modules, a battery management system, thermal management, and DC protection in a floor-standing enclosure, pairing with 5kW or 10kW hybrid inverters. The cabinet is designed for indoor or ventilated outdoor installation and delivers safe, long-cycle energy storage for off-grid and grid-tied solar systems. The modular design allows the owner to start with one cabinet and add more later as load grows.
Table of Contents
ToggleProduct Overview
The cabinet uses 51.2V LFP battery modules connected in series to form a 400V to 480V DC bus. Each module contains 16 cells with integrated cell balancing and temperature sensing. The master BMS monitors voltage, current, and temperature of every cell, and communicates with the hybrid inverter over CAN bus. A built-in fire detection and gas exhaust duct provides an additional safety layer, and the cabinet door includes a vent that directs gas outside in the rare event of thermal runaway.
The DC distribution inside the cabinet includes a main breaker, a pre-charge resistor, and a contactor, all controlled by the BMS. A front LCD displays state of charge, current, cell voltage, and alarm history. The cabinet ships charged to about 30 percent state of charge, ready for commissioning. Up to five cabinets can parallel on a single inverter for 250kWh of storage, and the parallel connection is daisy-chained with standard CAN cables.
Technical Specifications
Rated energy 50kWh, usable 47.5kWh. Nominal voltage 400V DC, voltage range 350 to 490V. Continuous charge and discharge current 50A, peak 100A for 30 seconds. Round-trip efficiency more than 95 percent. Cycle life 6000 cycles at 80 percent depth of discharge. Battery chemistry LFP (LiFePO4). Communication CAN 2.0B, RS485. Protection IP20 indoor, optional IP54 outdoor cabinet. Operating temperature charge 0 to 50 degrees Celsius, discharge -20 to 55. Dimensions 700x600x1200mm, weight 380kg. Certifications CE, IEC 62619, UN38.3. KITOZER brand, 5-year warranty or 6000 cycles.
Applications
This cabinet suits villas, small shops, farms, and rural households with rooftop PV who want overnight self-consumption or backup power. It is also used in small office buildings, telecom cabinets, and lighting and CCTV systems where grid reliability is weak. Multiple cabinets can parallel to scale energy from 50kWh to 200kWh on a single inverter. In off-grid cabins and remote monitoring stations, the cabinet pairs with a small diesel generator to reduce runtime and fuel cost.
Advantages and Features
LFP chemistry offers intrinsic thermal stability and 6000-cycle life, outlasting NMC chemistry in daily cycling. The modular design allows a faulty module to be swapped without removing the whole cabinet. The BMS provides cell-level balancing, overvoltage, undervoltage, overcurrent, and overtemperature protection. A front LCD shows state of charge, current, and alarm history. No leak risk and no ventilation requirements for indoor use beyond basic airflow.
The cabinet supports both high-voltage and low-voltage inverter configurations, giving integrators flexibility. The BMS can be configured for most mainstream hybrid inverters via a simple parameter list. A built-in heater option allows operation down to -30 degrees Celsius, which is useful in cold climates. The cabinet includes a smoke detector that triggers an external alarm contact, and the gas exhaust duct connects to outside air. The mechanical design allows forklift handling and has integrated lifting eyes for crane installation.
Installation and Maintenance
Place the cabinet on a level floor in a cool, dry room with temperature between 15 and 30 degrees Celsius for longest life. Keep 500mm clearance in front and 200mm on sides. Connect DC cables to the hybrid inverter with correct polarity and torque to the inverter specification. Use shielded CAN cable routed away from AC power cables. Commission by reading BMS alarms, checking cell voltage spread, and running a full charge and discharge cycle.
Maintenance includes quarterly state of health inspection, annual connector torque check, and fan filter cleaning. Store spare modules in a dry area at 50 percent state of charge. If a module alarm occurs, record the cell voltages from the BMS screen and send them to KITOZER support. The BMS keeps a fault log of the last 100 events, which helps diagnose intermittent issues. In dusty or humid environments, inspect the door gasket and filters twice a year.
Quality and Reliability
Every KITOZER battery module passes a full capacity test at the factory, and the measured capacity is recorded on a label and in the BMS. Each cabinet undergoes a 24-hour burn-in test that cycles charge and discharge twice, verifying contactor operation, balancing, and communication. The cells are grade A LFP prismatic cells from reputable manufacturers, matched to within plus or minus 20mAh capacity. The cabinet is shipped with a detailed test report, wiring diagram, and quick-start guide in English.
Price
From $5,980/cabinet. Contact +86 13922289957 for 50kWh storage system price and inverter pairing support.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com