KITOZER In-row Air Conditioner: 60kW Chilled Water Type

Product Overview

The KITOZER 60kW chilled-water in-row air conditioner is a compressor-free rack-height terminal unit designed for data halls served by a central chiller plant. It uses a high-capacity cooling coil, modulating control valve, EC plug fan array, and optional steam humidifier. Chilled water enters at 10 to 14 degrees Celsius and absorbs heat directly from hot aisle exhaust air. Because no refrigeration circuit lives inside the white space, the unit is quiet, reliable, and easy to service without refrigerant handling certification.

Technical Specifications

Rated sensible cooling is 60kW at 27 degrees Celsius entering air, 50 percent relative humidity, and 10 degree Celsius entering water. Coil is 6-row copper tube with aluminum fins, rated to 1.6 MPa working pressure. Water flow is 2.6 liters per second at a design delta-T of 5 degrees. Supply airflow is 14,000 cubic meters per hour against 80 Pa. Electrical supply is three phase 400V 50Hz with fan power 2.2kW and humidifier 6kW. Dimensions are 600mm wide by 1200mm deep by 2000mm high. Weight is 280kg. Noise is 64 dBA at 3 meters. Communication supports BACnet IP, Modbus TCP, and SNMP.

Application Scenarios

This unit is deployed in colocation halls, enterprise data centers, and cloud zones where chilled water is already distributed. It suits rack densities of 10 to 20kW per rack, GPU compute clusters, and storage arrays. It pairs naturally with hot-aisle containment and water-side economizers, allowing free cooling whenever outdoor temperatures permit the chiller to unload.

Advantages and Features

The absence of compressors eliminates refrigerant leak risk inside the data hall and removes the dominant source of acoustic noise. The 0 to 10V modulating valve adjusts water flow down to 10 percent, maintaining stable aisle temperatures under rapidly changing IT loads. EC fan arrays deliver high efficiency and redundancy: loss of one fan leaves the rest continuing to supply cooling. The controller integrates with DCIM platforms, providing per-unit kilowatt metering, filter loading alarms, and condensate overflow protection.

Installation and Maintenance Recommendations

Piping must include isolation valves, Y-strainer, flexible connector, and balancing valve. A drain pan with float switch and lift pump protects against condensate overflow. Air filters are G4 and should be inspected quarterly. The coil should be chemically cleaned at commissioning and inspected annually. Valve actuators and temperature sensors require annual calibration. Water quality must be maintained to prevent fouling of the coil.

Price

From $11,800 per unit. Contact plus 86 13922289957 for chilled-water in-row pricing and hydraulic layout.