KITOZER
KITOZER

KITOZER 64-Point Environmental Monitoring Host For Data Hall

The KITOZER 64-point environmental monitoring host is the mainstream choice for single-row to single-zone data halls hosting 60 to 150 racks. It unifies environmental, security, and electrical auxiliary signals on one IP controller, reducing the number of small brand panels that integrators would otherwise stack in a corner. With four isolated RS485 buses and a rich protocol stack, the host plugs directly into DCIM, BMS, and enterprise alarm platforms. Local storage holds more than a year of event and trend data, so engineering teams can review thermal trends after hot-aisle containment changes without waiting for the central server.

Product Overview

The 64-point host uses a fanless quad-core industrial computer with a solid-state drive, 4GB RAM, and a 5 inch color touchscreen. Four RS485 buses support up to 32 sensors each, while six relay outputs and twelve digital inputs interface with CRAC units, smoke detectors, magnetic contacts, and UPS dry contacts. The onboard software supports auto-discovery of KITOZER sensors, drag-and-drop floor plans, and scheduled screenshots emailed to management. A built-in cellular modem option lets the host report alarms even when the wired LAN is down.

The touchscreen runs a lightweight web-compatible UI, so the same configuration logic used on a desktop browser works locally. Auto-discovery scans each bus and lists new sensor addresses, which cuts commissioning time on a 64-channel site from days to hours. Floor plan graphics let operators drag a rack icon onto a map and attach sensors to it, producing a visual alarm view that helps new hires learn the room quickly. The SSD-based event log survives power loss and supports million-record ring buffer without mechanical wear.

Technical Specifications

Channels: 64 points across four isolated RS485 buses, 12 digital inputs, 6 relay outputs. Compute: quad-core ARM, 4GB RAM, 64GB SSD. Display: 5 inch color touchscreen, 800 by 480. Networking: two gigabit Ethernet, optional 4G LTE modem, Wi-Fi. Protocols: Modbus TCP and RTU, SNMP v3, BACnet IP, MQTT, OPC UA, SMTP, Syslog, HTTPS. Power: 10-36V DC with redundant terminals and 1A UPS backup output. Event log: 1 million records on SSD. Operating range: -20 to 60 degrees Celsius, 5 to 95 percent RH. Enclosure: metal wall or rack mount, IP30. Certifications: CE, FCC, RoHS, UL listed option. Warranty: 5 years.

OPC UA support makes the host a natural edge node for manufacturing execution systems and IIoT platforms, while BACnet IP covers the building automation side. The 4G modem uses a standard SIM and reports over HTTPS, so no special VPN is needed for remote sites. Redundant power terminals accept two 24V feeds, and a built-in 1A output can power a small sensor string from the same supply. The fanless design has no moving parts, which is why the warranty stretches to five years.

Application Scenarios

Typical use covers data halls with hot-aisle containment, where temperature sensors monitor every rack inlet, humidity sensors sit at row ends, leak rope runs around CRAC units, and door contacts watch the containment doors. The host also fits manufacturing clean rooms where temperature drift, particle alarms, and access must be correlated. In healthcare, it monitors pharmacy cold rooms, MRI equipment cooling, and generator battery rooms. Colocation providers use it as tenant-facing alarm gateway because it supports virtual channels per customer group without separate hardware.

In semiconductor packaging plants, the host ties clean room temperature and humidity to the process execution system, so a humidity excursion halts the line before wafers are damaged. In pharmaceutical fill-finish suites, it logs environmental parameters for GMP batch records. In museum storage, it protects art from humidity-driven mold and from unauthorized door access. Each of these regulated environments benefits from the million-record local log and the tamper-evident audit trail.

Key Advantages

Four isolated buses let integrators dedicate one bus per aisle or per CRAC group, which shortens cable runs and simplifies troubleshooting. OPC UA and MQTT make the host a natural edge node for IIoT platforms. The touchscreen removes the need for a tablet during commissioning. Onboard SSD logs survive power loss, while redundant power inputs keep the host alive through transfer-switch events. The optional 4G modem provides a last-mile alarm path for remote sites where primary network failure is the exact event being detected.

Virtual channel grouping means a colocation operator can show tenant A only the sensors in their cage, even though all hardware shares one panel. Auto-discovery and drag-and-drop floor plans reduce engineering hours on every project. The fanless SSD design has no bearing life limit, so maintenance teams can ignore the host itself except for firmware updates.

Installation and Maintenance

Rack-mount the host in the top of the row so the touchscreen is reachable without opening a live cabinet. Assign each RS485 bus a logical zone and label cable jackets accordingly. Use a separate 24V DC UPS just for the host and its sensors so cooling fan relay logic survives a brief drop. Configure NTP and send Syslog to the central SIEM so alarm timestamps correlate across sites. Every six months, review trend reports to spot slow sensor drift before thresholds are breached. Replace the RTC battery every five years.

Price

From $1,850 per unit including touchscreen, four-bus license, and OPC UA. Contact +86 13922289957 for project quotation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top