The KITOZER 8-zone water leak controller centralizes up to eight independent sensing loops in one wall-mount panel. Each zone can carry a non-locating rope, a locating cable, or a point water spot detector, and the controller reports status over relay outputs and RS485 Modbus. The front panel LEDs show the active zone, while the onboard buzzer and mute button give local staff immediate feedback during after-hours events.
Table of Contents
ToggleProduct Overview
Built around a 32-bit industrial MCU, the controller scans each zone every second and distinguishes between open circuit fault, short circuit, and water leak. The modular design lets installers start with 4 zones and expand to 8 by adding an I/O card. A built-in web page option (on the Ethernet variant) allows remote status checks and email alarms. Power input accepts 9 to 36V DC, and the relay contacts are rated for direct siren or damper control.
The supervised zone input measures the resistance on the loop continuously. A normal loop sits at a known resistance set by the end-of-line resistor. When water bridges the braid, resistance drops and the controller raises a leak alarm. When the wire breaks, resistance goes to infinity and the controller raises a fault alarm. This three-state logic is the key difference from cheap panels that cannot tell a leak from a broken cable.
Technical Specifications
Zones: 8 expandable, each supporting up to 100m non-locating rope, 200m locating cable, or point sensor. Inputs: supervised, detects open, short, and wet states. Outputs: 8 SPDT relays, 5A 250VAC. Communication: RS485 Modbus RTU, optional Ethernet with Modbus TCP and SMTP. Power: 9-36V DC, 12V 1A typical. Enclosure: ABS wall mount, IP30. Display: 8 zone LEDs, power and fault LED, buzzer with mute. Operating: -10 to 60 degrees Celsius. Certifications: CE, RoHS. Warranty: 3 years.
The Ethernet variant runs a tiny web server that serves a status page showing all zones, relay states, and event log. SMTP settings allow the controller to email a distribution list on alarm, so no separate alarm server is needed for small sites. Modbus TCP exposes the same registers as the RTU port, so existing SCADA drivers work without modification. The buzzer has a mute button but re-arms automatically when the alarm clears, preventing staff from silencing it and forgetting.
Application Scenarios
The controller fits medium data centers with several CRAC units, hospital equipment rooms, manufacturing clean rooms, and hotel back-of-house plumbing zones. Zone 1 protects under CRAC 1, zone 2 under CRAC 2, zone 3 along the chiller pipe, and so on. When a relay closes, the BMS starts the exhaust fan and sends a ticket to maintenance. In multi-building campuses, Ethernet variants email the facilities team directly, eliminating the need for a separate alarm server.
In retail headquarters, the controller protects the server room, the battery backup closet, and the roof top AC units from one panel. In school labs, it monitors under the autoclave and the distilled water loop. In hotel basements, it watches the laundry drain pan and the boiler water feed. The mixed support for rope, cable, and point sensors means one panel covers every leak geometry in the building, which simplifies the bill of materials.
Key Advantages
Supervised inputs distinguish real leaks from broken wires, which eliminates the classic nuisance-false-alarm cycle. The expandable card design lets projects grow without replacing the panel. Mixed support for rope, cable, and point sensors means one controller covers every leak geometry on site. Relay outputs drive sirens and dampers without external logic. The Ethernet option turns the panel into a self-contained alarm sender for small sites.
The three-state supervised input is the most important technical advantage: it prevents the two failure modes that have given leak detection a bad name. The expandable design means a 4-zone project grows to 8 zones by adding a card, not a new panel. The web and email option removes the need for a separate alarm server. The DIP-switch address and the mute button are details that technicians appreciate on a 2 AM call. For multi-building sites, the Ethernet variant becomes the local alarm sender, and the central DCIM polls it once a minute for status. When selecting, choose the RS485 version for a single panel on a local bus, and the Ethernet web version for small sites that need email alarms without a central server.
Installation and Maintenance
Mount the controller near the room entry at eye level. Terminate each zone loop with the supplied end cap and record the zone-to-area mapping on the door label. Wire relay contacts to sirens and BMS inputs in parallel. Test each zone after commissioning and quarterly thereafter. If a zone shows fault, walk the loop looking for crushed cable or loose splice. Back up configuration on the Ethernet variant after every change.