ToggleProduct Overview
The KITOZER 80 kW chilled-water precision air conditioner is a terminal air handler designed for large data centers and hyperscale halls that already operate a central chiller plant. The unit contains no compressor, using instead a galvanized-steel coil fed by 7 to 12 degree Celsius chilled water, a modulating control valve, EC plug fans, steam humidifier, and a high-resolution touchscreen controller. Removing the refrigeration circuit from the white space eliminates refrigerant leaks inside the data hall, reduces heat rejection load, and lowers maintenance risk. The unit is available in downflow, upflow, and horizontal discharge variants to match raised-floor, ceiling-plenum, and ducted layouts. A drip-tray heater and integrated lift pump protect against water spillage during condensate overflow events.
Technical Specifications
Rated cooling capacity is 80 kW sensible at 23 degrees Celsius, 50 percent relative humidity, with 10 degree Celsius entering water. The coil is a 6-row copper tube with aluminum fins, tested to 1.6 MPa working pressure. Chilled water flow is 3.4 liters per second at design delta-T of 5 degrees. Supply airflow is 18,000 cubic meters per hour against 250 Pa external static pressure. Electrical supply is three phase 400 V 50 Hz, with fan motor power 4.5 kW and humidifier 9 kW. Actuator valves are 0 to 10 V modulating. Dimensions are 2400 mm wide by 1100 mm deep by 2000 mm high. Weight is approximately 680 kg. Noise level is 72 dBA at 3 meters. The controller supports BACnet IP, Modbus TCP, and SNMP with per-unit kilowatt metering.
Application Scenarios
This unit is deployed in large enterprise data centers, colocation facilities, cloud computing halls, semiconductor cleanroom support rooms, and broadcasting master control rooms. It pairs naturally with centrifugal or screw chillers and thermal storage tanks, and is often sequenced with air-side or water-side economizers to exploit cold-weather free cooling. Dual-utility N plus N configurations are typical in mission-critical halls, where units are distributed evenly across the floor to balance hot and cold aisles. It is also used in museum climate zones, hospital pharmacy cold rooms, and television playout centers.
Advantages and Features
Without compressors in the white space, the unit is nearly silent and free of vibration, making it suitable for office-co-located data halls. The modulating control valve provides precise water flow control down to 10 percent of design, stabilizing room temperature under fluctuating IT loads. EC fans offer 30 to 40 percent energy savings over AC equivalents. The controller integrates with BMS through BACnet IP and supports scheduling, setpoint drift alarms, and filter loading trends. A built-in condensate pump and drip-tray heater protect against shutdown events. Front-serviceable filters and coil sections reduce mean time to repair. The unit also supports floating supply temperature setpoints that rise when IT load is low, allowing the central chiller to produce warmer water and save energy. A built-in web server lets operators view trends and adjust setpoints from a browser without installing dedicated software.
Installation and Maintenance Recommendations
Piping must include isolation valves, Y-strainer, flexible connector, drain and vent cocks, and a calibrated balancing valve. Coils should be chemically cleaned at commissioning and pressure-tested before insulation. Air filters are G4 standard with optional F7 upgrade; differential pressure switches trigger replacement alarms. The condensate pump and float switch should be tested quarterly. Valve actuators and temperature sensors should be calibrated annually. Coil fin cleaning every two years maintains airflow and heat transfer efficiency. Water quality monitoring on the chilled water loop prevents biological fouling inside the coil. Commissioning should include a pressure test on the water circuit, a balancing procedure that sets flow to design delta-T, and a 24-hour test that verifies valve response to step changes in room temperature. Operators should be trained on reading the touchscreen, acknowledging alarms, and replacing filters before handover.
Energy and Environmental Performance
Because the unit contains no compressor, its only parasitic energy is the fan power, which averages less than 6 percent of the heat it rejects. This is a major advantage in PUE-optimized data halls, where every kilowatt of cooling overhead is scrutinized. When paired with a water-side economizer, the central chiller can be bypassed for most of the year, pushing site PUE below 1.25. The cabinet uses CFC-free foam insulation and is fully recyclable at end of life.
Configuration Options and Warranty
The air handler is offered in multiple coil rows, with 4, 6, or 8 row configurations to match chiller water temperatures. Fan arrays can be sized for external static pressure up to 500 Pa for ducted installations. Optional extras include a steam humidifier, an electric preheat coil, a UV disinfection lamp, and a BACnet routing module. The standard warranty covers the cabinet and controls for 1 year, with extended coverage up to 5 years available. Factory commissioning and operator training are available on request.