KITOZER Active Harmonic Filter: 150A AHF Power Quality

The KITOZER 150A active harmonic filter (AHF) is an IGBT-based power quality device that injects canceling currents in real time to suppress harmonic distortion, correct power factor, and balance unbalanced loads. Unlike passive filter banks, which are tuned to fixed frequencies, the AHF continuously measures load current, extracts harmonic components, and generates inverse currents that cancel them. This makes it effective across a wide harmonic spectrum and adaptable to changing loads. KITOZER supplies the AHF in rack and floor-standing cabinets for data centers, industrial plants, and commercial buildings with high nonlinear load content.

Technical Specifications

Rated voltage 400V three phase, rated compensation current 150A, frequency 50Hz, harmonic filtering range 2nd to 50th, THDi reduction to below 5%, power factor correction to 0.99 leading or lagging, load balancing capability. IGBT voltage source inverter, switching frequency around 10kHz, response time below 10ms. Parallel operation up to 20 units. Communication: Modbus TCP, SNMP, Web HMI. Cooling: forced air. Cabinet IP20. Conforms to IEC 61000 and IEEE 519. KITOZER, 5 year warranty on power modules.

Applications

The KITOZER 150A AHF is installed on the low-voltage busbar of data centers, hospitals, financial trading rooms, and industrial plants where UPS systems, VFDs, LED drivers, and switched-mode power supplies generate harmonic current. It reduces transformer overheating, neutral conductor overloading, and malfunction of sensitive electronic equipment. In manufacturing plants with rectifiers and welders, the AHF suppresses voltage distortion that would otherwise affect measurement instruments and process controls.

The AHF can be used as a stand-alone power quality solution or alongside passive capacitor banks, where it also suppresses resonance between capacitors and the grid. It is ideal for facilities that must meet IEEE 519 or G5/4 harmonic limits at the point of common coupling. In multi-tenant commercial buildings, a single AHF on the main switchboard mitigates aggregate harmonic distortion from many individual tenant loads.

Key Advantages

Active filtering adapts to changing loads and filters all harmonic orders simultaneously, unlike fixed-tuned passive filters that work only at designed frequencies. The AHF also provides dynamic reactive compensation and load balancing, so one device addresses multiple power quality issues. Parallel scaling means capacity can be added as load grows without replacing the existing unit. KITOZER modules are hot-swappable, allowing replacement without shutting down the filter or the load.

The Web HMI and Modbus TCP give operators real-time visibility of voltage, current, THD, and compensation status. Event logs record trips and faults for diagnostics. The AHF does not create parallel resonance with the grid, because it is an active device rather than a passive LC circuit. This makes it safer than passive filters in weak or variable grids.

Installation and Maintenance

Connect the AHF in parallel with the load on the low-voltage busbar through a dedicated feeder breaker. Install the current transformer at the point where the aggregate load is measured, because the AHF uses this CT signal to derive the harmonic reference. Ensure adequate ventilation around the cabinet and connect the earthing system. Commissioning software allows selection of target harmonics, reactive compensation mode, and balancing mode.

Routine maintenance consists of cleaning air filters, checking fan operation, and inspecting DC bus capacitors. The Web HMI reports module health and alarms, so failed modules can be replaced during a maintenance window. Keep spare power modules and fans on site. Do not exceed the recommended short-circuit level at the point of connection, because the inverter must withstand fault current until the upstream breaker trips.

KITOZER offers the active harmonic filter in ratings from 30A to 300A per cabinet, with up to 20 units paralleled for larger installations. It can be configured for harmonic filtering only, for combined harmonic and reactive compensation, or for combined harmonic, reactive, and load balancing. When ordering, specify the rated voltage, the required compensation current, the dominant harmonic orders, and whether reactive compensation or balancing is needed. KITOZER performs a power quality survey before sizing the filter, because the required current depends on the measured THDi and the existing power factor. The filter is factory-tested and shipped ready for parallel connection. Spare power modules and fans are recommended as critical spares, and hot-swap design means a module can be replaced without shutting the filter down. The Web HMI records harmonic trends and event logs, which can be used to demonstrate compliance with IEEE 519 or local utility harmonic limits. KITOZER also provides commissioning support and power quality verification after installation to confirm that THDi is brought within the required target.

KITOZER can supply the AHF as a stand-alone cabinet or integrated into a power quality row. Factory test reports and configuration files accompany each unit. Common current ratings are held in stock for short lead times, and KITOZER provides post-installation power quality verification.

Price

From $9,800/pc. Contact +86 13922289957 for AHF sizing and parallel configuration.