Table of Contents
ToggleProduct Overview
The KITOZER Analog Input Module 8CH 16-bit is a high-precision signal acquisition unit for PLC and remote IO systems that need to read temperature, pressure, flow, level, and weight transmitters in harsh industrial environments. Eight channels are software-configurable for 4 to 20 mA, 0 to 10 V, 0 to 5 V, PT100, PT1000, and thermocouple types, so a single module can handle mixed transmitter types across a machine. Each channel is optically isolated to 2500 V AC from the backplane, protecting the PLC from ground loops and sensor surge events. The 16-bit resolution and 0.1% accuracy support closed-loop PID control and accurate flow totalization without external signal conditioners. KITOZER builds the module with a 24-bit sigma-delta ADC per channel and a 50/60 Hz notch filter that rejects line noise common in plants with VFDs and welders. Every module is calibrated at the factory with traceable standards and shipped with a calibration certificate.
Technical Specifications
The module operates from 24 V DC at 120 mA, and mounts on the KITOZER modular backplane or standalone DIN rail via the EtherCAT or Modbus RTU adapter. Eight channels each support 4 to 20 mA input loop power, 0 to 10 V voltage input, PT100 two-wire or three-wire RTD, PT1000, and J, K, T, E thermocouple types. Resolution is 16 bits for current and voltage, 0.1 degrees Celsius for RTD, and 0.5 degrees Celsius for thermocouple. Accuracy is plus or minus 0.1% of reading at 25 degrees Celsius, with temperature drift of 50 ppm per degree Celsius. Channel-to-channel isolation is 2500 V AC, and backplane-to-field isolation is also 2500 V AC. Common-mode rejection ratio is 86 dB at 50/60 Hz, and sampling rate is 10 samples per second per channel. Operating temperature is -20 to +60 degrees Celsius, and the housing is 35 mm wide for DIN rail mounting.
Application Scenarios
Typical uses include water treatment plants reading pressure, level, and flow transmitters; food and beverage machines measuring oven temperature with PT100 probes; HVAC systems reading duct pressure and outdoor air temperature; chemical batching stations reading load cells and pH transmitters; and energy management panels reading smart meter 4 to 20 mA outputs. In water treatment, the module connects to pressure transmitters on each pump skid and uploads readings to the SCADA over Modbus TCP. In oven control, PT100 channels feed PID loops that modulate SSR outputs to hold temperature within plus or minus 1 degree. In batching, the 4 to 20 mA channels read load cell transmitters and trigger valve shutoff at target weight. KITOZER also supplies the module for retrofits of legacy DCS systems that need additional analog points without replacing the main controller.
Advantages and Features
The mixed-signal configuration is the primary advantage: one module replaces separate current, voltage, RTD, and thermocouple cards, simplifying spares inventory. Per-channel isolation eliminates ground-loop errors that otherwise force analog re-ranging or signal conditioner boxes. The onboard 50/60 Hz notch filter reduces noise pickup from VFDs, and the 24-bit ADC provides headroom for slow, high-resolution measurements such as tank level. Factory calibration with traceable certificate means integrators do not need to perform field calibration on delivery. The module auto-detects on the KITOZER backplane and presents channel data in standard PLC tags, reducing engineering time. Diagnostics include open-circuit detection on 4 to 20 mA loops, over-range flags, and broken RTD detection. KITOZER backs the module with a 5-year warranty and a regional spare parts stock.
Installation and Maintenance Recommendations
Mount the module on the DIN rail away from VFDs and contactors, and route analog cables in shielded twisted pair inside a dedicated conduit. Ground the shield at one end only, at the cabinet earth bar, to avoid ground loops. For 4 to 20 mA loops, verify the transmitter loop voltage is above 12 V at the module terminals. For RTD wiring, use three-wire connection to cancel lead resistance, and match the wire gauge to the sensor distance. During commissioning, use the configuration utility to set each channel type and range, and read back raw counts to verify wiring. Perform a one-point calibration with a known simulator during the first month of operation. For maintenance, inspect the shield grounding annually, re-calibrate every two years against a traceable source, and keep a spare module on site. When replacing a module, record the channel configuration in the project file so the new unit can be loaded in minutes.
Price
From $460/module. Contact +86 13922289957 for analog input pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com