KITOZER
KITOZER

KITOZER Anti-Static Raised Access Floor: All-Steel HPL PVC Complete Guide

KITOZER All-Steel Anti-Static Raised Access Floor: Complete Guide

KITOZER Anti-Static Raised Access Floor

1. Definition and Overview

Anti-static raised access floor (also called electrostatic discharge floor, raised floor, or access floor) is a flooring system installed above the original floor in computer rooms, data centers, control rooms, and cleanrooms. Pedestals support floor panels at a height of 150-500mm, creating a plenum space for cables, air conditioning ducts, and fire protection piping. The floor surface has controlled anti-static properties (surface resistance 10⁶-10⁹ Ω) to prevent electrostatic discharge damage to sensitive electronic equipment.

KITOZER offers all-steel anti-static floors (HPL/PVC finish), ventilated floors, aluminum alloy floors, calcium sulfate floors, and OA network flooring. Standard panel size: 600mm×600mm. Load ratings range from CQ (light) to CR (heavy).

2. History

Raised floors originated in 1960s America alongside early mainframe computers. IBM 360-series machines required massive cable management and ESD protection. The 600mm×600mm standard emerged in the 1970s. China began importing raised floor systems in the 1980s-1990s, and domestic manufacturing rapidly matured by the 2000s. KITOZER, backed by Guangzhou Lian, now produces a full range from steel to aluminum and calcium sulfate floors.

3. Working Principles

3.1 Anti-Static Mechanism

Human activity generates electrostatic voltages up to several thousand volts, enough to destroy CMOS chips. Anti-static floor surfaces contain conductive materials (carbon black, metal fibers) that bleed static charge slowly. Surface resistance is controlled at 10⁶-10⁹Ω (anti-static) or 10⁴-10⁶Ω (conductive). Floors ground through pedestals to building grounding.

3.2 Plenum Space

The raised plenum (150-500mm) houses: power and data cables, underfloor air conditioning supply, fire pipes, water leak detection, and grounding busbars.

3.3 Structural Mechanics

Each 600×600mm panel is supported at four corners by height-adjustable steel pedestals anchored to the subfloor. Panels rest on stringers connecting adjacent pedestals. Typical load: 300-500kg concentrated, 3500-8000kg/m² uniformly distributed.

4. Technical Specifications

Parameter All-Steel HPL All-Steel PVC Aluminum Calcium Sulfate
Size (mm) 600×600 600×600 600×600 600×600
Thickness (mm) 35 35 35 38
Concentrated load (kg) 300-500 300-500 400-800 400-600
Uniform load (kg/m²) 3500-5000 3500-5000 5000-8000 4500-6000
System resistance (Ω) 10⁶-10⁹ 10⁶-10⁹ 10⁶-10⁹ 10⁶-10⁹
Fire rating B1 B1 A B1
Weight (kg/panel) 11.5 11.5 8.5 13.5

5. Classification and Selection

5.1 All-Steel Anti-Static Floor

Economical choice. Steel shell welded, filled with cement foam. HPL or PVC finish. Good load capacity, moderate price. Standard for general computer rooms.

5.2 Aluminum Alloy Floor

Die-cast aluminum, lightweight, corrosion-proof, recyclable. Higher cost but ideal for cleanrooms and hospitals.

5.3 Calcium Sulfate Floor

Eco-friendly formaldehyde-free core. Good flatness and comfort. Preferred for green offices and control rooms.

5.4 OA Network Floor

Low-profile (50-150mm) semi-steel floor for office cable management without full raised floor height.

5.5 Ventilated Floor

Perforated panels with 25-50% open area for underfloor air distribution in data centers.

6. Installation

Prepare subfloor (flatness ≤2mm/2m). Mark layout. Install pedestals on centers, anchor with adhesive or expansion bolts. Adjust height with laser level. Lay stringers. Place panels starting from center or wall. Gap ≤1mm. Ground all pedestals to copper busbar. Test: surface levelness ≤2mm/m, adjacent panel height diff ≤0.5mm, system resistance 10⁶-10⁹Ω.

7. Maintenance

Clean with damp mop (avoid flooding). Apply anti-static wax quarterly (never use ordinary wax—it insulates). Inspect monthly for loose panels and worn finish. Replace damaged panels using suction cup. Never drag heavy objects directly on floor.

8. FAQ (60 Questions)

Q1: What makes anti-static floor different?
A: Controlled surface resistance (10⁶-10⁹Ω) bleeds static; ordinary floors accumulate damaging charges.

Q2: Standard size?
A: 600×600mm globally. Custom sizes available at premium.

Q3: Raised height?
A: Offices 150-200mm; data centers 300-500mm. Depends on cable and AC requirements.

Q4: HPL vs PVC finish?
A: HPL is more durable and scratch-resistant (10+ years). PVC has comfort feel but wears faster. Data centers recommend HPL.

Q5: Load capacity?
A: 300-500kg concentrated; 3500-8000kg/m² uniform. Choose CR rating for heavy loads.

Q6: Can water pipes run under floor?
A: Not recommended. If unavoidable, install water leak detection.

Q7: How to replace a panel?
A: Use suction cup to lift straight up. Lower replacement into position.

Q8: Squeaking when walking?
A: Pedestals not leveled or stringers loose. Re-adjust and tighten.

Q9: Must floors be grounded?
A: Yes. Each pedestal bonds to copper busbar. Ground resistance ≤1Ω (shared) or ≤4Ω (isolated).

Q10: Can server racks sit on floor?
A: Yes, but racks should have bases distributing load across multiple pedestals.

Q11: How to choose ventilated floor?
A: Based on heat load. 25-50% open area for hot/cold aisle containment.

Q12: Steel vs calcium sulfate eco-friendliness?
A: Calcium sulfate is formaldehyde-free. Steel with cement foam is also low-emission.

Q13: Why is aluminum expensive?
A: Material cost is high, but aluminum is light, rust-proof, recyclable—reasonable lifecycle cost.

Q14: Installation labor cost?
A: $5.6-11/m² including pedestals and laying.

Q15: KITOZER pricing?
A: All-steel HPL: $25-39/m². PVC: $28-42/m². Aluminum: $49-77/m². Calcium sulfate: $35-53/m².

Q16: Warranty?
A: 5 years. Finish lasts 8-10 years; steel structure 20+ years.

Q17: Humid environments?
A: Use galvanized or aluminum pedestals to prevent rust.

Q18: Waxing?
A: Must use anti-static wax. Ordinary wax creates an insulating layer.

Q19: How to test anti-static performance?
A: Surface resistance meter. Electrode on floor surface; reading should be 10⁶-10⁹Ω.

Q20: Reusable?
A: Yes. Steel structure lasts 20+ years and can be relocated.

Q21: OA floor vs raised floor?
A: OA is low (50-150mm) for offices. Raised is high (200-500mm) for data centers.

Q22: Fiber optic under floor?
A: Yes, in metal conduit. Separate from power cables.

Q23: Wall-edge gaps?
A: Use edge trim or L-angle steel. Cut panels with diamond cutter.

Q24: Fire rating?
A: All-steel B1; aluminum A (non-combustible).

Q25: Panels for 100m² room?
A: 100/0.36 ≈ 278 panels + 5% waste = ~292.

Q26: Door height requirement?
A: At least 20mm above raised height. For 300mm raised, door ≥320mm.

Q27: Rolling chairs?
A: Yes, but chair feet need soft pads. Hard casters scratch HPL.

Q28: Uneven load consequences?
A: Panel deformation and collapse. Add pedestals or bases under heavy equipment.

Q29: KITOZER lead time?
A: Standard: 3-7 days. Custom: 10-15 days.

Q30: Underfloor air distribution?
A: Controlled by ventilated floor open area. Ventilated at racks, sealed elsewhere.

Q31: Standards?
A: SJ/T 10796-2020 anti-static raised floor; GB 50174 data center design.

Q32: Pedestal material?
A: Galvanized steel, height-adjustable. Heavy-duty uses thicker pedestals.

Q33: Worn finish?
A: Minor wear: re-wax. Severe: replace finish or entire panel.

Q34: Drilling holes in floor?
A: Not recommended. Use dedicated outlet panels instead.

Q35: AC ducts under floor?
A: Yes, underfloor plenum is primarily for air supply.

Q36: Dry winter static?
A: Maintain 40-60% humidity. Apply anti-static wax. Verify grounding.

Q37: Custom orders?
A: Yes—custom colors, sizes, ventilation rates, pedestal heights.

Q38: Wall repair after removal?
A: Edge trim leaves marks. Repair wall skirting after floor removal.

Q39: Health effects?
A: None. Anti-static voltage is tens of volts, far below human perception.

Q40: Contact KITOZER?
A: Guangzhou Lian Intelligent Systems Development Co., Ltd. Tel: +86 18520668845 / +86 13922289957. Websites: lain.com.cn / gdlain.com.

Q41-60: Additional FAQs cover cleaning products, pedestal spacing, firestopping, rack base coordination, ventilation ratio calculation, calcium sulfate vs steel comparison, cleanroom floor selection, hospital OR floors, laboratory floors, ESD testing frequency, disassembly procedures, old floor refurbishment, export packaging, installation qualifications, underfloor lighting, monitoring integration, smart floor sensors, environmental certifications, volume discounts.

9. Applications

9.1 Data Centers

Primary application. 300-500mm raised plenum for underfloor cooling and cable management. KITOZER has supplied all-steel HPL floors to multiple data center projects.

9.2 Computer Rooms

Enterprise server rooms, control centers, dispatch centers use anti-static floors to protect IT equipment.

9.3 Cleanrooms

Electronics manufacturing and pharmaceutical cleanrooms use stainless pedestals with aluminum floors for easy cleaning.

9.4 Hospital Operating Rooms

Operating rooms use anti-static PVC flooring to prevent electrostatic shock during surgery.

10. Price Reference

Product Spec RMB USD
All-steel HPL floor 600×600×35mm 180-280/m² $25-39/m²
All-steel PVC floor 600×600×35mm 200-300/m² $28-42/m²
Aluminum floor 600×600×35mm 350-550/m² $49-77/m²
Calcium sulfate floor 600×600×38mm 250-380/m² $35-53/m²
Ventilated floor 25% open 300-450/m² $42-63/m²
OA network floor 500×500×28mm 120-180/m² $17-25/m²
Pedestal system incl. stringers 40-80/m² $5.6-11/m²

11. KITOZER Advantages

  • In-house manufacturing from steel stamping to finish lamination
  • CR-grade load capacity
  • HPL finish rated for 10+ years wear
  • Galvanized pedestals for corrosion resistance
  • 5-year warranty, 20-year structural life
  • Selection and installation engineering support

12. Contact Us

Company: Guangzhou Lian Intelligent Systems Development Co., Ltd. (KITOZER brand)

Address: Chaotian Park, Zhongrun Industrial Zone, No. 5 Huashan Road, Shilou, Panyu, Guangzhou, China

Tel/WeChat: +86 18520668845 / +86 13922289957

WhatsApp: +1 906-853-4140

Chinese website: lain.com.cn

English website: gdlain.com

Scroll to Top