ToggleProduct Overview
The KITOZER 100A automatic transfer switch is a motorized mechanical changeover device that automatically transfers a three phase load between the preferred utility source and an emergency generator source. Unlike static transfer switches that use semiconductors, the ATS uses a robust motor-driven contactor assembly with a defined transfer time of typically 100 milliseconds to 250 milliseconds, which is acceptable for loads backed by UPS systems or for loads that can ride through brief interruptions. The KITOZER 100A ATS is built as a prewired assembly in a ventilated metal cabinet, including the changeover contactor, the programmable controller, metering instruments, and a manual operating handle. It is widely used in small to medium commercial buildings, retail centers, factory backup power panels, and generator set packages.
Technical Specifications
Rated current is 100A continuous at 40 degrees Celsius, three phase four wire 400V nominal, 50 Hz or 60 Hz. The changeover mechanism is a motor-driven four-pole contactor with electrically and mechanically interlocked positions, ensuring that the two sources can never be connected in parallel. Transfer time is 100 to 250 milliseconds depending on controller delay settings. Source sensing includes true RMS voltage measurement on all phases of both sources, with programmable under voltage, over voltage, under frequency, and over frequency thresholds. The controller provides adjustable engine start delay (typically 0 to 30 seconds), generator warm-up delay before load transfer (typically 0 to 60 seconds), and cool-down run-on time after return to utility (typically 0 to 30 minutes). Front panel LCD displays source voltage, load current, generator run hours, and the current source position. Communication ports include RS485 Modbus RTU as standard and an optional Ethernet card for Modbus TCP and SNMP. Dry contacts include source fail, generator start, generator stop, on generator, on utility, and general alarm. Manual operating handle allows the operator to force the contactor to either source or off position. Operating temperature range is minus 5 to plus 40 degrees Celsius, protection rating IP30 for indoor installation. CE marked and tested to IEC 60947-6-1 standard.
Applications
The 100A ATS is commonly installed as the generator interface for 80 kVA to 125 kVA diesel generator sets in commercial buildings, office towers, retail supermarkets, small data halls, hospital backup panels, and school standby power systems. It is also used in remote telecom sites where a solar or wind generator supplements the utility feed, and in marine and shore power installations. In many projects the ATS is paired with an upstream UPS so that the 100 to 250 millisecond mechanical transfer time is fully covered by the UPS battery, and the ATS only handles the bulk load of air conditioning, lighting, and receptacles. The unit is also suitable for use as a manual changeover switch in emergency maintenance situations.
Advantages and Features
The KITOZER 100A ATS provides a cost-effective transfer solution for loads that do not require sub-cycle switching. The motorized contactor has a rated electrical and mechanical life of tens of thousands of operations, and the mechanism is designed for simple inspection and contact maintenance. The controller is fully programmable through the front panel keypad, and the settings are stored in non-volatile memory so that they survive power loss. The unit includes a built-in exercise function that can start the generator and transfer the load for a short test period on a weekly schedule, which is important for keeping diesel generators healthy. The RS485 and optional Ethernet communication allows the ATS status to be integrated into building automation and remote monitoring platforms. A compact footprint and side-by-side mounting option make the unit easy to fit into existing generator switchboard lineups. The mechanical interlock between the two source positions is redundant with the electrical interlock, providing a fail-safe transfer design.
Installation and Maintenance Recommendations
Mount the ATS cabinet on a solid wall or rack and route the two source cables and the load cable through the bottom gland plate. Terminate copper conductors with lugs and torque to the nameplate value. Verify that the generator start and stop contacts match the generator controller voltage rating before connecting. During commissioning, run a full utility-fail test, a generator-fail test, and a manual transfer test, and verify that all alarm contacts behave as expected on the monitoring system. Preventive maintenance on an annual schedule includes inspecting the contactor contacts for wear, checking the motor mechanism for smooth operation, cleaning ventilation filters, and testing the generator exercise cycle. The contactor contacts are replaceable as a spare part, and the controller board is field swappable. KITOZER provides a two year warranty on the ATS and keeps regional stock for fast replacement.
Price
From $860 per piece. Contact KITOZER for factory pricing, lead time, and customization options including higher current ratings, different enclosures, or communication protocol upgrades.