KITOZER
KITOZER

KITOZER ATS 100A Automatic Transfer Switch For Generator

The KITOZER 100A automatic transfer switch (ATS) cabinet seamlessly switches critical loads between utility power and a standby diesel or natural gas generator. Housed in a wall- or floor-mounted IP54 steel cabinet, the ATS uses a motorized double-throw contactor with mechanical and electrical interlock, preventing the generator and utility from ever being connected in parallel. The built-in controller monitors utility voltage, frequency, and phase rotation; when mains fails beyond programmable limits, it starts the generator, waits for stable voltage, then transfers the load. When utility returns, it transfers back and stops the generator after a cool-down run.

Technical Specifications

Rated current 100A, 400V three-phase four-wire, 50Hz. Switch type: motorized double-throw contactor, mechanical and electrical interlock. Transfer time: 100 to 500 milliseconds programmable. Controller: digital ATS controller, LCD, voltage and frequency monitoring, programmable delay, Modbus RS485. Inputs: utility voltage, generator voltage, generator start. Outputs: transfer command, common alarm, generator start. Cabinet: IP54, powder-coated steel, wall or floor mount. Circuit breaker: 125A incoming breakers optional. Dimensions 600 x 400 x 800 mm.

Key Advantages

The ATS eliminates manual intervention during outages, ensuring critical loads such as lighting, refrigeration, and security systems stay powered. The motorized contactor is rated for tens of thousands of operations, far exceeding solenoid-type switches. Programmable time delays prevent nuisance transfer during momentary voltage sags. Modbus monitoring integrates the ATS with BMS or remote management. KITOZER pre-wires and factory-tests each cabinet before shipment.

Applications

Typical uses include small shops, offices, clinics, and residential backup systems paired with 20 to 50 kW generators. Telecom base stations, water pumping stations, and security systems rely on ATS for unattended operation. Rental and construction sites use ATS to switch between grid and generator without manual reconnection. Restaurants, convenience stores, and small factories protect refrigeration and production equipment from outage.

Installation and Maintenance

Mount the ATS near the main distribution board, with clear access to terminals. Connect utility input, generator input, and load output with correctly sized copper cables. Wire the generator start signal to the ATS controller. Set voltage pickup, dropout, and transfer delay according to site requirements. Test under simulated mains failure before handover.

Maintenance: inspect contacts and terminals every 12 months, test transfer function annually, keep cabinet clean and dry. KITOZER recommends logging every transfer event for maintenance records.

The ATS controller continuously monitors both source voltages, frequency, and phase rotation. When the preferred source fails beyond programmable pickup thresholds, the controller initiates generator start, waits for stable voltage and frequency, then transfers the load through the motorized switch. When the preferred source returns and remains stable for a settable delay, the controller transfers back and stops the generator after a cool-down run. Mechanical and electrical interlocks guarantee that both sources can never be connected simultaneously, protecting utility workers and the generator. Dry contacts provide remote alarm status and generator start signal for integration with building management systems.

Why Choose KITOZER

KITOZER electrical panels are built to industrial standards, using reputable brand breakers, controllers, and contactors. Each cabinet is pre-wired, factory-tested with primary injection, and supplied with wiring diagrams and test reports. The engineering team can customize protection settings, communication protocols, and panel layout to match site switchgear. KITOZER provides a 12-month warranty, technical documentation in English, and remote commissioning support for international projects.

Packaging and Shipping

The electrical cabinet is packed in a fumigated plywood crate with foam protection on the controller and circuit breaker face. KITOZER factory-tests each cabinet with primary injection and functional checks before shipment. Export documents include CE certificate, factory test report, wiring diagram, commercial invoice, packing list, and origin certificate. KITOZER can arrange CIF delivery and engineer supervision during site energization.

Quality Assurance and Warranty

Every KITOZER product undergoes a strict factory inspection process before shipment. The engine is run in and load-tested, the alternator winding resistance and insulation are measured, the control panel is functionally checked, and the complete set is operated under load bank for at least one hour. KITOZER provides a 12-month warranty from shipment or 1000 running hours, whichever comes first, covering manufacturing defects in engine, alternator, and control panel. Spare parts, filters, belts, and fuses are stocked for rapid dispatch. The KITOZER technical team provides remote troubleshooting support over email, WeChat, or WhatsApp, and can dispatch an engineer to site for critical projects.

KITOZER engineering can tailor the set to specific site conditions: cold climate kits with jacket water heater, oil pan heater, and battery blankets; tropical kits with larger radiator and desert-grade air filters; coastal kits with C5-M paint and anti-corrosion anodes; and emission-compliant kits for regulated markets. The factory also offers extended warranty, annual service contracts, and remote monitoring subscriptions that stream runtime, fuel level, and alarms to a cloud dashboard.

Price

From $1,800 per unit for the 100A ATS cabinet. Contact KITOZER for controller brand and communication options. Tel/WeChat: +86 13922289957.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart