KITOZER ATS: 400A Automatic Transfer Switch Generator

Product Overview

The KITOZER 400A automatic transfer switch is a floor-standing, heavy-duty changeover assembly designed for industrial and large commercial backup power systems. It automatically switches a 400A three phase load between the utility source and a diesel generator source whenever the utility voltage or frequency moves outside a programmable window. The unit uses a motorized four-pole contactor with electrical and mechanical interlocks, and it integrates a sophisticated controller with generator start sequencing, warm-up delay, cool-down run-on, and weekly exercise testing. The cabinet is prewired at the factory and tested under load before shipment, so the installer only needs to land the source and load cables and configure the parameters.

Technical Specifications

Rated current is 400A continuous at 40 degrees Celsius ambient, three phase four wire 400V nominal, 50 Hz or 60 Hz. Short time withstand is 25 kA for one second. The changeover mechanism is a motor-driven four-pole contactor with double break contacts, electrically and mechanically interlocked. Transfer time is 100 to 300 milliseconds depending on the controller delay. Source sensing is true RMS on all phases of both sources, with fully programmable under voltage, over voltage, under frequency, and over frequency thresholds. The controller provides generator start delay, warm-up delay, cool-down run-on, and weekly exercise schedule settings. A color touchscreen HMI displays source voltage, load current, power, generator run hours, transfer count, and event log. Communication includes dual Ethernet for Modbus TCP and BACnet IP, isolated RS485 Modbus RTU, and up to 12 Form C dry contacts. Cooling is natural convection for 400A rating. Enclosure is floor standing IP32 with bottom cable entry. CE marked and tested to IEC 60947-6-1.

Applications

The 400A ATS is used in large commercial building backup power panels, in hospital central emergency power systems, in data center utility-to-generator ties, in factory main distribution boards, in shopping mall emergency bus sections, and in water and wastewater treatment plants. It is typically matched with a 350 kVA to 500 kVA diesel generator set. In data center projects the ATS is often placed downstream of a static transfer switch or as a backup for critical loads that do not require sub-cycle transfer. The unit is also suitable for coastal and industrial environments where a robust mechanical contactor is preferred over a semiconductor solution for long-term unattended operation.

Advantages and Features

The KITOZER 400A ATS offers a lower acquisition cost than an equivalent static transfer switch while still providing automatic, unattended source switching. The mechanical design is simple to understand and easy for local electricians to service. The controller logs the last 1000 events with timestamp and source condition, which is useful for compliance reporting and for diagnosing nuisance transfers. The weekly exercise function ensures that the generator starts and runs under load at least once a week, preventing fuel stabilization issues and wet stacking. The Ethernet and serial communication ports allow the ATS to be integrated into building management systems and remote monitoring platforms. The manual operating handle provides a mechanical means to force the contactor to either source during maintenance. The double break contacts provide visible isolation when the contactor is in the off position, which is an important safety feature for maintenance crews working on downstream equipment. The unit also includes a programmable transition delay between sources, which can be set to allow the generator to stabilize fully before the load is transferred, and a re-transfer delay that prevents chattering when the utility source returns with marginal voltage. The controller also logs generator run hours and starts, which is useful for scheduling oil changes and filter replacements based on actual usage rather than calendar intervals. A battery-backed real-time clock ensures that event timestamps remain accurate even during extended power outages.

Installation and Maintenance Recommendations

Install the cabinet on a level concrete floor or equipment plinth with adequate front and rear working clearance. Route the utility and generator source cables and the load cable through the bottom gland plate and terminate on the labeled busbars. Verify that the generator start and stop relay contacts match the generator controller voltage and current ratings. During commissioning, perform insulation resistance tests, phase rotation checks, a full utility-fail transfer test at 50 percent and 100 percent load, and a communication integration test. Preventive maintenance on a semiannual schedule includes inspecting contacts, checking the motor gear mechanism, tightening busbar connections, and testing the weekly exercise cycle. The contactor contacts are field replaceable, and KITOZER recommends keeping a contact kit on site for critical installations. The controller board is hot swappable through the front panel. A five year warranty is available as an extended option.

Price

From $4,280 per piece. Contact KITOZER for firm quotation, general arrangement drawings, and factory acceptance test options for 400A class automatic transfer switches.