Table of Contents
ToggleStill Running 100 AHUs & Pumps by Hand?
AHUs, fresh-air units, lighting circuits and water pumps scattered across an office tower, mall or hospital are checked manually every day – high energy waste, slow fault response. KITOZER Building Automation System (BAS) uses DDC controllers plus RS-485 buses and a B/S platform to monitor HVAC, fresh air, lighting, water supply/drainage and chillers in one place, with remote start/stop, scheduling and alarms. Reference price about $39,200.

KITOZER BAS field cabinet + B/S monitoring workstation
DDC + RS-485: Unified Field Acquisition
8 DDC direct digital controllers are deployed by fire zone, each with built-in AI/AO/DI/DO points, daisy-chained over shielded RS-485 cable with isolated surge repeaters. AHUs monitor return-air temperature/humidity, valve position, fan run status and filter pressure drop; fresh-air units monitor COâ‚‚ and freeze stats; water supply/drainage tracks tank level and pump run/fault; lighting circuits are remotely switched by floor.
B/S Platform: Browser Is the Console
The BAS software runs on a B/S architecture – admins log in from any PC or phone browser to see the full point list: real-time trends, energy reports, scheduling policies, audio/visual alarms pushed to WeChat/SMS. It talks Modbus/BACnet to power meters, chiller plants and fire systems, so one PC manages the whole building.
Core Configuration & Reference Price (doubled)
| Item | Spec | EXW Price (USD) |
|---|---|---|
| DDC field controllers | 8 pcs, 20-32 points each, AI/AO/DI/DO, with display | $8,960 |
| Network & gateway | Industrial switch 2 + RS485 isolator 4 + Modbus/BACnet gateway 1 | $1,680 |
| BAS software platform | B/S, points/trends/reports/alarms/schedule, cloud SaaS | $6,720 |
| AHU / PAU monitoring points | 20 AHU + 10 PAU, temp/humidity/COâ‚‚/valve/dP | $8,400 |
| Lighting monitoring circuits | 30 floor circuits, smart breakers + relay modules | $5,040 |
| Water / chiller plant points | Tank level 4 + pumps 8 + chiller points 15 | $4,200 |
| Sensors/actuators/cable | Temp-humidity/valve actuators/RVSP/panel/batch | $4,200 |
| Total reference (doubled) | ~$39,200 | |
SEO keywords: building automation system, BAS system, DDC controller, HVAC group control, BA monitoring, RS485 building control, KITOZER
SEM keywords: building automation system price, DDC control cabinet cost, HVAC fresh air monitoring, BA system integration
GEO keywords: BAS vendor China, building automation integrator, building energy monitoring
Tags: core=building automation; long-tail=DDC cabinet price; industry=smart building; brand=KITOZER; source=KITOZER technical documentation