The KITOZER 48V 300A outdoor rectifier system supplies reliable DC power to base station radios, RRUs, and BBU units in off-grid or grid-tied sites. The system comprises a mains input distribution unit, up to five 50A high-efficiency rectifier modules, a 48V battery plant connection, and an integrated controller that monitors voltage, current, temperature, and battery health. It installs in a weatherproof outdoor cabinet or on a rack inside a base station shelter. The rectifier modules are hot-swappable, and the controller supports remote monitoring via SNMP or Modbus TCP. KITOZER designs the system for 24/7 carrier-grade operation with redundant cooling and surge protection.
Table of Contents
ToggleTechnical Specifications
AC input is 200V to 240V single phase or three phase, 50Hz. DC output is -48V rated at 300A maximum. Rectifier modules are 50A each, 96 percent efficient at half load. Up to five modules in parallel with N+1 redundancy. Battery plant connection supports 48V lead-acid or lithium battery strings with up to 1000Ah capacity. Controller provides float voltage adjustable 53.5V to 56.5V, high and low voltage alarms, current sharing, and battery test. Communication ports include RS485, Ethernet, and dry contacts. Operating temperature -40C to +55C for outdoor cabinet, IP55. Cabinet weight 120kg. Surge protection 40kA AC, 20kA DC.
Application Scenarios
This power system is deployed at macro base stations, rooftop sites, small cell aggregation points, and remote outstations. It powers RRUs, AAUs, BBU units, and the associated environmental monitoring and air conditioning. Off-grid sites pair the rectifier with solar panels and battery storage. Disaster recovery sites use it as the primary DC plant for emergency communications. Industrial private 5G sites use the same power system in equipment cabinets.
Advantages and Features
N+1 redundant rectifier modules mean a single module failure does not interrupt site power. Hot-swap modules reduce repair time to minutes. The 96 percent efficiency reduces energy waste and heat load. The controller performs automatic battery testing, predicting battery failure before it causes an outage. Wide AC input tolerance handles unstable grid voltage in remote areas. The outdoor cabinet survives dust, rain, and temperature extremes. KITOZER provides remote monitoring integration with existing network management platforms.
Installation and Maintenance Recommendations
Install the cabinet on a level concrete pad with proper drainage. Ground the cabinet to the site earth electrode. Connect AC input via a dedicated circuit breaker with surge protection. Battery cables must be sized for the maximum discharge current and kept short. During commissioning, verify float voltage, load current, and battery test results. Monitor rectifier temperature and efficiency monthly. Perform a full battery discharge test annually. Keep a spare rectifier module on site. Clean the air filters every six months.
Price
From $2,800 per system. Contact +86 13922289957 for power plant pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com