ToggleProduct Overview
The KITOZER Basic PDU with twelve output outlets and a 16A rated current is a vertical 0U power distribution strip built for standard 42U server cabinets where horizontal rack space is scarce. The tall narrow chassis runs along the rear vertical rail, freeing every rack unit for servers and storage. A solid copper busbar distributes 16A of continuous single-phase current to twelve universally positioned outlets, and the integrated circuit breaker protects downstream wiring against overload. This model is a popular choice for small and medium data closets, telecom base stations, and industrial automation racks where equipment depth leaves no horizontal U-space for a 1U strip. The vertical form factor also simplifies cable management, because outlets face the rear of the rack and cords run straight down to cable managers instead of bending around horizontal strips.
Technical Specifications
Input voltage 100 to 240V AC, single phase, 50 or 60 Hz. Rated current 16A continuous. Twelve universal outlets arranged vertically, with outlets alternating sides to reduce cable crowding. Input connection IEC C20 with 3 meter cord, or hard-wired terminal block option. Overcurrent protection via 16A thermal magnetic circuit breaker with manual reset. Surge protection 2100 Joules optional. Mounting brackets fit either 19-inch or 23-inch racks, with adjustable depth for shallow and deep cabinets. Operating temperature 0 to 45 degrees Celsius. Chassis SPCC steel, black powder coat. Dimensions 44 mm x 44 mm x 850 mm. Weight 1.6 kg. CE, RoHS, IEC 60950 compliant. KITOZER brand, three-year warranty.
Applications
The vertical 12-outlet PDU is typically installed in 42U server racks hosting 1U and 2U servers, network switches, and storage arrays. It also fits well in outdoor telecom cabinets, cellular base station enclosures, and factory automation control cabinets where equipment depth leaves no horizontal U-space. System integrators use this model as a second PDU alongside a metered unit, providing redundant power feeds without additional rack units. In co-location cages, the vertical strip powers tenant-owned equipment while the facility supplies the upstream breaker. In industrial automation racks, the PDU powers PLCs, HMI panels, and safety relays, and the rugged chassis tolerates floor vibration that would loosen consumer-grade strips.
Key Advantages
The vertical 0U form factor preserves rack space for compute and network hardware. The 16A busbar supports higher density than 10A strips, allowing more servers per cabinet without splitting feeds. Front-facing outlets on alternating sides reduce cable clutter and improve airflow through the rear of the rack. The included circuit breaker trips before upstream breakers, simplifying fault isolation and preventing nuisance trips at the distribution panel. Heavy-duty steel brackets survive repeated rack installation and removal cycles without bending. The surge module protects connected IT loads from lightning and switching transients. The universal outlet layout supports international deployments without regional SKUs.
Installation and Maintenance
Fix the vertical mounting brackets to the rear vertical rail using M6 cage nuts. Route the input cord along the cabinet cable manager and terminate it to the rack breaker. Label each outlet according to the equipment it feeds. Do not exceed 80 percent of the rated 16A for sustained operation. Periodically verify outlet tightness and check breaker operation. Inspect the surge status LED annually. Clean the chassis and vents every six months. Because the unit has no moving parts or firmware, routine maintenance is limited to visual inspection and thermal scanning. Keep the input cord away from network cable bundles to reduce electromagnetic interference, and leave a service loop at the rack breaker for future moves.
Why KITOZER
KITOZER is manufactured by Guangzhou Laian Intelligent System Development Co., Ltd., a factory specializing in data center power distribution and cable support systems since the early 2000s. Every PDU and cable tray leaves the production line after 100 percent insulation testing, high-pot testing, and load verification. The engineering team supports custom outlet layouts, custom cord lengths, private labeling, and OEM projects for system integrators and distributors. Long-term spare parts availability, stable pricing, and English-speaking technical support reduce risk for international buyers who source mission-critical infrastructure. KITOZER products ship to over sixty countries and are installed in enterprise data centers, telecom sites, industrial plants, and commercial buildings.
Packaging and Lead Time
PDUs are packed in corrugated cartons with foam corners, and cable trays are bundled with steel strapping and wrapped in stretch film. Standard models ship from stock within 5 to 7 working days. Custom configurations require 15 to 25 working days depending on complexity. Delivery is arranged by sea, air, or express courier according to buyer preference. Pallet loads and full container loads are supported for project sites. Each shipment includes a packing list, test report, and installation manual in English. The sales team confirms lead time at order placement and tracks production milestones until dispatch.
Compliance and Certifications
KITOZER products carry CE and RoHS marks, and production follows ISO 9001 quality management procedures. PDUs are tested to IEC 60950 and IEC 62053 where metering is fitted. Cable trays are tested to IEC 61537 for load rating and dimensions. Full test reports, material certificates, and factory audit documents are available on request for infrastructure projects that require submittal packages. The factory supports third-party inspection before shipment for large orders.
Price
From $78/pc. Contact +86 13922289957 for bulk pricing and custom outlet configuration.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com