KITOZER Basic PDU: 6 Outlet 10A Horizontal Rack Power Strip

Product Overview

The KITOZER Basic PDU with six output outlets and a 10A rated current is a cost-effective horizontal power distribution strip designed for small server cabinets, network racks, and edge computing enclosures. Built around a rugged steel chassis and a solid copper busbar, this entry-level PDU delivers clean and reliable mains power to entry-level servers, switches, routers, and storage appliances. Unlike ordinary consumer-grade power strips that use thin internal wire and plastic housings, the KITOZER basic PDU uses screw-terminated input wiring, a thermal-disconnect surge suppression module, and individually retained outlet modules that prevent accidental disconnection during rack vibration and cable management changes. The slim 1U profile fits into dense 19-inch racks while leaving every remaining rack unit available for compute and network equipment. This model is a standard choice for system integrators who need a dependable, no-frills power strip that ships worldwide without regional SKU complexity.

Technical Specifications

Input voltage 100 to 240V AC single phase at 50 or 60 Hz, auto-sensing. Rated current 10A continuous with 16A peak short-time withstand. Six universal output outlets accept IEC C13, NEMA 5-15R, Schuko, BS1363, and other regional plug types. Surge protection rating 1500 Joules with thermal disconnect and front-panel OK LED. Cord length 3 meters with IEC C14 inlet, or hard-wired terminal block option. Mounting flange supports both 1U horizontal rack installation and wall mounting with optional L-bracket kit. Operating temperature 0 to 45 degrees Celsius. Storage temperature minus 20 to 70 degrees Celsius. Humidity range 5 to 95 percent non-condensing. Chassis made of SPCC cold-rolled steel with black powder coating. Dimensions 483 mm x 44 mm x 45 mm. Weight 0.85 kg. CE and RoHS certified. KITOZER brand with a three-year factory warranty covering defects in materials and workmanship.

Applications

This basic PDU is commonly deployed in small office network racks, classroom AV cabinets, industrial control panels, retail point-of-sale enclosures, and laboratory test benches. It is also suitable for wall-mounted equipment cabinets in CCTV surveillance rooms, access control systems, and building automation controllers. The universal outlet configuration allows international projects to ship a single SKU and use local IEC cords without changing the PDU model, which simplifies spare parts logistics for system integrators and contractors working across multiple regions. In branch office rollouts, the unit powers small switches, routers, and UPS modules from one strip, reducing the number of wall sockets required. In training laboratories, the 1U PDU provides a clean power source for bench instruments and prototype equipment without occupying valuable bench space.

Key Advantages

The copper busbar carries current with low temperature rise, avoiding the hot-spot failures that plague wire-internal power strips under sustained load. The surge module protects connected loads from lightning-induced transients and switch-mode power supply noise, and the thermal disconnect ensures that a worn surge module opens safely instead of catching fire. Each outlet accepts retention screws so C13 plugs lock into place, preventing accidental unplugging during maintenance or cable changes. The slim 1U profile leaves rack space free for switches and patch panels. The transparent end covers allow quick visual inspection of wiring torques without tools. The universal outlet layout reduces spare parts inventory on international projects, and the steel chassis survives repeated installation and removal cycles without bending or cracking.

Installation and Maintenance

Mount the PDU using the included rack screws in a 19-inch rack, or fix it to a wall using the optional L-bracket kit. Route the input cord through cable managers to avoid strain on the IEC C14 inlet. Tighten output plug retention screws by hand and verify that no outlet is loaded beyond its rated current. Do not exceed 80 percent of the 10A rating for sustained operation, to leave headroom for inrush currents. Inspect the surge status LED annually; if the LED is off, replace the surge module. Clean the chassis with a dry cloth and keep ventilation gaps clear. Because the unit has no moving parts or firmware, routine maintenance is limited to visual inspection and annual thermal scanning. Label each outlet according to the connected equipment asset ID, so that troubleshooting during an outage takes minutes instead of hours.

Why KITOZER

KITOZER is manufactured by Guangzhou Laian Intelligent System Development Co., Ltd., a factory specializing in data center power distribution and cable support systems since the early 2000s. Every PDU and cable tray leaves the production line after 100 percent insulation testing, high-pot testing, and load verification. The engineering team supports custom outlet layouts, custom cord lengths, private labeling, and OEM projects for system integrators and distributors. Long-term spare parts availability, stable pricing, and English-speaking technical support reduce risk for international buyers who source mission-critical infrastructure. KITOZER products ship to over sixty countries and are installed in enterprise data centers, telecom sites, industrial plants, and commercial buildings.

Packaging and Lead Time

PDUs are packed in corrugated cartons with foam corners, and cable trays are bundled with steel strapping and wrapped in stretch film. Standard models ship from stock within 5 to 7 working days. Custom configurations require 15 to 25 working days depending on complexity. Delivery is arranged by sea, air, or express courier according to buyer preference. Pallet loads and full container loads are supported for project sites. Each shipment includes a packing list, test report, and installation manual in English. The sales team confirms lead time at order placement and tracks production milestones until dispatch.

Compliance and Certifications

KITOZER products carry CE and RoHS marks, and production follows ISO 9001 quality management procedures. PDUs are tested to IEC 60950 and IEC 62053 where metering is fitted. Cable trays are tested to IEC 61537 for load rating and dimensions. Full test reports, material certificates, and factory audit documents are available on request for infrastructure projects that require submittal packages. The factory supports third-party inspection before shipment for large orders.

Price

From $48/pc. Contact +86 13922289957 for OEM packaging, custom outlet layout, and factory lead time.