Table of Contents
ToggleProduct Overview
KITOZER VRLA battery cabinet is a heavy-duty steel enclosure designed to house valve-regulated lead-acid batteries for UPS and switchgear applications. The cabinet holds up to 32 pieces of 12V 100Ah batteries in a single string, providing approximately 384V DC bus at 100Ah capacity. It includes vented top, heavy-duty shelves rated for battery weight, front and rear access doors, and terminal bus bars. Optional temperature monitoring and smoke detection integrate with the site BMS. The cabinet is the safe, organized way to deploy VRLA batteries in data centers and industrial rooms.
VRLA batteries are heavy, typically weighing 30kg each, and require proper support and ventilation. A dedicated battery cabinet provides mechanical support, contains any leaking electrolyte, and maintains airflow to keep batteries at optimal temperature. The 32-piece string at 384V is a standard configuration for 30 to 60kVA UPS systems, providing 10 to 30 minutes of backup time depending on load. The cabinet keeps batteries organized and accessible for testing and replacement.
Technical Specifications
Capacity 32 x 12V 100Ah VRLA AGM or gel batteries, nominal DC voltage 384V. Cabinet construction 1.5mm steel, powder coated RAL 7035. Shelves rated 150kg per level. Top vent with fan option for temperature control. Front and rear perforated doors for airflow. Terminal bus bars with copper lugs. Grounding terminal. Optional smoke detector, temperature sensor, and BMS monitoring. Floor standing 800x600x2000mm. IP20. CE. KITOZER, 5 year warranty on cabinet.
The cabinet includes 4 shelves, each rated 150kg, supporting 8 batteries per level. Top vent includes a 100mm diameter opening for natural convection, with optional 120mm fan for forced ventilation. Front and rear doors are perforated for 60 percent open area, ensuring adequate airflow. Terminal bus bars are copper, sized for 100A continuous, with M8 studs for cable connection. Grounding terminal is 16mm2. The cabinet includes a lockable front door and a removable rear panel. Operating temperature range is 15 to 25 degrees Celsius for battery life.
Application Scenarios
Battery cabinets are used with UPS systems in data centers, server rooms, industrial control rooms, and telecom sites. They house the DC bus that supplies the UPS during utility outages. The cabinet keeps batteries organized, prevents unauthorized access, and contains any leaking electrolyte. In small and medium data centers, a single cabinet provides 10 to 30 minutes of backup time depending on UPS load. It is also used in solar storage and telecom off-grid installations.
Typical deployments include enterprise server rooms with 30 to 60kVA UPS, telecom central offices, and industrial plants with critical control systems. In hospitals, battery cabinets support UPS systems for operating rooms and intensive care units. In financial trading rooms, they ensure that trading continues during utility outages. The cabinet is also used in renewable energy installations, solar storage, and telecom off-grid sites. The 32-piece 384V configuration is a standard match for most mid-size online UPS systems.
Advantages and Features
The main benefit is safe, organized battery deployment. Heavy steel shelves support the weight of lead-acid batteries without sagging. Vented top and perforated doors allow natural convection, preventing heat buildup. Front and rear access simplifies cleaning and testing. Copper bus bars reduce connection resistance. Optional smoke and temperature monitoring gives early warning of battery faults. Lockable doors prevent unauthorized access. KITOZER cabinet ships fully assembled, saving installation time.
Additional benefits include robust construction, easy access, and integrated monitoring options. The 1.5mm steel construction ensures years of service without deformation. Front and rear doors allow maintenance from both sides, useful in tight rooms. Copper bus bars with M8 studs make cable connection straightforward. Optional smoke detector triggers an alarm before a battery fault escalates. Temperature sensor reports battery room temperature to BMS, ensuring optimal conditions. The cabinet is powder-coated for corrosion resistance.
Installation and Maintenance Recommendations
Place the cabinet on a level floor, near the UPS but with adequate clearance for heat. Do not install in direct sunlight or near heating vents. Install batteries on shelves from bottom to top, following the series connection diagram. Torque terminals to manufacturer specification. Verify insulation resistance before connecting to UPS. Keep the room temperature between 20 and 25 degrees Celsius for maximum battery life. Annual maintenance includes visual inspection, terminal torque check, internal resistance test, and cleaning of vents. Replace any battery with abnormal voltage or internal resistance.
For safe operation, ensure that the room has adequate ventilation, because VRLA batteries emit small amounts of hydrogen during charging. Keep the cabinet away from combustible materials. Use insulated tools when working on the DC bus. Label each battery with installation date and voltage reading. KITOZER recommends quarterly voltage checks and annual internal resistance testing. Replace batteries every 5 to 7 years depending on use. Keep a log of battery condition, and replace any battery that deviates from the string average by more than 0.1V.
Price
From $890 per empty cabinet. Batteries sold separately. Contact +86 13922289957 for battery cabinet with battery package pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com