Table of Contents
ToggleKITOZER KTR-BC Battery Charger / Floating Charging Cabinet
Brand: KITOZER Series: KTR-BC Category: Power Distribution 2 / Battery Charger
battery chargerfloating chargerDC charging3-stage chargingrectifier
1. Overview
KITOZER KTR-BC smart battery charger is a DC power device that charges battery banks and maintains them on float charge. UPS battery banks in datacenters, substation DC panels, and telecom backup batteries all connect to chargers: when mains is normal, the charger supplies the load and floats the battery; on mains failure, the battery discharges to the load, and the charger recharges it when power returns.
Charging is not just connecting a voltage. Battery charging has stages: bulk (high-current constant-current), equalization (constant-voltage high-current), and float (low-current trickle). KTR-BC automatically handles this: on power-on, it detects battery voltage, starts constant-current bulk charge if low, switches to float when full, and automatically returns to equalization if self-discharge drops the voltage — “3-stage smart charging.”
KTR-BC comes in wall-mount (5~20A, for telecom base stations and small rooms) and floor-standing cabinet (30~200A, for substation DC panels and datacenter battery rooms). Input: single-phase 220V or 3-phase 380V; output: DC48V/110V/220V. RS485/SNMP interfaces connect to the environment monitoring platform for remote voltage, current, charge status and fault alarms.
2. Key Features
3-stage smart charging
- Constant-current bulk → constant-voltage equalize → float, auto-switch.
- Temperature-compensated float voltage (adjusts for ambient temp).
- Periodic equalization (every 3 months) to prevent sulfation.
High-power rectification
- High-frequency switch-mode, efficiency ≥92%, PF ≥0.95.
- Modular rectifiers with N+1 redundancy; one module failure won’t stop the system.
- 3-phase input with balanced load, wide grid tolerance.
Protection & alarm
- Output over-voltage, over-current, short-circuit; battery reverse-polarity protection.
- Input over/under-voltage, phase-loss protection.
- RS485/SNMP for remote monitoring of voltage and current.
Battery management
- Charge current limit to prevent overcharge.
- Temperature compensation terminal with probe for auto voltage adjustment.
- History: charge cycles and fault logs for maintenance analysis.
3. Specifications
| Item | KTR-BC-4810 | KTR-BC-22030 | KTR-BC-220100 |
|---|---|---|---|
| Output | DC48V | DC220V | DC220V |
| Rated current | 10A | 30A | 100A |
| Input | 1-phase 220V | 3-phase 380V | 3-phase 380V |
| Charging | 3-stage | 3-stage+temp comp | 3-stage+temp comp+N+1 |
| Modules | Integrated | 30A×1 | 20A×6 (N+1) |
| Efficiency | ≥90% | ≥92% | ≥94% |
| Comm | RS485 | RS485+SNMP | RS485+SNMP+dry |
| Mount | Wall | Floor cabinet | Floor cabinet |
| Size (mm) | 300×400×150 | 600×800×2260 | 800×800×2260 |
4. Reference Prices
KTR-BC-4810 wall-mount small charger (DC48V/10A, 1-phase, 3-stage): Reference USD 210~560 / unit (ref. CNY 1,500~4,000 at ~7.2)
KTR-BC-22030/220100 floor-standing charger (DC220V, 30~100A, modular N+1, SNMP): Reference USD 2,080~11,100 / unit (ref. CNY 15,000~80,000 at ~7.2)
Reference only; final quote depends on output voltage, current, module redundancy, comm interfaces and cabinet size. Battery cables, temp probe and monitoring software billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter UPS battery room charging and maintenance.
- Substation DC operating power panels.
- Telecom base station backup battery float charge.
- Power and rail transit signaling DC systems.
- Solar/PV energy storage battery charging.
6. Installation & Maintenance
Installation
- Match output voltage to battery bank (48V/110V/220V).
- Size charge current at 0.1C~0.2C of battery capacity.
- Wall-mount: fix to wall; connect input and battery +/- terminals.
- Floor cabinet: position, anchor, wire 3-phase input; output to battery fuses.
- Install temp probe near battery; set compensation coefficient.
- RS485/SNMP to PE platform; set alarm thresholds.
- Power on; test bulk→float auto-switch and monitor voltage/current.
Maintenance
- Check float voltage periodically (2.25~2.30V/cell normal).
- Verify module fans running; clean air filters.
- Measure battery terminal voltage; balance if deviation >0.05V/cell.
- Conduct capacity discharge test quarterly to evaluate battery health.
- Verify comm interfaces; confirm alarm delivery.
7. FAQ
- Q: Float vs equalization?
A: Float is low-current maintenance (~2.25V/cell); equalization is high-current top-up (~2.35V/cell). New or long-idle batteries start on equalization, then switch to float. - Q: Why temperature compensation?
A: Battery charge voltage is temperature-dependent: high temp requires lower voltage (else overcharge/overheat); low temp requires higher voltage (else undercharge). Temp comp auto-adjusts. - Q: What is N+1 redundancy?
A: If 100A needed, install six 20A modules (120A total); one fails and 100A remains — system stays up. Modules hot-swappable. - Q: How does a charger relate to a UPS?
A: UPS has an internal charger; small UPS uses built-in charging. Large UPS battery rooms use a separate standalone charger for stable, high-capacity charging.
8. Trend & Selection
Smart chargers evolve from analog to digital control: trend is modular + digital — standard rectifier modules (20A/30A/50A), stacked on demand; monitoring to cloud with mobile app. As lithium replaces lead-acid, charge curves must be re-matched (Li-ion curves differ from lead-acid). Select by battery voltage and capacity; calculate charge current; wall-mount for small capacity, modular N+1 for large; always connect temp compensation; RS485/SNMP to PE platform; never skip annual capacity discharge tests — degradation is gradual and invisible without testing.
9. Delivery & Service
KITOZER provides charger selection: based on battery specs (voltage, capacity, cell count), we calculate charge current and module configuration. We produce the charging system diagram (input, output, battery connection, monitoring wiring). Bundled with battery banks, DC panels and PE monitoring. Delivery includes charger cabinet, rectifier modules, monitoring module, battery fuses and temp probe. Warranty covers module replacement and parameter tuning.
10. Additional Notes
The most common pitfall is “buying a smart charger but not connecting temp compensation.” The temp comp terminal is right on the terminal block — a single wire to the probe — but many installers skip it. Result: summer high temp, float voltage doesn’t drop, batteries overcharge, overheat and bulge; winter low temp, voltage doesn’t rise, batteries never fully charge. One wire — don’t skip it.
Another pitfall: no capacity discharge testing. The charger shows batteries “full,” but internally they may be sulfated and capacity-degraded. Normal float voltage does not equal normal capacity. At least annually: disconnect mains, discharge batteries to terminal voltage under load, and measure actual delivered capacity. If it’s 60% of rated, it’s time to replace. Skipping discharge tests means discovering battery failure only when mains actually drops — that’s an outage.
Selection summary: battery voltage determines output (48V/110V/220V); charge current at 0.1C~0.2C; small wall-mount integrated, large floor-standing modular N+1; always connect temp comp; RS485/SNMP remote monitoring; annual capacity discharge test. The charger is the battery’s caretaker — treat it well, and batteries perform when you need them.
SEO Information
Search keywords:battery chargerfloating chargerDC charging cabinetrectifier charger3-stage chargingbattery maintenanceKTR-BCKITOZER
SEM keywords:battery charger price, floating charging cabinet supplier, smart rectifier, DC panel charger,KTR-BC,KITOZER
GEO landing page:lain.com.cn/product/ktr-bc-battery-charger-floating-cabinet.html
Title:KITOZER KTR-BC Battery Charger / Floating Charging Cabinet
Meta Keywords:battery charger,floating charger,DC charging cabinet,rectifier charger,battery maintenance charger,KTR-BC,KITOZER
Meta Description:KITOZER KTR-BC smart battery charger with 3-stage charging (bulk/float), 3-phase input DC output, for UPS battery rooms, DC panels, substations and telecom base stations.
Anchor: KITOZER by Guangzhou Laian · Power distribution equipment
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com