The KITOZER battery energy storage fire suppression system is a multi-stage safety solution designed for lithium-ion battery cabinets and containers. It combines early gas and smoke detection, per-module aerosol or water-mist suppression, and post-fire cooling to prevent thermal runaway propagation and re-ignition. The system is engineered to meet modern standards for utility-scale and C&I battery energy storage installations. It addresses the specific hazards of lithium-ion batteries, which can vent flammable gas before visible smoke appears and can re-ignite long after the first flame is extinguished.
Table of Contents
ToggleProduct Overview
The KITOZER fire protection architecture includes a gas detection unit monitoring hydrogen, carbon monoxide, and voc levels inside each battery module, a smoke and heat detector at the cabinet level, a module-level aerosol or water mist cylinder, and a site fire alarm panel. On detection, the system triggers first-stage suppression within seconds, isolates the affected module, and sends an alarm to the site EMS and fire panel. Optional second-stage water mist provides long-duration cooling to prevent re-ignition.
The control panel is a 7-inch touchscreen that shows the status of every detector and cylinder, and it stores the last 500 events. The panel includes a battery backup that keeps detection active for 90 minutes after mains power loss. The detection loop is class B, supervised, so a broken wire or short circuit raises a trouble signal rather than going undetected. The system also interfaces with the battery BMS, so the BMS can disconnect the battery string when a gas alarm is raised.
Technical Specifications
Detection: H2 sensor 0 to 1000ppm, CO sensor 0 to 500ppm, photoelectric smoke, rate-of-rise heat. Suppression options: per-module aerosol 0.3L, per-cabinet water mist 10L, or container-level fluorinated ketone. Response time detection to discharge less than 5 seconds. Alarm outputs dry contact and Modbus TCP. Power supply 24V DC, backup battery 90 minutes. Operating temperature -20 to +60 degrees Celsius. Enclosure IP65. Certifications EN 12094, ISO 14520, GB 51048. KITOZER brand, 3-year warranty, cylinder inspection every 5 years.
Applications
This system is deployed in LFP and NMC battery cabinets for C&I storage, grid-scale storage containers, backup power rooms at data centers and telecom sites, and off-grid microgrids. It is suitable for new build projects and retrofits to existing battery rooms where code compliance and occupant safety are required. It is also used in battery exchange stations for electric two-wheelers, where packs are swapped frequently and thermal event risk is higher.
Advantages and Features
Multi-stage detection catches thermal abuse at the gas stage, before visible smoke appears, drastically reducing the chance of escalation. Per-module suppression limits damage to a single module instead of the whole cabinet. Aerosol agents leave no residue and require no piping, simplifying installation. Water mist post-fire cooling prevents re-ignition, which is a common failure mode of simple gas suppression. The system integrates with the battery BMS and site EMS, so alarms and interlocks are coordinated. A self-test function runs weekly without discharging the cylinders.
The system uses addressable detectors, so the control panel shows exactly which module or detector has triggered. The aerosol cylinders are non-pressurized cartridges that can be replaced in seconds. The water mist option uses deionized water, which avoids mineral deposits on electronics. The panel supports remote monitoring over Ethernet, so the site operator can see alarms from the office. The system also includes a manual release button and an abort switch, so trained responders can override automatic discharge during a false alarm.
Quality and Reliability
Every control panel undergoes a factory function test that exercises every detector loop, relay output, and printer port. The gas sensors are calibrated against certified test gas before shipment. The aerosol cylinders are pressure tested and dated. KITOZER provides a commissioning certificate and a user manual in English. Spare detectors, cylinders, and control panels are stocked at regional service partners. The system is designed to be maintained by a local fire protection contractor, with standard addressable loop protocols.
Installation and Maintenance
Install detectors at the top of each module and on the cabinet ceiling, where hot gases accumulate. Route detection cables in cable trays separate from power cables. Mount suppression cylinders close to the protected volume to minimize discharge pipe length. Commission with a certified fire protection contractor, including a full discharge simulation without releasing agent.
Maintenance monthly includes visual detector check, quarterly includes gas sensor calibration, and annually includes full system function test and cylinder weight check. Replace aerosol cylinders after activation or after 10 years, whichever comes first. Keep a log of all tests and replacements, because insurers and grid operators will request it. In dusty environments, clean detector heads quarterly to prevent false alarms.