KITOZER Battery Energy Storage Fire Suppression System

The KITOZER battery energy storage fire suppression system is a multi-stage safety solution designed for lithium-ion battery cabinets and containers. It combines early gas and smoke detection, per-module aerosol or water-mist suppression, and post-fire cooling to prevent thermal runaway propagation and re-ignition. The system is engineered to meet modern standards for utility-scale and C&I battery energy storage installations.

Product Overview

The KITOZER fire protection architecture includes a gas detection unit monitoring hydrogen, carbon monoxide, and voc levels inside each battery module, a smoke and heat detector at the cabinet level, a module-level aerosol or water mist cylinder, and a site fire alarm panel. On detection, the system triggers first-stage suppression within seconds, isolates the affected module, and sends an alarm to the site EMS and fire panel. Optional second-stage water mist provides long-duration cooling to prevent re-ignition.

Technical Specifications

Detection: H2 sensor 0 to 1000ppm, CO sensor 0 to 500ppm, photoelectric smoke, rate-of-rise heat. Suppression options: per-module aerosol 0.3L, per-cabinet water mist 10L, or container-level fluorinated ketone. Response time detection to discharge less than 5 seconds. Alarm outputs dry contact and Modbus TCP. Power supply 24V DC, backup battery 90 minutes. Operating temperature -20 to +60 degrees Celsius. Enclosure IP65. Certifications EN 12094, ISO 14520, GB 51048. KITOZER brand, 3-year warranty, cylinder inspection every 5 years.

Applications

This system is deployed in LFP and NMC battery cabinets for C&I storage, grid-scale storage containers, backup power rooms at data centers and telecom sites, and off-grid microgrids. It is suitable for new build projects and retrofits to existing battery rooms where code compliance and occupant safety are required.

Advantages and Features

Multi-stage detection catches thermal abuse at the gas stage, before visible smoke appears, drastically reducing the chance of escalation. Per-module suppression limits damage to a single module instead of the whole cabinet. Aerosol agents leave no residue and require no piping, simplifying installation. Water mist post-fire cooling prevents re-ignition, which is a common failure mode of simple gas suppression. The system integrates with the battery BMS and site EMS, so alarms and interlocks are coordinated. A self-test function runs weekly without discharging the cylinders.

Installation and Maintenance

Install detectors at the top of each module and on the cabinet ceiling, where hot gases accumulate. Route detection cables in cable trays separate from power cables. Mount suppression cylinders close to the protected volume to minimize discharge pipe length. Commission with a certified fire protection contractor, including a full discharge simulation without releasing agent. Maintenance monthly includes visual detector check, quarterly includes gas sensor calibration, and annually includes full system function test and cylinder weight check. Replace aerosol cylinders after activation or after 10 years, whichever comes first.

Price

From $1,850/cabinet protection. Contact +86 13922289957 for container-level fire protection design and code compliance review.